13.1 Commands CM/CM? Selects scaling constants simultaneous setting command group or individual setting command group for command data which come after this command/ inquires about the current setting. Syntax CM m <terminator> “m” indicates command group used. m= 0: WT210/230 command/output format group (scaling constant simultaneous setting command group) 1: command/output format group by element (scaling constant individual setting command group) Query CM? <terminator> Example CM1 Description • Parameter error 12 will occur if “m” is set to an illegal value. • The output format of the WT210 is the same for m=0 or 1. DA/DA? Syntax Sets the function for display A/inquires about the current setting. DA m <terminator> “m” indicates one of the following functions. • in case of normal measurement m= 1: voltage (V) 2: current (A) 3: power (W) 4: reactive power (var) 5: apparent power (VA) 15: Elapsed integration time (TIME) • in case of harmonic measurement m= 1: Each relative harmonic content of 1st to 50 (or 30) th order of voltage (V) 2: Each relative harmonic content of 1st to 50 (or 30) th order of current (A) 3: Each relative harmonic content of 1st to 50 (or 30) th order of active power (W) 28: harmonic measurement order (order) Query DA? <terminator> Example DA1 Description Parameter error 12 will occur if “m” is set to an illegal value. 13-2 DB/DB? Sets the function for display B/inquires about the current setting. Syntax DB m <terminator> “m” indicates one of the following functions. • in case of normal measurement m= 1: voltage (V) 2: current (A) 3: power (W) 6: power factor (PF) 11: phase angle (deg) • in case of harmonic measurement m= 1: Measured value of each component of voltage (V) 2: Measured value of each component of current (A) 3: Measured value of each component of active power (W) 6: power factor (PF) 16: harmonic distortion factor of voltage (V THD) 17: harmonic distortion factor of current (A THD) 19: Relative harmonic content of each voltage component (V %) 20: Relative harmonic content of each current component (A %) 21: Relative harmonic content of each active power component (W %) 22: Phase angle between each voltage of the 2nd to 50 (or 30) th order and the fundamental (1st order) voltage. 23: Phase angle between each current of the 2nd to 50 (or 30) th order and the fundamental (1st order) current. Query DB? <terminator> Example DB1 Description Parameter error 12 will occur if “m” is set to an illegal value. DC/DC? Sets the function for display C/inquires about the current setting Syntax DC m <terminator> “m” indicates one of the following functions. • in case of normal measurement m= 1: voltage (V) 2: current (A) 3: power (W) IM 760401-01E