3 - TECHNICAL DATA
TABLE 1
Model
X
Ø 80
Y
Ø 100
Z
Ø 120
Gas oven
GN 1/1
Gas oven
GN 2/1
Gas oven
MAXI
Category
II2H3+
Construction type
A
Air necessary for combustion
m3/h
9
15
17
7.5
16
26.5
Nominal thermal power
kW
4.3
6.4
8.3
3.6
7.8
12.0
Minimum thermal power
kW
1.2
1.8
2.9
0.75
-
-
Overall thermal power (gas)
Hour consumption
G20
m3/h
G25
m3/h
G30/G31
kg/h
K2F • OP2F
11.2 kW
1,19
-
0,88
K4F • K4FFE • B4F • OP4F
28.3 kW
2,99
-
2,21
K6F • K6FFE • B6F • OP6F
39.5 kW
4,16
-
3,08
K8F • K8FFE • B8F • OP8F
54.7 kW
5,79
-
4,28
K4FFG
36.1 kW
3,81
-
2,82
K6FFG
47.3 kW
4,98
-
3,69
K8FFG
70.3 kW
7,44
-
5,50
K4FS • K4FSFE
34.2 kW
3,61
-
2,67
K4FSFG
42.0 kW
4,44
-
3,28
K4FSFCG
37.8 kW
3,99
-
2,95
K4FSFCE
34.2 kW
3,61
-
2,67
K6FFGA
51.5 kW
5,45
-
4,03
Connection pressure
Methane gas 2H
G20
20 mbar
Liquid gas 3+
G30/G31
28/37 mbar
Paramètres raccordement du gaz
Methane gas 2H
(HuB = 9.45 kWh/m3) in m3/h
0.455
0.677
0.878
0.421
0.825
1.375
Liquid gas 3+
(HuB = 12.87 kWh/kg) in kg/h
0.334
0.497
0.645
0.281
0.606
1.010
Nozzles Ø 1/100 mm
G20
Main burner
G30/31
Nominal thermal power
150
180
200
155
215
270
Minimal thermal capacity
Adjustable
Adjustable
Adjustable
Adjustable
-
-
Nominal thermal power
100
120
140
100
140
170
Minimal thermal capacity
45
55
80
48
-
-
G20
35
35
35
-
35
35
G30/G31
20
20
20
-
20
20
Methane gas G20
5
4
10
Open
12
3
Liquid gas G30/G31
8
9
12
Open
10
Open
No. of nozzles, pilot burner
Primary air distance “A”
Electrical data
Electric oven power:
Voltage:
No. of cables per section:
GN 2/1 - 5.9 kW
V 400 3N 50 Hz / 230 3 50 Hz
5 x 2.5 mm2 / 4 x 2.5 mm2
GN 1/1 - 2.5 kW
230 50 Hz
3 x 1.5 mm2
011_03 - GAS KITCHENS
07/2009
8 · 22