Download Phase 5 DMC

Transcript
BAD COIN LOCKOUT STATUS (bCLO)
In this program status (“bCLO”), each coin entry is monitored. Should someone tamper with the coin acceptor
or attempt to insert a foreign object, the Phase 5 Dual Microprocessor Controller (DMC) computer will LOCK
UP and not accept any entries until the reset time has elapsed (approximately 15-seconds). Once the reset time
has expired, the Phase 5 DMC (computer) will automatically reset itself for the next coin entry.
BAD COIN RESET (bCrS)
When set in this program (“bCrS”), the Phase 5 Dual Microprocessor Controller (DMC) computer counts in
milliseconds the amount of time required for a coin entry signal. If someone should tamper with the coin acceptor
or attempt to insert a foreign object, the Phase 5 DMC (computer) will not accept the entry and will automatically
reset itself for the next entry.
ACCUMULATIVE TIME (AtIn)
(SINGLE COIN)
In this program mode (“AtIn”), each coin inserted has a specific value in time which is determined by the “Time
For Amount To Start” (“tFAS”) program (PL11).
Example No. 1: If the dryer is equipped with a 25¢ coin acceptor and the desired time is 30 minutes, each
additional coin inserted would yield 30 minutes.
Settings: PL09 (LCdE) .......................25
PL11 (tFAS) .........................30
PL12 (AtSt) ..........................25
Example No. 2: If the dryer is equipped with a 25¢ coin acceptor and the “Amount To Start” (“AtSt”) is 50¢
for 30 minutes, the insertion of each additional coin would yield 15 minutes. In this application
the “Time For Amount To Start” (“tFAS”) is determined by a Phase 5 Dual Microprocessor
Controller (DMC) computer calculation. There is no calculation required by the owner.
Formula: (LCdE/AtSt)(tFAS) = Vended Time for “ LCdE”
(25¢/50¢)(30) = 15 Minutes
Settings: PL09 (LCdE) .......................25
PL11 (tFAS) .........................30
PL12 (AtSt) ..........................50
16