Download Publication # 890034-05-00
Transcript
100 10 Off 1.0 Off 0.1 Off 0.1 15 10 Off Off 3.0 Off Off 0.1 0.2 72 23 0.1 Off Off 10.0 Off Off Off Off Off On Off Off Off 10 10 60 30.0 90 15 Off Stop Off Off Off Off Off Off Off 0.1 Fault FS Off Off Off Off Off Off 50 0.1 100 0 Off 100 0 %FLA Seconds %FLA Seconds %FLA Seconds %FLA Seconds % Seconds %FLA Amps Seconds % % Seconds Seconds Hz Hz Seconds Seconds Minutes Minutes Seconds Seconds Seconds % Minutes % % % Seconds % Seconds % % % % Description Default Units Inline Configuration Bypass / 2M Confirm Keypad Stop Disable Power On Start Selection RTD Module #1 Address RTD Module #2 Address RTD1 Group RTD2 Group RTD3 Group RTD4 Group RTD5 Group RTD6 Group RTD7 Group RTD8 Group RTD9 Group RTD10 Group RTD11 Group RTD12 Group RTD13 Group RTD14 Group RTD15 Group RTD16 Group Stator Alarm Level Bearing Alarm Level Other Alarm Level Stator Trip Level Bearing Trip Level Other Trip Level RTD Voting RTD Motor OL Biasing RTD Bias Minimum Level RTD Bias Mid Point Level RTD Maximum Level Meter 1 Meter 2 CT Ratio Phase Order Rated Voltage Motor Rated Power Factor Starter Type Heater Level Energy Saver PORT Fault Time PORT Bypass Hold Time PORT Recovery Method Tachmeter Full Speed Voltage Tachometer Loss Time Tachometer Loss Action Communication Address Communication Baud Rate Communication Timeout Communication Byte Framing Software 1 MX3 Card 1 Software 2 MX3 Card 2 Miscellaneous Commands 3.0 2.0 Enabled Disabled Seconds Seconds FUN 23 Time and Date Format FUN 24 FUN 25 FUN 26 FL1-9 E01-99 Time Date Passcode Fault Log Event Log Publication # 890034-05-00 Off Off o 200 Off Off 40 130 155 Ave Current Ave Volts 288:1 Insensitive 480 -0.92 Normal Off Off Off Off Fast Recover 5.00 1.5 Fault 1 19200 Off Even, 1 Stop 810023-02-01 810024-01-01 None mm/dd/yy 12hr Present Time Present Date Off C Control Quickstart Reference Guide For The LCD Display o C C o C o For more information consult the RediStart MX User Manual (RB3,RC3 & RX3E Models) 3 RMS Volt %FLA Seconds Seconds Volts Seconds bps Seconds *NOTE: See MX3 User Manual for the complete parameter descriptions. *NOTE: Parameters in bold print are the most commonly used in initial start up. December 2006 Motor Starter Card Set: BIPC-400100-01-03 MX3 Card 1: 810023-02-01 MX3 Card 2: 810024-01-01 USA Headquarters: USA West: Canada: Website: Email: (412) 487-8235 (480) 905-0601 (519) 291-5112 http://www.benshaw.com [email protected] NS 3 TH E BE Slow Speed Current Level Slow Speed Time Limit Slow Speed Kick Level Slow Speed Kick Time Over Current Trip Level Over Current Trip Delay Time Under Current Trip Level Under Current Trip Delay Time Current Imbalance Trip Level Current Imbalance Trip Delay Time Residual Ground Fault Trip Level Zero Sequence Ground Fault Trip Level Ground Fault Trip Time Over Voltage Trip Level Under Voltage Trip Level Over/Under Voltage Trip Time Phase Loss Time Over Frequency Trip Under Frequency Trip Frequency Trip Time PF Lead Trip Time PF Lag Trip Level PF Trip Time Backspin Timer Time Between Starts Starts per Hour Auto Fault Reset Time Auto Fault Reset Count Limit Controlled Fault Stop Enable Speed Switch Trip Time Motor PTC Trip Time Independent Starting/Running Overload Motor Starting Overload Class Motor Running Overload Class Motor Overload Hot/Cold Ratio Motor Overload Cooling Time Motor OL Alarm Level Motor OL Lockout Level Motor OL Auto Lockout Level DI 1 Configuration DI 2 Configuration DI 3 Configuration DI 4 Configuration DI 5 Configuration DI 6 Configuration DI 7 Configuration DI 8 Configuration Digital Fault Input Trip Time R1 Configuration R2 Configuration R3 Configuration R4 Configuration R5 Configuration R6 Configuration Analog Input Trip Type Analog Input Trip Level Analog Input Trip Delay Time Analog Input Span Analog Input Offset Analog Output Function Analog Output Span Analog Output Offset Parameter LCD I/O 24 I/O 25 I/O 26 I/O 27 RTD 01 RTD 02 RTD 03 RTD 04 RTD 05 RTD 06 RTD 07 RTD 08 RTD 09 RTD 10 RTD 11 RTD 12 RTD 13 RTD 14 RTD 15 RTD 16 RTD 17 RTD 18 RTD 19 RTD 20 RTD 21 RTD 22 RTD 23 RTD 24 RTD 25 RTD 26 RTD 27 RTD 28 RTD 29 FUN 01 FUN 02 FUN 03 FUN 04 FUN 05 FUN 06 FUN 07 FUN 08 FUN 09 FUN 10 FUN 11 FUN 12 FUN 13 FUN 14 FUN 15 FUN 16 FUN 17 FUN 18 FUN 19 FUN 20 FUN 21 FUN 22 H AW Year Warranty E Units S Default O MI Description PR Parameter LCD CFN 24 CFN 25 CFN 26 CFN 27 PFN 01 PFN 02 PFN 03 PFN 04 PFN 05 PFN 06 PFN 07 PFN 08 PFN 09 PFN 10 PFN 11 PFN 12 PFN 13 PFN 14 PFN 15 PFN 16 PFN 17 PFN 18 PFN 19 PFN 20 PFN 21 PFN 22 PFN 23 PFN 24 PFN 25 PFN 26 PFN 27 PFN 28 PFN 29 PFN 30 PFN 31 PFN 32 PFN 33 PFN 34 PFN 35 I/O 01 I/O 02 I/O 03 I/O 04 I/O 05 I/O 06 I/O 07 I/O 08 I/O 09 I/O 10 I/O 11 I/O 12 I/O 13 I/O 14 I/O 15 I/O 16 I/O 17 I/O 18 I/O 19 I/O 20 I/O 21 I/O 22 I/O 23 Operate Screen (see user manual for additional descriptions) Operate Screen Display No Line Stopped Ready Overload Alarm Overload Fault Overload Lockout Ctl Pwr Lockout Time Btw Starts Starts per Hour Mtr PTC Lockout RTD Lockout Fault Heater Kick Accel Kick 2 Accel 2 Run UTS Control Decel Wye Slow Spd Fwd Slow Spd Rev Braking PORT The operate screen is the main screen. The Operate screen is used to indicate the status of the starter, if it is running, what state it is in, and display the values of Meter 1 (FUN01) and Meter 2 (FUN02), which are selectable. The Operate Screen is divided into five sections. • Sections A and B display status information • Sections C and D display the meters selected by the Meter 1 and 2 parameters, see FUN 01, 02. • Section S displays the source for the start command. (QST 04 / QST 05) SECTION A Stop/Reset Pushbutton SECTION S SECTION C • Stops the starter. • Resets a fault. K n o L I a = 0 .0 A Start Pushbutton S TOPPED V a = 0 V • Starts the starter. Up/Down/Left Pushbuttons SECTION B SECTION D • The arrow keys allow you to move through the parameters. • Change the value of a parameter. • Moves through the list of faults. • Pressing [UP],[Down] allows you to change which group of meter values is monitored. Enter Pushbutton • Allows user to change a parameter. • Stores the change of a parameter. • When in Fault or Event Log, [ENTER] key scrolls through information logged when a • Operating Parameters (see user manual for additional descriptions) fault or event occurred. When an alarm condition exists, [ENTER] scrolls through all active alarms. Menu Pushbutton • • • Scrolls between the operate screen and the available parameter groups. When viewing a parameter, pressing [MENU] jumps to the top of the menu. When a parameter is being edited and [MENU] is pressed, the change is aborted and the parameter’s old value is displayed. BIPC-400100-01 MX3 CARD ASSEMBLY CONSISTS OF BIPC-300055-03 (TOP) & BIPC-300034-02 (BOTTOM) stop reset START menu enter Starters Procedure of Setting Data: Digital Input "DI 1 - 8" Configuration To change Motor FLA from 10 Amps to 30 Amps: From Main Screen QST: Motor FLA 01 10 Amp Press [LEFT] key once so the cursor is over the 1. Press [MENU] and the display shows QST: QST: Motor FLA 01 30 Amp Press [UP] arrow twice to increase value to 30. QST: Motor FLA 01 10 Amp Press [UP] key once to Motor FLA (QST 01) QST: Motor FLA 01 30 Amp QST: Motor FLA 01 10 Amp Press [ENTER] once, the cursor will flash on 0. T Ready Ia=0.0A Stopped Va=480V QST: Jump Code 00 1 menu enter Press [ENTER] enter key to store new I/O 01 . . . . I/O 08 DI 1 Configuration . . DI 8 Configuration value. Press [UP] arrow to change another parameter in QST. Press [MENU] to change another parameter in another group. Press [LEFT] arrow to go back to the main screen. Emergency Overload Reset To perform an emergency overload reset, press [RESET] and [DOWN]. This sets the motor thermal overload content to 0. I/O 10 I/O 11 To reset from a fault condition, press [RESET]. To restore ALL parameters to the factory default settings, go to Miscellaneous commands FUN22 and press [ENTER]. Press [UP] until you read "Factory Rst" and press [ENTER]. Off Stop Fault High Fault Low Fault Reset Disconnect Inline Cnfrm Bypass Cnfrm E OL Reset Local/Remote Heat Disable Heat Disable Ramp Select Slow Spd Fwd Slow Spd Rev Brake Disabl Brake Enable Speed Sw NO Speed Sw NC Relay Output "R1 - 6" Configuration Resetting a Fault Restoring Factory Parameter Settings Description Line Power missing Starter is stopped and no Faults All conditions are good for a start command The motor overload alarm level is above PFN33 The motor overload level has reached 100% A start is not allowed until the motor overload level cools below PFN34 A start is not allowed because control power is too low The time until the next start is allowed. See PFN21 Displays the time until the next start is allowed. See PFN22 Displays when the motor thermistor is overheated or defective Displays the hottest RTD that has tripped the starter Starter tripped on a Fault Starter is on and heating motor Starter is applying kick current to the motor Starter is accelerating the load Starter is applying kick current to the motor in Ramp 2 Starter is accelerating the load in Ramp 2 Starter is in Run mode and Ramp Time has expired Starter is Up To Speed Phase Control or Current Follower mode Starter is decelerating the load In Wye-delta control indicates motor is accelerating in Wye mode Preset slow speed forward Preset slow speed reverse DC Injection Braking Power Outage Ride Through I/O 12 I/O 13 I/O 14 I/O 15 R1-R2 Configuration SPDT form C (resistive) NO NC 5A 3A @ 250VAC 5A 3A @ 125VAC 5A 3A @ 30VDC 1250VA 750VA R3 Configuration 10A at 250VAC 10A at 125VAC 10A at 30VDC 2500VA R4-R6 Configuration SPST-NO form A (res) 5A at 250VAC 5A at 125VAC 5A at 30VDC 1250VA Off Fault FS (fail safe) Fault NFS (non fail safe) Running UTS (up to speed) Alarm Ready Locked Out Overcurrent Undercurrent OL Alarm Shunt FS (fail safe trip) Shunt NFS (non fail safe trip) Ground Fault Energy Saver Heating Slow Spd (slow speed) Slow Spd Fwd (speed forward) Slow Spd Rev (speed reverse) Braking Cool Fan Ctl (cooling fan control) PORT Tach Loss Parameter LCD Description Default Units QST 01 Motor Full Load Amps 10 RMS Amps QST 02 QST 03 QST 04 QST 05 QST 06 QST 07 QST 08 QST 09 CFN 01 CFN 02 CFN 03 CFN 04 CFN 05 CFN 06 CFN 07 CFN 08 CFN 09 CFN 10 CFN 11 CFN 12 CFN 13 CFN 14 CFN 15 CFN 16 CFN 17 CFN 18 CFN 19 CFN 20 CFN 21 CFN 22 CFN 23 Motor Service Factor Motor Running Overload Class Local Source Remote Source Initial Motor Current 1 Maximum Motor Current 1 Ramp Time 1 Up To Speed Time Start Mode Ramp Time 1 Initial Motor Current 1 Maximum Motor Current 1 Ramp Time 2 Initial Motor Current 2 Maximum Motor Current 2 Initial Voltage/Torque/Power Maximum Torque/Power Acceleration Ramp Profile Kick Level 1 Kick Time 1 Kick Level 2 Kick Time 2 Stop Mode Decel Begin Level Decel End Level Decel Time Deceleration Ramp Profile DC Brake Level DC Brake Time DC Brake Delay Slow Speed 1.15 10 Terminal 100 600 15 20 Current Ramp 15 100 600 15 100 600 25 105 Linear Off 1.0 Off 1.0 Coast 40 20 15 Linear 25 5 0.2 Off %FLA %FLA Seconds Seconds Seconds %FLA %FLA Seconds %FLA %FLA % % %FLA Seconds %FLA Seconds % % Seconds % Seconds Seconds % *NOTE: Parameters in bold print are the most commonly used in initial start up.