0
8
1
1.0
0.0
Start Measurement (aM0!)
Port
Loc [ T_C
]
Mult
Offset
End (P95)
; Wait an additional minute before storing all
;
data in final storage. Any time discrepancies
;
between the two loggers is easily accomodated
;
by this timing.
22: If time is (P92)
1: 2
Minutes (Seconds --) into a
2: 15
Interval (same units as above)
3: 30
Then Do
; Store date/time, battery voltages, weather data
;
and soil moisture data in final storage
23: Do (P86)
1: 10
Set Output Flag High (Flag 0)
24: Set Active Storage Area (P80)
1: 01
Final Storage Area 1
2: 1
Array ID
; Store year, day in final storage - two reps for
;
two consecutive locations
25: Sample (P70)
1: 2
Reps
2: 30
Loc [ year
]
; Store hour/minute in final storage
26: Sample (P70)
1: 1
Reps
2: 35
Loc [ hr_min
]
; Store all of the remaining data
27: Sample (P70)
1: 1
Reps
2: 9
Loc [ BATT_WTHR ]
28: Sample (P70)
1: 1
Reps
2: 10
Loc [ BATT_SM
]
29: Sample (P70)
1: 1
Reps
2: 1
Loc [ T_C
]