Download Instruction Manual
Transcript
If the pump is set at 60% speed and 70% stroke length, the approximate pump output is: 24.0 x 0.60 x 0.70 = 10.08 GPD (gallons per day) Divide by 24 (hours in one day) to calculate GPH (gallons per hour). If pump is not equipped with speed adjustment, calculate by Max Pump Output x % Stroke only. 5.0 CALIBRA TION CALIBRATION Once installation is complete and the approximate output has been determined, the pump may be calibrated to adjust speed (if equipped) and stroke for your actual desired output. 1. Be sure the pump is primed, and discharge tubing and Injection Check Valve are installed as they would be in normal service (i.e., including factors such as injection pressure, fluid viscosity, and suction lift). 3. Place the foot valve in a graduated container with a volume of 1000 ml or more. 4. Start the pump and run until all the air is exhausted from the suction line and head. 5. Disconnect power to the pump. Refill graduated container to a level starting point. 17