Download flight operations manual cirrus perspective
Transcript
Flight Operations Manual Abnormal and Emergency Procedures Cirrus Perspective Section 4 Electrical Fire (Cabin Fire In Flight) An electrical fire or cabin fire in flight is an emergency situation requiring immediate pilot action. The pilot must turn off power sources and electrical equipment to eliminate an electrical fire. In VFR conditions, it is recommended to turn off both batteries and alternators. Reference the magnetic compass, backup airspeed indicator, backup altimeter, and outside visual reference for aircraft control. In IMC conditions, or conditions that require flight by reference to instruments, turn off all switches except BATT 2 to preserve power to the primary flight display and backup attitude indicator. There is a high probability that the source of fire will be eliminated. Turn off BATT 2 if the fire continues to burn. Activate CAPS if controlled flight can not be maintained. Procedure 1. Oxygen System (if applicable) .................................................OFF Turn off the oxygen system, if applicable, to reduce the chance of a severe fire in the cabin. 2. Bat-Alt Master Switches ........................................ OFF, AS REQ’D In VFR, turn off all battery and alternator switches. When flight by reference to instruments is required, leave BATT 2 ON. 3. Fire Extinguisher ............................................................ ACTIVATE • Note • If airflow is not sufficient to clear smoke or fumes from cabin: 4. Cabin Doors ...................................................... PARTIALLY OPEN 5. Avionics Power Switch .............................................................OFF 6. All other switches .....................................................................OFF 7. Land as soon as possible. It is not possible to maintain aircraft control in IMC without electrical power to the PFD and/or backup attitude indicator. Activate CAPS if aircraft control can not be maintained. 8. Air Conditioner (if installed) ......................................................OFF 9. Airflow Selector ........................................................................OFF 10. Bat-Alt Master Switches ............................................................ ON 4-28 P/N 23020-002 Feb 2011