FD-348R User’s Reference Manual
Details [3]
Parameter
Range
Default
Description
(Fence / Buried)
Sensor on
Fence
Y or N
Y
Configures the APU for fence line or
buried (other) applications. A “Y” value
sets the system for fence line operation
Parameter
Range
Default
Description
Alarm Relay
Time
1 to 10 (sec)
1
Specifies the length of time, in seconds,
that the alarm will remain active once an
alarm condition is set
Parameter
Range
Default
Description
Enable User
Controlled
Relay Mode
Y or N
N
Allows the user to directly operate the
fault and alarm relay through FSN or
XML. This disables relay stimulus upon
an APU alarm/fault
Parameter
Range
Default
Description
Sensitivity
Factor
1 to 100
10
Scales the unprocessed signal from
the protected zone. Typically used to
increase signal amplitude in Spectraview
for improved signal visibility
Parameter
Range
Default
Description
1
Selects the communication mode that the
APU will use to provide alarm and status
information. Choose between Relay
Only(0), FSN(1), or XML(2)
Communication
Mode
0 to 2
When XML mode is enabled (see Chapter 7, page 7-13) the following additional
menu option becomeS available within the Details menu.
Parameter
Range
Default
Description
XML Report
Interval
1 to 600 (.1sec)
10
Adjusts the maximum frequency with
which XML reports are output
5-14