Download EmbedSense® Quick Start Guide

Transcript
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
The next step is to verify communication between the Reader Assembly and the
Node.
Ensure that only one Node is lying on top of or underneath the Reader Assembly.
By default, an address of 16384 should be entered in the Node Address scroll box.
If not, enter that specific address.
Click the Ping (Node) button.
Look for a successful ping message in the Console frame. See Figure 2.
Note: Each Node has a unique address ranging between 1 and 65535. Look on the
Node label for the unique address applied at the factory. The exception is the
16384 ‘broadcast’ address; each Node will respond to its unique address and all
Nodes will respond to the broadcast address.
To determine the Node’s unique address, enter 50 in the EEPROM Location
scroll box; this is the location in the Node’s EEPROM map where its unique
address is maintained.
Click the Read button.
Look for a successful read message in the Console frame indicating what the
value in EEPROM 50 is and therefore the unique Node address. See Figure 3.
Note: When working with multiple nodes, the unique addresses should always be
used to insure data integrity.
Enter the address found in EEPROM 50 in the Node Address scroll box.
Click the Ping (Node) button.
Look for a successful ping message in the Console frame. See Figure 4.
An EmbedSense™ Node has 2 sensing channels.
Channel 1 is the internal temperature sensor and channel 2 is the differential input
circuit, designed to accommodate Wheatstone bridge sensors with 1000 ohm
resistors or greater.
The Node is supplied with a full Wheatstone bridge of 1000 ohm resistors for
evaluation.
Figure 5 shows the Calibration Coefficients required to scale the raw ‘bits’ from
the system into engineering units.
Enter 0.00457770 for the channel 1 (temperature sensor) Gain1.
Enter -50.0 for the channel 1 (temperature sensor) Offset 1.
Enter 0.001 for the channel 2 (differential input) Gain 2.
Enter 0.0 for the channel 2 (differential input) Offset 2.
Insure that the Node is in close proximity to the Interrogation Antenna
Click the Stream button.
Channels 1 (green trace) and 2 (red trace) will begin sampling and displaying on
the graph. See Figure 6.
The X-axis represents number of samples collected and the Y-axis represents
engineering units.
Note: Remember that two different engineering units are being displayed on the
same graph. The Y-axis auto-scales accordingly. In this case we are looking at
degrees C and millivolts.
2