Probe Library-Offset Tab This frame shows the offset from magnification Med High master mag High. These offset are also known as parcentricity and parfocality. If you click on teach the system will walk you through the calibration. You should start this procedure at Med High. Notice reference is not checked. Only the master probe in the group is checked. The same calibration needs to be done for each of the magnifications, except High, which is the Master Probe in group. to the (HIGH) other this Transport Movement Calibration QC5000 Grid Calibration Procedure OVERVIEW 1. Start QC5000 (Ensure that all other optical and mechanical adjustments and calibrations have been done first.) 2. Turn off the NLEC. Click on (Tools \ Options \ Nlec) and uncheck the (Nlec Enabled) check box. 3. Open the calibration program. This should be in (C:\Optek\Calibration\ Calibration.5pa). 4. Place toggle breakpoint after skew and zero steps. Right click on the first grid measurement step. Click on (Editing steps \ Toggle break point). 5. Open NLEC controller. Click on (Tools / Options / NLEC, Click Calibrate) 6. Right click in the background between grid stations. 7. For certified grids only. Click on (File \ Import) and browse to the ACF file that matches the Grid s/n. For other grid masters, click on (File \ New) and enter all relevant information. 8. Verify columns / rows correct for grid stations to be used. 9. Right click in the background between grid stations. 10. Click on (Calibrate \ Start). 11. Run the program. Click on the (New Run) button. The machine will measure the skew and zero points and then stop at the break point that was set in step #4. 12. In the NLEC controller window, right click on the lower left grid station, and then left click on (Zero). This tells the NLEC controller where the zero and skew line exist. 13. Click on the button (Run from current step), this runs the program from the first grid measurement step. Most tolerances will show up as failed (RED) and should be ignored at this point. 14. When the program is finished running. In the NLEC controller window, right click in gray area. Then click on (File\ Save) give it a sensible name (NLEC Reference) and save it in: C:\ QC5000 as – (“date of cal “.txt). This save is just for a calibration record. 15. In the NLEC controller window, right click in gray area again. Then click on (File \ export) and accept the default name and location for the export. This exports all of the adjusted NLEC grid data from the controller to a text file that will be read by the QC5000. 16. Turn on the NLEC. Click on (Tools / Options / NLEC) and put a check mark in the box (Enable). 17. Shut down QC5000 and restart. Verify the Calibration Choose the calibration program. (File / Open / “calibration check .5pa”) Add Fields to the features template. Check the calibration, note the x difference from nominal and y difference from nominal fields to the feature window. Measure the grid with the same program as in calibration with no changes in edge teach or lighting. The tolerances should now be green with NLEC enabled. Export the data. Save as “CAL Data and date of calibration” .csv file Recalibrate if necessary. 38