Chapter 2: INPUT REFERENCE STANDARD DESIGN INPUT DATA Specifies whether the input data for the Standard Design energy use is saved on disk. Note that the Standard Design building is created internally by MICROPAS. If saved, the file name extension is '.CBx' (x = current version number). The Standard Design input file can converted to a regular Micropas file (‘.MPx’) using the CONVERT INPUT FILES feature found under OTHER OPERATIONS. Since the Proposed Design is compared to the Standard Design, the printout of the Standard Design input file may be useful in figuring out how to bring difficult buildings into compliance. Legal values: 'Save' or 'NoSave'. Zone Figure 2-7. Zone Input Data 1> ZONE NAME ....................................... 2> CONDITIONED (Yes, No) ........................... 3> ZONE TYPE ....................................... 4> FLOOR AREA (sf) ................................. 5> VOLUME (cuft) ................................... 6> NUMBER OF DWELLING UNITS ........................ CREDITS 7> HOUSEWRAP/VERIFIED AIR LEAKAGE (Yes,No,SLA) ..... 8> RADIANT BARRIER (Yes, No, CoolRoof) ............. 9> VERIFIED INSULATION QUALITY (Yes, No) ........... HVAC SYSTEM 10> NUMBER OF SYSTEMS SERVING ZONE ................. 11> HEATING SYSTEM NAME ............................ 12> COOLING SYSTEM NAME ............................ 13> DUCT SYSTEM NAME ............................... 14> NATURAL VENTILATION SYSTEM NAME ................ 15> FAN VENTILATION SYSTEM NAME .................... 16> THERMOSTAT NAME ................................ HVAC SIZING 17> NUMBER OF PEOPLE/UNIT (occupants/unit) ......... Overview HOUSE Yes Residence 1600 12800 1 No Yes No 1 FURN.80 AC.13.0.TXV R6.0.TEST ONE.STORY None Setback 4 Compliance analysis for most residential buildings will treat the entire building as a single zone. Multi-zone buildings include buildings with attached sunspaces, controlled ventilated crawlspaces, zonally controlled HVAC systems and multiple HVAC systems. The CEC has approved methods for modeling multi-zone building energy features, which are described in Chapter 3, Advanced Topics. The discussion in this chapter assumes a single zone building. The ZONE Section specifies the size of the zone, the type of HVAC equipment that conditions the zone and other information related to the zone. There are two options and procedures for obtaining compliance credit for reduced building envelope air leakage. These credits require installation of an approved housewrap product or HERS verified testing the air infiltration of the constructed house with a blower door. © 2005 by Enercomp, Inc. 09/15/2005 COMPLIANCE 2-15