Download 660x Register-Level Programmer Manual
Transcript
Chapter 2 General-Purpose Counter/Timers Selected Gate Selected Source 0 Counter Value 2 1 3 1 2 3 3 HW Save Register 1 3 Figure 2-8. Buffered Period Measurement Buffered Pulse-Width Measurement Buffered pulse-width measurement is similar to single pulse-width measurement, but buffered pulse-width measurement takes measurements over multiple pulses. The counter uses the Selected Source to measure the pulse width of the signal present on the Selected Gate input, counting the number of rising edges that occur on the Selected Source while the Selected Gate remains in an active state. At the completion of each pulse-width interval for the Selected Gate, the HW Save or SW Save register latches the counter value for software read. An interrupt notifies the CPU after each period so that the interrupt software can read the value in the HW Save register. Figure 2-9 shows two pulse widths of a buffered pulse-width measurement in which the first pulse width is three Selected Source rising edges and the second pulse width is two Selected Source rising edges. The counter configuration is as follows: • Source: internal • Gate: external signal • Gate mode: level • Gate polarity: inverted • Second gate: selected gate • Second gate mode: on • Second gate polarity: inverted • Read from: determined by Gi DMA Status register • Interrupt on: DMA interrupt • Count once: false 660x Register-Level Programmer Manual 2-10 ni.com