Download AUDIO PRECISION ATS-2 Datasheet
Transcript
SIGNAL GENERATOR OUTPUTS Waveforms Frequency Range Frequency Accuracy Frequency Resolution Amplitude Range Balanced Unbalanced Amplitude Accuracy Amplitude Resolution Analog Sine Family (Normal, Var Phase, Stereo, Dual, Shaped Burst, EQ), IMD (SMPTE/DIN 4:1, 1:1) Square, Noise, Arbitrary Waveform (Multitone), Special (Polarity, Pass Thru) 2 Hz to 61.6 kHz ±0.0002% Digital Sine Family (Normal, Var Phase, Stereo, Dual, Shaped Burst, EQ, Burst, Offset) IMD (SMPTE/DIN 4:1, 1:1) Square, Noise, Arbitrary Waveform (Multitone), Special (Polarity, Pass Thru, Monotonicity, J-Test, Walking Ones, Walking Zeros, Constant Value, Random) 2 Hz to .50 x SR (Sample Rate) SR/2^23 <250 mVrms to 16.00 Vrms [+26.3 dBu] <250 mVrms to 8.00 Vrms [+20.28 dBu] ±0.09dB [±1.0%] 0.007 dB or 0.60 mVrms, whichever is larger SR/2^23 ±0.001 dB 0.000001% [-160 dB] THD+N1 20 Hz-20 kHz £(0.0009% [-101 dB] + 1.6 mV) Frequency Range 10 Hz–20 kHz Risetime Typically 2.0 ms LF Tone Range HF Tone Range Mix Ratio Residual IMD2 40 Hz to 500 Hz 2 kHz to 60 kHz 4:1 or 1:1(LF:HF) £0.0025% [-92 dB] 40 Hz to 500 Hz 2 kHz to 0.47 x SR 4:1 or 1:1(LF:HF) Length 256 to 16384 points per channel Frequency Range Frequency Resolution DC to 0.47 x SR SR / Length 256 to 16384 points per channel DC to 0.47 x SR SR / Length White, Pseudo-Random, Rectangular PDF, 30 kHz or 60 kHz BW Burst Shaped burst: Raised cosine Source Configuration Balanced (XLR), Unbalanced (XLR and BNC), or Common Mode Test (XLR) Source Impedances (Rs) Balanced or Common Mode Test Unbalanced Output Current Limit Max Output Power into 600W Balanced Unbalanced Output Related Crosstalk (20Hz- 20kHz) Formats Balanced (XLR) Unbalanced (BNC) Optical (ToslinkÒ) Sample Rate Range Word Width Output Amplitude Balanced into 110W Unbalanced into 75W Optical (ToslinkÒ) Audio Analyzer Resolution w/Performance Option Sample Rate w/Performance Option Flatness ±0.01 dB (20 Hz-20 kHz, 500 Hz ref) ANALYZER 2 Hz to SR / 6, in even integer sub-multiples of SR N/A Input Ranges Maximum Rated Input Input Impedance Balanced Unbalanced CMRR3 355mVp to 5.6Vp range 11.2 Vp to 200Vp range Input Related Crosstalk Formats Balanced (XLR) 24-bit sigma-delta 16-bit sigma-delta 28.8ks/s to 108ks/s variable; or 65.536ks/s fixed 8-24 bits 28.8kHz to 100kHz AES/EBU; 64kHz-200kHz Dual Connector AES/EBU 56ks/s to 215ks/s variable; or 131.072ks/s or 262.144 ks/s fixed 355 mVp to 200 Vp in 6.02 dB steps 200Vp, 140Vrms (dc to 20kHz); overload protected in all ranges Nominally 200 kW Nominally 100 kW ³80 dB, 10 Hz–20 kHz ³50 dB, 10 Hz–1 kHz £(-100 dB +3 mV), at 20 kHz AES/EBU (per AES 3-1997); SPDIF-EIAJ; Optical SPDIF-EIAJ per IEC 60958 Per IEC 60958-3 28.8 kHz to 108 kHz per connector 8 to 24 bits Unbalanced (BNC) Optical (ToslinkÒ) Sample Rates Word Width <1 mV-140 Vrms [-118 dBu to + 45.1 dBu] ±0.09 dB [±1.0%] -120 dBFS to 0 dBFS (usable to -140 dBFS) ±0.002 dB [±0.023%] ±0.01 dB, 20 Hz to 20 kHz ±0.01dB, 20 Hz to 20 kHz; ±0.1 dB, 20k to 120 kHz RMS, FAST RMS, or QPK per IEC 468 (CCIR) ±0.002 dB, 10 Hz to 0.45xSR Range With Performance Option Accuracy Resolution > 10 Hz to 30 kHz (SR = 65.536 kS/s) > 10 Hz to 120 kHz ±0.0002% [2 PPM] 0.00001% of SR [0.007 Hz at 65.536 kS/s] < 10 Hz to 0.47xSR Phase Measurement Measurement Ranges Accuracy 10 Hz to 5 kHz 5 kHz to 20 kHz 20 kHz to 50 kHz (With Performance Option) Resolution Analog 180, -90 to +270, or 0 to +360 deg Digital SAME 2 deg, 10 Hz to 0.45xSR 0.01 deg SAME AES3 per AES3-1997 SPDIF-EIAJ per IEC 60958 Per IEC 60958-3 28.8 kHz to 108 kHz per connector 8 to 24 bits A-weighted Dolby 2K IEC 468 (CCIR) 20 kHz LP £ 1.2 mV rms £ 2.0 mV rms £ 5.0 mV rms £ 1.6 mV rms £ -142 dBFS £ -134 dBFS £ -127 dBFS £ -140 dBFS Range 0 to 5.10 Vpp Range 0 to 1.275 Vpp Nominal intensity, not variable Fundamental Range Measurement Range Accuracy 10 Hz to 0.47xSR 0 to 100% ±0.3 dB, 10 Hz to 0.45xSR (no filters selected) £ 0.0009% [-101 dB] + 1.6 mV (with 20 kHz LP) SAME SAME SAME White, Pseudo-Random White, Rectangular PDF, Bandwidth 0.50 x SR Shaped burst: Rectangular envelope, raised cosine Nominally 40W or 150W (200W with option EURZ) Nominally 20W or 50W Typically 50 mA +24.1 dBm (Rs = 40W) +18.4 dBm (Rs = 20W) £(-100 dB + 3 mV) Measurement Range Accuracy (1 kHz) Flatness4 “HiRes” A/D “HiBW”5 A/D Detection Residual THD+N 1-System specification including contributions from both generator and analyzer, 20 kHz measurement bandwidth. 2-System specification with 60 Hz/7 kHz or 250 Hz/8 kHz test signal combinations and Vin ³ 200 mV. 3-CMRR performance below 50 Hz degrades with AC coupling. 4-1 kHz ref. Flatness derates above 5 kHz by an additional ±0.02 dB in the 22.4 V, 45 V, 90 V, and 200 V input ranges. 5-Requires High Performance Option. SAME SAME SAME 2 deg 3 deg 4 deg