Platen Lowers
The main air valve is energized which allows it to
admit air to the DOWN port of the main pneumatic
cylinder. This causes the upper platen to begin descending as shown in Figure 4–3.
Trigger Switch Activated
The upper platen continues to descend until it activates the trigger switch. The trigger switch setting is indicated by the right flag on the front of
the press control panel. It is labeled with the word
TRIGGER at the bottom of the scale. The trigger
indicator light next to the scale markings illuminates when the trigger switch is activated. This is
illustrated in Figure 4–4. Setting the trigger position is covered in detail in Section 5 and 6.
Bottom Stop
Descending
Stroke Position
Indicator Flag
Platen and
Thermal Probes
Descending
Slide Table
Fully Retracted
Preheat Timer Activated
If the Preheat Timer option is not selected from
the menu, the Dwell Timer is activated and the
platen continues to descend.
If the Preheat Timer option is selected from the
menu, the main air valve is de–energized as soon
as the trigger switch is activated, This causes the
platen to stop descending and remain at its current position for the duration of the Preheat Timer.
At the end of the preheat cycle, the Dwell Timer
cycle begins. The main air valve is re–energized
and the platen continues to descend to its final
bottom position.
Figure 4–3
Main Air Valve Energized and Platen
Descending
Trigger Flag
Stroke Flag
Aligned
Aligned
Trigger Light
Illuminated
Mechanical Stop Contacted
The main air valve remains energized until the
Dwell Timer cycle expires. The platen descends
until it contacts the bottom mechanical stop. The
mechanical stop position is set by the large micrometer–type dial on the top of the press. Setting
the bottom stop is covered in detail in Section 5.
Thermal Probe
Just Touching
Insert
Post Cool Valve Energized
If the Post Cool Timer disable option is selected
from the menu (POST COOL OFF is lit), the platen
retraction cycle is started. If the Post Cool Timer
disable key is not overridden in the menu (POST
24
Figure 4–4
Trigger Switch Setting and Trigger Light
Dukane Manual Part No. 403–550–01