Download WaveTest User`s Manual

Transcript
WaveTest User’s Manual
Probe Request
Generate a Probe Request frame.
FIELDS
Frame Control
Two-byte value for the Frame Control field. The format is byte0: byte1. See Frame
Control sub-command for details.
Duration
Two-byte value for the Duration field. The format is byte0: byte1. Bit 15 must be 0 for
this frame.
DA (Destination Address)
The DA field contains an IEEE MAC individual or group address that identifies the MAC
entity or entities intended as the final recipient of the MSDU (or fragment thereof)
contained in the frame body. The value is selected from one of the addresses defined
with the “Address” command.
SA (Source Address)
The SA field contains an IEEE MAC individual address that identifies the entity from
which the transfer of the MSDU (or fragment thereof) contained in the frame body
was initiated. The value is selected from one of the addresses defined with the
“Address” command.
©VeriWave, Inc. All rights reserved.
95