Lynx Plus Series Installation and Setup Guide
Data Field Descriptions
25
X10 HOUSE CODE
26
CHIME BY ZONE
Powerline Carrier Device (X10) House ID
Powerline Carrier Devices require a House ID. This field identifies this House ID to the
Control. The Powerline Carrier Devices are programmed in field ✻80.
SELECTIONS
0=A
3=D
6=G
9=J
# + 12 = M
# + 15 = P
1=B
4=E
7=H
# + 10 = K
# + 13 = N
2=C
5=F
8=I
# + 11 = L
# + 14 = O
Chime by Zone
This option allows the installer to define the specific zones intended to chime when
faulted while the system is in Chime mode. If enabled, these zones are defined in zone
list 3 (see ✻81 Zone List Menu Mode).
SELECTIONS
0 = no (chimes on fault of any entry/exit or perimeter zone when Chime mode is activated)
1 = yes (chimes on fault of those zones assigned to Zone List 3 when Chime mode on)
27
CLOCK DISPLAY
Real Time Clock Display
29
DST MNTH STR/END
STR END
Daylight Savings Time Start/End Month
30
DST WEEK STR/END
STR END
Daylight Savings Time Start/End Month
31
SINGLE ALARM SND
Single Alarm sounding Per Zone (per armed period)
This field applies only to burglary zones (zone response types 1-5, 10). It applies only to
the bell and does not affect keypad sounds.
UL installations: must be 0 (no limit)
Refer to the User’s Manual for setting the clock time and date.
SELECTIONS
0 = do not display the time
1 = display the time
Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12.
SELECTIONS
0, 0 = no daylight saving time used
1-12 = start month and end month
Enter the appropriate start and end weekend of the month.
SELECTIONS
0 = disable
4 = fourth weekend
1 = first weekend of month
5 = last weekend
2 = second weekend
6 = next to last
3 = third weekend
7 = 3rd from last
Lynx Plus SELECTIONS
0 = no limit on alarm sounding per zone
1 = limit alarm sounding to once per arming period for a given zone
LynxSIA Plus SELECTIONS
0 = alarm sounding per zone will be the same as Swinger Shutdown set in field ✻92
1 = limit alarm sounding to once per arming period for a given zone
32
FIRE SND TIMEOUT
Sounder Timeout
This Control complies with NFPA requirements for temporal pulse sounding of fire and
carbon monoxide (CO) notification appliances. Temporal pulse sounding for a fire alarm
consists of the following:
3 pulses – pause – 3 pulses – pause – 3 pulses. . .
Temporal pulse sounding for a CO alarm consists of the following:
4 pulses – pause – 4 pulses – pause – 4 pulses –pause. . .
SELECTIONS
0 = yes, sounder timeout after time programmed in field ✻33
1 = no sounder timeout; continue sounding until manually turned off
- 21 -