Download 4 - D3E Electronique
Transcript
Measurement Data That Can Be Used for External Outputs and Calculations The following values can be used as measurement data and output to external devices via the Ethernet or used in calculations. Expression text string Data name Description Data range JG Judgement This is the judgement result. −2: No judgement (not measured), 0: Judgement is OK, −1: Judgement is NG, −13: Teaching not performed error, −14: Figure not registered error, −15: Out of range error AR R average This is the average value of the R (red) component. 0 to 255 AG G average This is the average value of the G (green) component. 0 to 255 AB B average This is the average value of the B (blue) component. 0 to 255 AD Color difference This is the difference between the average color and reference color within the region. 0 to 442 DV Color deviation This is the color deviation within the region. 0 to 221 4-9 Calculations and Judgements Using Inspection Item Data: p. 75 Measurement Data That Can Be Logged (Color Data) The following values can be logged as measurement data. Measured item Range of value Description Color Dif. 0 to 442 This is the difference between the color that was registered as the reference and the measured color. The average color within the measurement area is used in both cases. 7-4 Logging Measurement Data and Image Data: p. 110 Increasing Processing Speed for Color Data Make the measurement region smaller to reduce the processing time. Changing the measurement region: p. 57 74 Inspecting with Color Data Inspection Item FQ User’s Manual D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHILL 10302 SAINTE SAVINE Tél: 03 25 71 31 50 Fax: 03 25 74 38 82 Email: [email protected] WWW.d3e.fr