Download W15PTOS/D - GenPro Power Systems, Inc.
Transcript
All PTO units have a full control panel with features like large frequency meter, mainline circuit breaker, convenience and full load 4-wire receptacles. The full load matching plug is also included for customers load connection cord set. Traditional Winco power, convenience and reliability are standard features of this new series of compact PTO generators. TRACTOR PTO HP INPUT SHAFT GEAR LUBE FEATURES BY MODEL MOTOR ** WATTS STARTING MAX / RATED AMPS @ 120/240V W15PTOS/C 36/30 1-3/8 6SPL 16 OZ 8 HP 18,000 / 15,000 83 / 60 **MOTOR STARTING – CODE ‘G’ CAPACITOR START – *FEATURES – LISTED BELOW BY REFERENCE NUMBER WITH EXPLANATION – FEATURES* 1, 2, 3, 4, 5, 6 1 – Brushless, low harmonic design with skewed rotor and damper windings for minimal load noise 2 – Capacitor Excitation 3 – Dual voltage - 120/240 volt output 4 – 4 wire Load connection plug for convenient full load 120/240 volt output cordset 5 – 15Amp duplex convenience receptacle 6 – Large face Frequency meter for setting proper speed SAFETY INFORMATION INTRODUCTION The words generator and alternator are used interchangeably but have the same meaning. This manual covers standby generators driven by the power take-off of a compact tractor. This generator use a external voltage regulator excitation system. All generators are carefully inspected, tested and packaged for shipment at the factory. The generator should be unpacked as early as possible upon receipt and inspected for damage which may have occurred during shipment. Any damage noted should be promptly reported to the carrier in order that a claim can be filed to recover the cost of the damage. If at all possible, this damage should be noted on the freight bill at the time of delivery. If the damage appears to be of a major nature, the generator should not be operated until the fault has been corrected. Tractor driven generators are designed to deliver voltage and current similar to that of the normal power line. Equipment that can be operated on normal power can also be operated by the generator, provided that the capacity of the generator is not exceeded. It should be remembered that the power line, for all practical purposes, is backed by an unlimited generator. When not in use the generator should be stored in a clean dry location. All types of mechanical equipment suffer from long periods of storage without use. The generator should be used at frequent intervals to prevent deterioration and detect possible fault before an emergency condition develops. This generator set has been designed and manufactured to allow safe, reliable performance. Poor maintenance, improper or careless use can result in potential deadly hazards; from electrical shock, exhaust gas asphyxiation, or fire. Please read all safety instructions carefully before installation or use. Keep these instructions handy for future reference. Take special note and follow all warnings on the unit labels and in the manuals. ANSI SAFETY DEFINITIONS DANGER: DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations. WARNING: WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. NOTE: CAUTION is also used on the unit labels and in this manual to indicate a situation that could result in serious damage or destruction of the equipment and possible personal injury. Page 1 60706-179-8100