F-Link Supervised Transceiver System
The events can be downloaded onto a PC via the USB port using proprietary
Scope logging software (available as an option).
Specification
Input Voltage:
10-30V dc
Power Consumption:
zone)
<50mA operating, 300mA transmit (+25mA per active
Transmitter:
Power output:
500mW max
Frequency Range:
458.500 to 458.650 MHz
Channel Spacing:
12.5KHz
Adjacent Channel:
better than 10uW @ 2 KHz deviation
TX Baud Rate:
2400 Baud
Receiver:
Sensitivity
-100dBm
Radio Standards:
ETS EN 300 220
Notified Body No.
0891
EMC Standards:
ETS EN 301 489
Safety Standards
EN 60950
Ports:
4 dry contact Zone inputs (configurable)
4 relay Zone outputs (configurable)
1 relay output for Link Fail indication
USB port for programming/interface function
DIP switches for system configuration
Footprint (mm):
184 (L) x 138 (W) x 45 (D) max
excluding aerial