Transcript
Appendix D External GPIO Configuration Matrix Function # - Name Description Function #10 configures the connector for output mode. ICR 10 – ICR_OUT Selecting ICR function directs the Osprey device to drive the GPIO connector output with its Incoming Count Rate pulses. The ICR pulses are derived from the raw PHA energy events processed by the Fast Discriminator hardware and are not affected by the LLD/ULD window settings. The approximate ICR count rate can also be read by client applications through the Input_CountRate parameter. Multiple GPIO connectors can be configured for the ICR output function to extend the same output to multiple connectors Functions #11 through #16 configures the respective GPIO connector for output SCA1 11 – SCA1_OUT SCA2 12 – SCA2_OUT SCA3 13 – SCA3_OUT SCA4 14 – SCA4_OUT SCA5 15 – SCA5_OUT SCA6 16 – SCA6_OUT By selecting SCAn function on a GPIO connector, pulses from energy events that falls within an SCA's energy window and counted by the internal SCA counter, are also exposed external to the device through the designated GPIO connector. Selecting SCAn function on a GPIO connector makes the same pulses counted by the SCA counter available on that GPIO connector. The internal SCA counters can be read by the GetSCAbuffer command. The SCA energy windows can be set through the PutSCA definitions command and read through the GetSCA definitions command. Multiple GPIO connectors can be configured for other SCAn functions, or to the same SCAn function. There are no restrictions. These functions are not supported in Genie 2000. Function #17 configures the connector for input mode. The PHA EXT START/STOP IN function directs the GPIO connector to accept an external user-supplied signal to synchronize the start or stop of the Osprey's PHA acquisition. The Osprey supports both pulsed and level modes of external acquisition control. PHA EXT START/STOP IN 17 – PHAEXTSS_IN The PHA input's external start/stop logic must be enabled and configured for either pulsed (DSA2K) or level (Lynx) control mode through the Input_PhaExternalControlMode parameter. The pulsed mode behavior must be setup through the Input_PhaExternalControl parameter, and the polarity through the Input_PhaExternalControlPolarity parameter. The PHA EXT START/STOP IN function is limited to a single GPIO connector. Function #18 configures the connector for output mode. PHA EXT START/STOP OUT 100 18 – PHAEXTSS_OUT The PHA EXT START/STOP OUT function directs the Osprey device to drive the GPIO connector logic output with either a pulse or a level when the PHA Input acquisition status changes state. Osprey Universal Digital MCA Tube Base