Download Contents
Transcript
Chapter 8 Faults – Causes – Remedies Operate Digital Fault panel tube descripti display display on Probable cause Remedy Sort long time and needs maintenance; 1.Detect safety circuit, and look over its state; Err 41 E41 Safety circuit off The signal of safety 2.Detect that exterior circuit is cut. power supply 5 is natural or not; Door Err 42 E42 lock cut in running Up limit Err 43 E43 The door lock feedback is cut when lift is running. Detect that the door lock contact is natural or not. The signal of up limit Detect that the up limit is cut when lift is up switch contact is natural running. or not. limit The signal of down Detect that the down signal off limit is cut when lift is limit switch contact is down running. natural or not. signal off in running 5 4 Down Err 44 E44 in 4 running 1.Detect 1st up/down Up/Dow n Err 45 E45 slowdow n switch off Up and slowdown down switch is slowdown switch; 2. Ensure 1st up/down cut at one time when slowdown the elevator stops. characteristic (N.O. or 4 signal N.C.); Re-leveli Err 46 E46 ng abnormit y 1.The speed re-leveling is 0.1m/s; of over 1.Detect the primary , secondary connection 2.Re-levelling ‐ 163 ‐ relay. circuit of lock 1