Download User Manual

Transcript
11.5.2 Digital Inputs [520]
Communication information
Modbus Instance no/DeviceNet no: 43231
Profibus slot/index
169/135
Fieldbus format
UInt
Modbus format
UInt
Submenu with all the settings for the digital inputs.
NOTE: Additional inputs will become available when the
I/O option boards are connected.
Digital Input 1 [521]
To select the function of the digital input.
AnIn4 Set-up [51B]
Same functions as AnIn1 Setup [512].
51B AnIn4 Setup
Stp A
4-20mA
Default:
4-20 mA
Dependent on
Setting of switch S4
Selection:
Same as in menu [512].
On the standard control board there are eight digital
inputs.
If the same function is programmed for more than one
input that function will be activated according to “OR”
logic if nothing else is stated.
521 DigIn 1
Stp A
RunL
Default:
Communication information
Off
RunL
0
Lim Switch+ 1
VSD ramps to stop and prevents rotation in
“R” direction (clockwise), when the signal
is low!
NOTE: The Lim Switch+ is active low.
NOTE: Activated according to “AND” logic.
Lim Switch - 2
VSD ramps to stop and prevents rotation in
“L” direction (counter clockwise) when the
signal is low!
NOTE: The Lim Switch- is active low.
NOTE: Activated according to “AND” logic.
Ext. Trip
3
Be aware that if there is nothing connected
to the input, the VSD will trip at “External
trip” immediately.
NOTE: The External Trip is active low.
NOTE: Activated according to “AND” logic.
4
Stop command according to the selected
Stop mode in menu [33B].
NOTE: The Stop command is active low.
NOTE: Activated according to “AND” logic.
Enable
5
Enable command. General start condition
to run the VSD. If made low during running
the output of the VSD is cut off immediately, causing the motor to coast to zero
speed.
NOTE: If none of the digital inputs are programmed to “Enable”, the internal enable
signal is active.
NOTE: Activated according to “AND” logic.
RunR
6
Run Right command. The output of the
VSD will be a clockwise rotary field.
RunL
7
Run Left command. The output of the VSD
will be a counter-clockwise rotary field.
Reset
9
Reset command. To reset a Trip condition
and to enable the Autoreset function.
Modbus Instance no/DeviceNet no: 43232
Profibus slot/index
169/136
Fieldbus format
UInt
Modbus format
UInt
AnIn4 Advanced [51C]
Same functions and submenus as under AnIn1
Advanced [513].
51C AnIn4 Advan
Stp A
Communication information
Stop
43233–43240
Modbus Instance no/DeviceNet no: 43544
43554
Profibus slot/index
169/137–144
170/193
170/203
The input is not active.
Preset Ctrl1 10 To select the Preset Reference.
Preset Ctrl2 11 To select the Preset Reference.
Functional Description
115