Download User Manual
Transcript
11.5.2 Digital Inputs [520] Communication information Modbus Instance no/DeviceNet no: 43231 Profibus slot/index 169/135 Fieldbus format UInt Modbus format UInt Submenu with all the settings for the digital inputs. NOTE: Additional inputs will become available when the I/O option boards are connected. Digital Input 1 [521] To select the function of the digital input. AnIn4 Set-up [51B] Same functions as AnIn1 Setup [512]. 51B AnIn4 Setup Stp A 4-20mA Default: 4-20 mA Dependent on Setting of switch S4 Selection: Same as in menu [512]. On the standard control board there are eight digital inputs. If the same function is programmed for more than one input that function will be activated according to “OR” logic if nothing else is stated. 521 DigIn 1 Stp A RunL Default: Communication information Off RunL 0 Lim Switch+ 1 VSD ramps to stop and prevents rotation in “R” direction (clockwise), when the signal is low! NOTE: The Lim Switch+ is active low. NOTE: Activated according to “AND” logic. Lim Switch - 2 VSD ramps to stop and prevents rotation in “L” direction (counter clockwise) when the signal is low! NOTE: The Lim Switch- is active low. NOTE: Activated according to “AND” logic. Ext. Trip 3 Be aware that if there is nothing connected to the input, the VSD will trip at “External trip” immediately. NOTE: The External Trip is active low. NOTE: Activated according to “AND” logic. 4 Stop command according to the selected Stop mode in menu [33B]. NOTE: The Stop command is active low. NOTE: Activated according to “AND” logic. Enable 5 Enable command. General start condition to run the VSD. If made low during running the output of the VSD is cut off immediately, causing the motor to coast to zero speed. NOTE: If none of the digital inputs are programmed to “Enable”, the internal enable signal is active. NOTE: Activated according to “AND” logic. RunR 6 Run Right command. The output of the VSD will be a clockwise rotary field. RunL 7 Run Left command. The output of the VSD will be a counter-clockwise rotary field. Reset 9 Reset command. To reset a Trip condition and to enable the Autoreset function. Modbus Instance no/DeviceNet no: 43232 Profibus slot/index 169/136 Fieldbus format UInt Modbus format UInt AnIn4 Advanced [51C] Same functions and submenus as under AnIn1 Advanced [513]. 51C AnIn4 Advan Stp A Communication information Stop 43233–43240 Modbus Instance no/DeviceNet no: 43544 43554 Profibus slot/index 169/137–144 170/193 170/203 The input is not active. Preset Ctrl1 10 To select the Preset Reference. Preset Ctrl2 11 To select the Preset Reference. Functional Description 115