Section 7-1 PLC Setup Polling Unit: Number of Link Words Address in Programming Console Word 166 Bit(s) 4 to 7 Settings Function 1 to A This setting specifies the number of words per node in the Serial PLC Link Area to be Default: 0 (See used for Serial PLC Links. note.) Note: If the default is set, the number of words will automatically be 10 (A hex). Related flags and words A61902 (RS-232C Port Settings Changing Flag) When setting is read by CPU Unit At the next cycle. Polling Unit: Maximum Unit Number in Serial PLC Link Address in Programming Console Word 166 Bit(s) 0 to 3 Settings 0 to 7 Default: 0 Function Related flags and words This setting specifies the highest Polled Unit unit number that can be connected in Serial PLC Links. Note: If a PT is to be connected, it must be included when counting Units. . A61902 (RS-232C Port Settings Changing Flag) When setting is read by CPU Unit At the next cycle. Polled Unit: Serial Communications Mode Address in Programming Console Word 160 Bit(s) 8 to 11 Settings 7: Serial PLC Link Polled Unit Default: 0 Function Related flags and words This setting specifies the serial communications mode that the RS-232C port is to be used with. It also designates the local node as a a Serial PLC Link Polled Unit. A61902 (RS-232C Port Settings Changing Flag) Function Related flags and words This setting specifies the Serial PLC Link baud rate. Note: The setting must be the same for all of the Polled Units and the Polling Unit using Serial PLC Link. A61902 (RS-232C Port Settings Changing Flag) When setting is read by CPU Unit At the next cycle. Polled Unit: Port Baud Rate Address in Programming Console Word Bit(s) 161 0 to 7 Settings 00: 9,600 bps 0A: 115,200 bps Default: 00 When setting is read by CPU Unit At the next cycle. Polled Unit: Serial PLC Link Polled Unit Unit Number Address in Programming Console Word Bit(s) 167 0 to 3 Settings 0 to 7 Default: 00 Function Related flags and words This setting specifies the Polled Unit unit A61902 number for the local node on the Serial PLC (RS-232C Link. Port Settings Changing Flag) When setting is read by CPU Unit At the next cycle. 207
Related documents
Version 1.9
SYSMAC CJ Series CJ1G CPU## Programmable Controllers
CS1PC-PCI01-DRM CS1PC-PCI01H-DRM CS1PC
OPERATION MANUAL
PROGRAMMING MANUAL Programmable Controllers
CS/CJ Series Programmable Controllers
CX-Programmer Operation Manual
Série CJ E/S intégrées UCs CJ1M-CPU21/22/23 Manuel d`utilisation
User Manual - FTP Directory Listing
Omron CS1D PCS User Manual
User Manual D637-R/D639-R Series Servo Valves
Automates programmables MANUEL D`UTILISATION