Detailed settings (if necessary)
When measurement is not stable, adjust the detailed conditions.
X MENU mode - [Setup] - [Item] - [Detail]
Setup Item
Setting value
Description
Measure axis angle
OFF (default value)
Sets whether or not to measure the axis angle. When [ON] is selected, the processing time increases proportionately to the time it takes to measure the axis angle.
ON
Fill profile
OFF (default value)
ON
To measure the outer periphery of the measurement target, set this item to [ON].
When this item is set to [ON], measurement is performed with all of the
area between the start point (colors outside of measurement target →
measurement target color) and the end point (measurement target
color → colors outside of measurement target) inside the measurement
region judged to the measurement target color.
End point
SETTING THE MEASUREMENT CONDITIONS
Start point
3
Measurement
region
Fill profile: ON
When the measurement target color is overlaps the measurement region
Input image (Fill profile: OFF)
Fill profile: ON
Pixels that are measurement target color are not recognized as the start point
as pixels that are colors outside of measurement target are next scanned.
When measuring the measurement target with unevenness
The measurement result changes according to the direction in
which the measurement target is fed.
Input image (Fill profile: OFF)
Calibration
Coordinates mode
Fill profile: ON
OFF (default value)
Measurement results are output using the camera's coordinate values.
ON
Measurement results are output using the coordinate value converted by the
calibration function.
Normal
(default value)
The position information of the input image coordinate system itself
is output.
Pos. correction
When position shift correction is set, the position information is output using the coordinate system corrected to the original state
when the coordinate system was registered.
Coordinates mode p.63
ZFX-C User’s Manual
Setting Measurement Items
57