FlexDC Software User Manual Part II– FlexDC Software and Commands Reference 7.65 RS – Reset Controller Command Purpose: The “RS” command can be used to reset the controller software. “RS” causes the FlexDC micro-processor to enter a software reset state, and completely reinitializes the controller software. After Reset, all the controller parameters and script program resume their boot up values. The AUTOEX starts running like in power on condition. The “RS” command has the following attributes: Attributes: Syntax: XRS Type: Command. Axis related: No. Array: ---. Assignment: ---. Command Allows Parameter: No. Scope: All. Restrictions: All motors must be OFF, no program running. Save to Flash: ---. Default Value: ---. Range: ---. ‘ Resets the FlexDC. Nanomotion Ltd. 210