177 Index 96.07 96.08 96.09 96.10 96.11 96.12 Name/Selection Description FbEq CONTROL DEV See parameter 15.01. 12 ACTUAL 1 See parameter 15.01. 13 ACTUAL 2 See parameter 15.01. 14 COM.REF5 See parameter 15.06. 15 PARAM 96.12 Source selected by parameter 96.12. 16 INVERT EXT AO2 Activates the inversion of analogue output AO2 of the analogue I/O extension module. The analogue signal is at its minimum level when the drive signal indicated is at its maximum and vice versa. NO Inactive 0 YES Active 65535 MINIMUM EXT AO2 Defines the minimum value for analogue output AO2 of the analogue I/O extension module. See parameter 96.03. 0 mA 0 mA 1 4 mA 4 mA 2 10 mA 10 mA 3 12 mA 12 mA 4 FILTER EXT AO2 Defines the filtering time constant for analogue output AO2 of the analogue I/O extension module. See parameter 15.04. 0.00 … 10.00 s Filtering time constant SCALE EXT AO2 Defines the scaling factor for analogue output AO2 of the analogue I/O extension module. See parameter 15.05. 10 … 1000% Scaling factor 100 … 10000 EXT AO1 PTR Defines the source or constant for value PAR 96.11 of parameter 96.01. 1000 = 1 mA -255.255.31 … +255.255.31 / C.32768 … C.32767 Parameter index or a constant value. See parameter 10.04 for information on the difference. - EXT AO2 PTR Defines the source or constant for value PAR 96.12 of parameter 96.06. 1000 = 1 mA -255.255.31 … +255.255.31 / C.32768 … C.32767 Parameter index or a constant value. See parameter 10.04 for information on the difference. - 98 OPTION MODULES 0 … 1000 Activation of the option modules. The parameter settings will remain the same even though the application macro is changed (parameter 99.02). 98.01 ENCODER MODULE Activates the communication to the optional pulse encoder module. See also parameter group 50 ENCODER MODULE. NTAC Communication active. Module type: NTAC module. Connection interface: Fibre optic DDCS link. 0 Note: Module node number must be set to 16. For directions, see the NTAC-0x/NDIO-0x/NAIO-0x Module Installation and Start-up Guide [3AFY58919730 (English)]. NO Inactive 1 RTAC-SLOT1 Communication active. Module type: RTAC. Connection interface: Option slot 1 of the drive. 2 Actual signals and parameters