Download Lynx Plus Series Security Systems
Transcript
Lynx Plus Series Installation and Setup Guide Data Field Descriptions 25 X10 HOUSE CODE 26 CHIME BY ZONE Powerline Carrier Device (X10) House ID Powerline Carrier Devices require a House ID. This field identifies this House ID to the Control. The Powerline Carrier Devices are programmed in field ✻80. SELECTIONS 0=A 3=D 6=G 9=J # + 12 = M # + 15 = P 1=B 4=E 7=H # + 10 = K # + 13 = N 2=C 5=F 8=I # + 11 = L # + 14 = O Chime by Zone This option allows the installer to define the specific zones intended to chime when faulted while the system is in Chime mode. If enabled, these zones are defined in zone list 3 (see ✻81 Zone List Menu Mode). SELECTIONS 0 = no (chimes on fault of any entry/exit or perimeter zone when Chime mode is activated) 1 = yes (chimes on fault of those zones assigned to Zone List 3 when Chime mode on) 27 CLOCK DISPLAY Real Time Clock Display 29 DST MNTH STR/END STR END Daylight Savings Time Start/End Month 30 DST WEEK STR/END STR END Daylight Savings Time Start/End Month 31 SINGLE ALARM SND Single Alarm sounding Per Zone (per armed period) This field applies only to burglary zones (zone response types 1-5, 10). It applies only to the bell and does not affect keypad sounds. UL installations: must be 0 (no limit) Refer to the User’s Manual for setting the clock time and date. SELECTIONS 0 = do not display the time 1 = display the time Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12. SELECTIONS 0, 0 = no daylight saving time used 1-12 = start month and end month Enter the appropriate start and end weekend of the month. SELECTIONS 0 = disable 4 = fourth weekend 1 = first weekend of month 5 = last weekend 2 = second weekend 6 = next to last 3 = third weekend 7 = 3rd from last Lynx Plus SELECTIONS 0 = no limit on alarm sounding per zone 1 = limit alarm sounding to once per arming period for a given zone LynxSIA Plus SELECTIONS 0 = alarm sounding per zone will be the same as Swinger Shutdown set in field ✻92 1 = limit alarm sounding to once per arming period for a given zone 32 FIRE SND TIMEOUT Sounder Timeout This Control complies with NFPA requirements for temporal pulse sounding of fire and carbon monoxide (CO) notification appliances. Temporal pulse sounding for a fire alarm consists of the following: 3 pulses – pause – 3 pulses – pause – 3 pulses. . . Temporal pulse sounding for a CO alarm consists of the following: 4 pulses – pause – 4 pulses – pause – 4 pulses –pause. . . SELECTIONS 0 = yes, sounder timeout after time programmed in field ✻33 1 = no sounder timeout; continue sounding until manually turned off - 21 -