Download USER MANUAL
Transcript
USER MANUAL METEO CENTER Figure 10: Installing the sensors • Connect the thermometer to the E-Log datalogger as detailed in section 6.3 Connecting the Sensors to the E-Log. 6.2.2. W IND D IRECTION AND W IND S PEED S ENSOR Once a well exposed site, reasonably free from surrounding obstacles, has been found, the wind direction and wind speed combined sensor should be mounted at a height of 10m from the ground on a special structure, as suggested by the WMO. By positioning the sensor on top of the pole, you can get a rather precise idea of what happens at the PV modules height. Make sure that obstacles, if any, are located at a minimum distance of 10 times the height of the sensor (over 30m in our application). The sensor is supplied with a cup rotor, a weather vane rotor and a 7-pole shielded cable. Do the following to install the sensor: • Mount the cup rotor on the sensor body and fasten it by tightening the internal grub screw on the rotor side with the hex key supplied with the sensor • Mount the weather vane rotor on the sensor body and fasten it by tightening the screw on top of the tacho-anemometer. Make sure that the tooth of the weather vane fits into the special hole on the support pin • Run the screened cable inside the pole and make sure that the 7-pole female connector exits from the pole head • Connect the cable to the sensor • Mount the sensor on the pole head. Set the red tip to north and fasten the sensor by tightening the sensor screws with a 10 metric wrench • Connect the tacho-anemometer to the E-Log as detailed in section 6.3 Connecting the Sensors to the ELog. 21/54