Download VINGTOR talk-back & intercom systems

Transcript
amplIfIeRs
300501023 5
Vpa-120 pOWeR amplIfIeR, 120W
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
power amplifier in a 19” rack cabinet
100 V and 8 ohm output
Dual inputs with priority switching
temperature controlled, forced back-to-front ventilation
115/230 Vac mains and 24 VDc battery backup
power consumption at 0db 24V Dc 7,5 a
power consumption at 0db 230V ac 1.7 a
pilot tone line monitoring
24 VDc / 800 ma power output for external equipment
chime signal with on/off switch
size (WxHxD): 482 x 133 x 420 mm Weight: 18.2 kg
additional information:
tested according to iec 60945, iacs e10, iec 60533
300501023 7
Vpa-240 pOWeR amplIfIeR, 240W
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
power amplifier in a 19” rack cabinet
100 V and 8 ohm output
Dual inputs with priority switching
temperature controlled, forced back-to-front ventilation
115/230 Vac mains and 24 VDc battery backup
power consumption at 0db 24V Dc 15,4 a
power consumption at 0db 230V ac 3.1 a
pilot tone line monitoring
24 VDc / 800 ma power output for external equipment
chime signal with on/off switch
size (WxHxD): 482 x 133 x 420 mm Weight: 21.2 kg
additional information:
tested according to iec 60945, iacs e10, iec 60533
3006206019
300501023 9
Rs-3c Rack 3HU, TeRmINals
f/230Vac/24VDc IN/OUT
Vpa-400 pOWeR amplIfIeR, 400W
ƒ 19”, 3U cabinet prepared for amplifier
ƒ prepared with necessary terminals for
signal in/out and power supply
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
power amplifier in a 19” rack cabinet
100 V and 8 ohm output
Dual inputs with priority switching
temperature controlled, forced back-to-front ventilation
115/230 Vac mains and 24 VDc battery backup
power consumption at 0db 24V Dc 28,0 a
power consumption at 0db 230V ac 5.4 a
pilot tone line monitoring
24 VDc / 800 ma power output for external equipment
chime signal with on/off switch
size (WxHxD): 520 x 450 x 180mm Weight: 6.0 kg
size (WxHxD): 482 x 133 x 420 mm Weight: 24.2 kg
additional information:
additional information:
tested according to iec 60945, iacs e10, iec 60533
maNUals & spaRes
a1 0 0K11162
a 100K 1086 4
3005020024
etb-5-10-100 installation & operation Manual
ctb-100 installation & user Manual
standard set of spares for etb-5/10/100
a1 0 0K11163
a 100K 1087 1
3005020024
etb-5-10-100 user guide
voc-200 installation & user Manual
standard set of spares For ctb-10/20 and
cu-10/20/100/200
a1 0 0K10865
ctb installation & user Manual
18