[B15] SERIAL PORT 3 (Only in ACS/ACT System)
0
Closed
1
PC Communication
2
GSM MODEM
3
ERS
[B16] SERIAL PORT 4 (Only in ACS System)
0
Closed
1
PC Communication
2
GSM MODEM
3
ERS
[B17] HALL CALLS INHIBIT
0
Hall Calls Allowed
1
Hall Calls Inhibited
[B18] TWO DOORS SELECTION
Not Used
0
The parameters given in Floor Parameters section are valid for door selection at each floor.
Terminal Input
The door to be opened at each floor is determined by the programmable inputs, DOA and
1
DOB.
[B19] AFTER STOP FAILURE
Continue
0
System continues to work.
Clear Registers
1
All of the call registers are cleared and the system continues to work.
[B20] INSPECTION SPEED
Fast (Hydraulic)
0
Inspection speed is high speed. (Only in ACH System)
Slow
1
Only Direction
When there is a motion command in inspection mode then only direction command is sent,
2
neither slow nor high speed is activated.
[B21] THERMOMETER
0
No Temp. Control
1
Onboard Detector
2
THR Input
[B22] INSPECTION SWITCH
0
Closed contact in inspection mode.
1
Open contact in inspection mode.
[B23] PTC CONTROL
0
OFF
1
ON
F/7.5.5.02.67 R:10
34 / 62