Download section 1
Transcript
Thermal Press User’s Manual Platen Lowers The main air valve is energized which allows it to admit air to the DOWN port of the main pneumatic cylinder. This causes the upper platen to begin descending as shown in Figure 4–3. Trigger Switch Activated The upper platen continues to descend until it activates the trigger switch. The trigger switch setting is indicated by the right flag on the front of the press control panel. It is labeled with the word TRIGGER at the bottom of the scale. The trigger indicator light next to the scale markings illuminates when the trigger switch is activated. This is illustrated in Figure 4–4. Setting the trigger position is covered in detail in Section 5 and 6. Bottom Stop Descending Stroke Position Indicator Flag Platen and Thermal Probes Descending Slide Table Fully Retracted Preheat Timer Activated If the Preheat Timer option is not selected from the menu, the Dwell Timer is activated and the platen continues to descend. If the Preheat Timer option is selected from the menu, the main air valve is de–energized as soon as the trigger switch is activated, This causes the platen to stop descending and remain at its current position for the duration of the Preheat Timer. At the end of the preheat cycle, the Dwell Timer cycle begins. The main air valve is re–energized and the platen continues to descend to its final bottom position. Figure 4–3 Main Air Valve Energized and Platen Descending Trigger Flag Stroke Flag Aligned Aligned Trigger Light Illuminated Mechanical Stop Contacted The main air valve remains energized until the Dwell Timer cycle expires. The platen descends until it contacts the bottom mechanical stop. The mechanical stop position is set by the large micrometer–type dial on the top of the press. Setting the bottom stop is covered in detail in Section 5. Thermal Probe Just Touching Insert Post Cool Valve Energized If the Post Cool Timer disable option is selected from the menu (POST COOL OFF is lit), the platen retraction cycle is started. If the Post Cool Timer disable key is not overridden in the menu (POST 24 Figure 4–4 Trigger Switch Setting and Trigger Light Dukane Manual Part No. 403–550–01