Protocol Proto-3, 4
Not used.
Protocol C12
Sets the response code for connect for AT command, Marked means always response with CONNECT 1200.
Protocol Proto-6, 7, 8
Not used.
Connect Timeout
Sets the time for disconnect on idle line. If the communication is hold longer then the selected time, the line is disconnected.
Activity timeout
Sets the time for restart on idle activity. If the communication is hold longer than the selected time, the Net Controller is reset.
Serial-1 Receive Timeout
Sets the time for received time gap for serial port-1. The received characters is buffered until the time gap occurred. The message is terminated and
send via network.
Serial-2 Receive Timeout
Sets the time for received time gap for serial port-2. Se parameter Serial-1 Receive Timeout.
Identity
Identity by 8 characters. Used to give every Net Controllers it’s own Id. Used by the WEB browser to login to get access to configuration.
Password
Password by 8 characters. Used to give every Net Controllers a password. Used by the WEB browser to login to get access to configuration.
Encryption key
Encryption key by 8 characters. 64 Bits encryption for data messages.
Security Service
Enable the possibility to set the Option Test and Ethernet address. Only for factory.
Security Reset
Enable Reset of Net Controller. The Net Controller is reset and the factory setup of parameters is done.
Switch High/Low Impedance
RS485, switch between high/low impedance for receive. For point to point connection should be set low. For multipoint connection, the master and
terminating slaves should be set to low and all th other to high.