Download PRESYNCHRO Tutorial/Reference Manual

Transcript
CRITICALS
CRITICALS
CRITICALS
6*<Critical Movement Number>
Defaults:
Menus/Groups:
6*0
[PARAMETERS] [SIGNAL2000]
The purpose of this command is to enter the movement which is critical for each phase of the
phase sequence of operation of the current intersection (for SIGNAL2000 file compatibility
only).
<Critical Movement Number> is the movement number designating the movement which
controls the design of the signal phase, and can be 0-12. Its default value is 0, no critical
movement.
Notes
•
Designation of a critical movement in any phase will result in that movement
appearing with asterisks in the phase movement diagram. This is normally used
to represent movements which were used to control a DESIGN. This diagram
appears as part of the DIAGRAMS, ANALYZE, EVALUATE and
QUEUECALCS reports. If a movement is designated as critical in any phase, the
line for that movement in the ANALYZE report is flagged with an asterisk in the
LOS column.
•
The TIMINGS command automatically implements a CRITICAL command for
the phases of the specified sequence which have been DESIGNed.
PRESYNCHRO
B-80
Reference