Download Describe of using signaling
Transcript
www.portalpmr.com How to use programming software 1. When you open programming software, you can’t use the programming software, as show in following chart: 2. When you have our product, only use programming cable to contact transceiver with computer, programming software will auto contact with transceiver, as show in following chart: www.portalpmr.com Note: The interface of programming cable should be the same as programming software. FM-channel 1. FM channel code: Corresponding with sixteen channel codes. 2. Rx frequency:Edit according to the local radio frequency, the range is: 87-108MHz. 3. Name of transmitter-receiver: You can edit name of radio frequency which you have set, it can make up with 26 letter ( A-Z), ten number (0-9),the length of transceiver-receiver name at most 6 bits. Edit channel (only react on channel mode) 1. All kind of 0-199 channel information will be show in form. 1) RX frequency: selective range:According to model 2) TX frequency: selective range:According to model 2. CTCSS/DCS encoding and decoding 1) CTCSS Function: CTCSS tone Option:67.0-254.1 Hz 2) DCS Function: DCS tone Option:000-754 Note: D×××N means normally DCS tone, D×××I means reverse DCS tone, you can put off CTCSS and DCS in each channel, select from list. 3. Transmit power Function: Select transmit power Option: High(4W)/ Low(1W) ,1-5 means low power, 6-10 means high power Default:10 4. Channel bandwidth Function: Set frequency working bandwidth Option:12.5KHZ (narrow)/ 25KHZ(wide) Default: 25KHZ 5. PTT-ID PTT ID: Select way of transmit PTT ID(BOT/EOT/BOTH) 。 www.portalpmr.com Option: BOT/EOT/BOTH 1) BOT: When press [PTT], transceiver will transmits ID code at the beginning of transmitting. 2) EOT: When release [PTT], transceiver will transmits ID code at the end of transmitting. 3) BOTH: Transceiver will transmit ID code at the beginning or at the end. Default: OFF 6. Optional signaling Function: Select signaling mode Option: WDTS/DTMF / 2TONE / 5TONE Default: WDTS 7. Mutemode Function: Mutemode means the way of open speaker Option: QT/AND/OR 1) QT: When transceiver receives a signaling which can open squeal or suited sub-tone, then it will open speaker. If transceiver doesn’t set sub-tone, it only needs to receive a signaling which can open squeal that also can open the speaker. 2) AND: When transceiver receives the signaling of QT and has suited signal order, then it will open speaker. 3) OR: When transceiver receives one signaling suited QT or AND, it will open the speaker. Default: QT 8. Busy channel lockout Function: After switch on this function, it can prevent to disturb other transceivers which are communicating, if the channel which you have set has been used by other transceiver, then you could not transmit, when press [PTT]. Option: ON/OFF Default: OFF 9. Voice encrypt compress Function: Using voice encrypt compress, when on communication it can reduce noise, make the voice more clear. Option: ON/OFF Default: OFF 10. Add scanning Function: This function means whether ensure to add the frequency of stored channel to scanning list or not; Option: ON/OFF Default: ON 11. Scrambler Function: Means encrypt communication, using scrambler, it can avoid other transceivers which do not use scrambler to hear clear what you talk, but at the same time you also could not hear clear other’s which do not use scrambler. Option: ON/OFF Default: OFF 12. Signaling information Function: This function is destined for signaling code of which edit signaling. www.portalpmr.com Option: 1~15 Default: 1 13. Channel name Function: Edit channel name. Option: Can make up of 26 letters (A~Z, ten number(0~9). Default: Blank Optional parameter only react on frequency mode 1. Transmit over timer Function: The TOT is designed for to prevent your radio to continual transmit too a long time, when transceiver is exceeding the preset time limited, it will stops transmit and give you a prompt voice. Option: 15~600 seconds Default: 60 seconds 2. Transmit overtime alarm Function: Transmit overtime alarm is set for the user that when he/she will reach the time set of TOT, then give a voiceprompt and light will flicker during transmit. Option: OFF/1~10 Default: 5 3.Squelch level Function: Set squelch level is that keeps the speaker silent when there is no signaling. When the squelch level is set all right, then you will hear voice only transceiver receives signaling. If the squelch level set too high, then the signaling should be strong enough that transceiver can receive. Option: 0~9 Default: 5 4. Voice guide Function: Select kind of voice guide. Option: English/ Chinese/OFF Default: English 5. Power on display Function: Select the display of power on Option: Full display/Welcome/Voltage Default: Full display www.portalpmr.com The following chart only react A segment on frequency mode Shift direction Function: Select receive frequency is higher (+) or lower (-) than transmit frequency Option: OFF/+/Default: OFF Offestfrequency Function: Offsetfrequency is dispersion frequency between receive and transmit Option: 0~99.950MHz Default: 0.6MHz The following chart only react B segment on frequency mode www.portalpmr.com Currently working mode Frequency/channel: Means when you have finished set transceiver, when restart transceiver, to work on frequency mode or channel model. Channel number: Means edit the number of this transceiver channels. Channel mode Setting MENU: Means whether turn on MENU function or not on channel mode. Reset: Means whether turn on reset function on channel mode. Synchronous display: Means whether display A/B segment at the same time. DTMF sidetone Function: Means whether turn on speaker or not when transmit DTMF sidetone, and hear a suited DTMF sidetone from speaker. Option: KEY:Switch on sidekey tone, when transmit. ANI:Switch on ANI ID sidetone, when transmit. BOTH:Switch on sidekey tone and ANI ID sidetone, when transmit. OFF:Turn off all Default: KEY VOX Function: When check a voice, switch to transmit mode. Option: OFF/1~10 Default: OFF www.portalpmr.com Auto backlight Function: The time of turn on backlight Option: OFF/1~5 Default: 3 Ring mode Function: After transceiver receives a suited signaling, it will give a voice prompt Option: SOUND:Switch on ring time BIV:Switch on libration BOTH:Switch on both ring and libration OFF:Turn off all Default: SOUND Ring time Function: When it exceeding to the preset value of ring time, speaker will turn on. Option”0~10 Default: 5 Scan mode Function: Transceiver will stop scan when detects a signaling frequency or stored channel. According to you select restart, transceiver will go on scan or stop scan. Option: TO:After signal on channel disappears, the transceiver will start scanning if you do not have any operation within 5 seconds CO:Transceiver will stop scan when searches a signaling, it will go on scanning after signal disappears 3 seconds SE:Scanning will stop when receives a signal Default:TO Delay VOX Function: The purpose of setting VOX delay time is made transceiver return to RX mode after calling, whether the last part of calling can be transmit or not, in order to avoid this problem, then you can set a propriety delay time, make calling can be transmitted completive. But be care, do not set delay time too a long time. Option:0~20 ms Default: 15 ms Beep prompt Function: Beep prompt is to tell you whether transceiver is run well or run wrong or has an malfunction. We kindly advice you to switch on this function www.portalpmr.com Option: ON/OFF Default: ON Keyboard lock/auto lock Function: Lock keyboard Option: ON/OFF Default: OFF Busy channel lockout Function: After switch on this function, it can prevent to disturb other transceivers which are communicating, if the channel which you have set has been used by other transceiver, then you could not transmit, when press [PTT]. Option: ON/OFF Default: OFF Savemode Function: This function will turn off RX circuit for a minute (can set), then after a minute it will turn on and detect signaling. Option: OFF1:1/1:2/1:3/1:4(Means the impulse of turn on and turn off of RX) Default: 1:2 Delay transmit ID Function: If repeater does not respond to the ID which transmit from transceiver, then you can adjust this parameter. Option:: 0~2000 ms Default: 600 ms Switch on frequency modulation radio Function: Defined whether switch on radio Option: ON/OFF Default: ON Defined sidekey Function: Set function of sidekey 1. FM:FM radio function key 2. CALL:Currently signaling calling key www.portalpmr.com 3. NO-SUB:Cancel receiving CTCSS/DCS signaling 4. JP-PRI:Switch to priority channel scan 5. JP-EMC:Switch to alarm channel >>When FM radio on working, and currently frequency or channel still on standby, if receives a signaling, it will auto switch to transceiver. After signaling disappears 5 seconds, it will auto back to FM radio, if you want to exit FM, please press sidekey 1again. >>You can edit FM radio channel by programming software, make the FM radio display FM frequency and name, When you have successful edited, press sidekey to switch on FM radio, then you can use the channel knob to switch FM radio, or use the UP or DOWN to switch. If the model doesn’t have channel knob, you can use the UP or DOWN to switch. Defined topkey Function: Set function of topkey 1. EMCALL: Turn on alarm function 2. CALL01-CALL15: Signaling calling Defined MoNI key Function: Defined for turn on squelch circuit. 1. CONTIN: Do keep press sidekey 2, then turn off squelch circuit. 2. PRESS:Press sidekey 2 one time, then turn off squelch circuit. Standby display color Function: Defined for transceiver backlight on standby. Option: Purple/Blue/Orange Default: Purple Receive display color Function: Defined for transceiver backlight on receiving. Option: Purple/ Blue/Orange Default: Blue Transmit display color Function: Defined for transceiver backlight on transmitting. Option: Purple/Blue/Orange Default: Orange Switching mode password Function: Means that whether set password to switch between frequency mode and channel mode. Option: 0~9 Default: 000000 Set working range password Function: Limited transceiver working range Option: 0~9 www.portalpmr.com ANI ID code Function: Use to send information to receiver, when alarm, allcall, groupcall or selectcall. Option: 0~9 Default: 80386 NOTE >>Due to ANI ID code of this transceiver has difference of 3 bits, 4 bits and 5 bits, so using any one of transceivers in group should be set the same. Length of code Function: Edit bit of ANI ID code Option: 3~5 Default: 5 This transceiver using level Function: Means currently transceiver the right of using range Option: Normally use/Forbid transmitting/ Forbid transmitting and receiving Default: Normally use Monitor priority channel Function: Whether switch on priority scan Option: ON/OFF Default: OFF NOTE >>This transceiver priority channel scan can selectable from 0-199. >>There is only display an “S” on LCD screen, that means transceiver has started priority channel scan. >>Start priority channel scan needs two condition: 1)Do priority channel scan switch on. 2)This function only scan channels which has been stored. >>On frequencmode, channelmode or on scanning, when transceiver detects signaling on priority channel scan, it will transfer the priority channel, if you don’t do any operation after signaling disappears 3 seconds, transceiver will back to primary frequency and resume priority scan. >>The speed of start or resume priority scan, is relate with the time of setting auto backlight. When the time of auto backlight be set as “1”, the speed of start or resume priority scan will be the fastest. >>When priority channel scan which has been set parameter receives signaling, then only the suited frequency, transceiver can transfer priority channel. www.portalpmr.com >>The transferred priority channel only can be used communication, you can’t do any other operation until resume primary frequency. Emergency calling type Function: Means the type of emergency calling Option: ALARM:Field alarm ENI:Distant alarm BOTH:Field + distant alarm Default: BOTH NOTE >>On frequencymode/channelmode, only type of emergency calling be set as ENI and BOTH, then can use the alarm channel to alarm. >>On frequencymode/channelmod, if you don’t set alarm channel, then it will alarm at present channel or frequency Alarm channel Function: Select one of channel which has been edited to emergency alarm. Option: CH-000~CH199 Default: CH000 Switch on dual-standby Function: Means whether to make A/B segment standby at the same time. Option: ON/OFF Default: ON Select type of transmit after switch on dual-standby Function: When switch on dual-standby, select to transmit on A segment or on B segment. Option: A segment/B segment Default: A segment Describe of using signaling Allcall, groupcall, selectcall This transceiver has function of transmit ANI ID code, edit ANI ID code and DTMF decoding, When without other communication equipment, it can accomplish the operation of allcall, groupcall and selectcall. How to use allcall, groupcall and selectcall 1. Edit ANI ID code NOTE: Using any one of transceivers in group should edit difference ANI ID code. ANI ID code: ANI—XXX ANI—XXXX ANI—XXXXX(total has three methods) www.portalpmr.com XXX:Means can edit 3 bits ANI ID code XXXX:Means can edit 4bits ANI ID code XXXXX:Means can edit 5 bits ANI ID code X XXXX Group list A unique ANI ID code 0~9 groups From 0000 to 9999 maximum This is how build up ANI The details of edit method see user’s manual ANI code edit. 2. Setting allcall, groupcall and selectcall NOTE: Using any one of transceiver in group should be set WDTS optional signaling. Setting WDTS optional signaling, the details see user’s manual setting optional signal. 3. Mutemode should be set as AND. The details of method see user’s manual setting mutemode. 4. Press PTT to transmit, according to you need, you can set time one of the BOT/EOT/BOTH, the details see user’s manual MENU 25 5. Turn on ring time alarm and set ring time (according need). The details of method see user’s manual: MENU 30 and MENU 31. 6. Setting PTT-LT: According to present condition, set delay time of transmit code, the details see user’s manual MENU 26 NOTE >>Using any one of transceiver in group, the frequency or channel must be set the same. A. Using allcall: Press [PTT] to transmit, after transmitting ANI ID code, input SCAN + directly # by keyboard. B. Using groupcall: Press [PTT] to transmit, after transmitting ANI ID code, input [ group No. ] + SCAN + SCAN directly by keyboard. C. Using selectcall: Press [PTT] to transmit, after transmitting ANI ID code, input ANI ID code you want to call directly from keyboard. NOTE >>This transceiver has memory function, after you used allcall, groupcall, and selectcall, then you want to transmit again, the ID code is the same as last time you transmitted. If you want to transmit new ID code, please press before transmitting. >>This transceiver has difference of 3 bits, 4bits and 5bits, so all transceiver’s ANI ID code in group has www.portalpmr.com T I X E DTMF、2TONE、5TONE SCAN 1. When DTMF/2TONE/5TONE is set as one frequency, then press PTT to transmit DTMF/2TONE/5TONE. 2. When one channel has been set DTMF/2TONE/5TONE, the preset function will act only transceiver receives a matching DTMF/2TONE/5TONE signaling. 3. Setting signaling 1) NOTE: Using any one of transceivers in group should be set DTMF/2TONE/5TONE optional signaling, the details of setting optional signaling see user’s manual MENU 23. 2) Setting sidetone: The details see user’s manual MENU 16, according to you need to select. 3) Mutemode should be set as AND, the details of method see user’s manual MENU 24. 4) Setting PTT: Depend on your requirement to select one of BOT/EOT/BOTH, see user’s manual MENU 25. 5) Setting S-INFO: The information of receiver and transmitter should be set the same. 6) Setting PTT-LT: according to present condition, set delay time of transmit code, the details see user’s manual MENU 26. Describe of setting 2tone: www.portalpmr.com Encoding Information code Function: Edit serial number of transmit ID code. Option: 1~15 First frequency Function: 2-tone has fifteen serial number, edit first frequency of transmit ID code Option: 300Hz~3000Hz Second frequency Function: 2-tone has fifteen serial number, edit second frequency of transmit ID code Option: 300Hz~3000Hz The time of transmit first frequency Function: The time of transmit first tone of 2tone. Option: 0~1000 ms Default: 600 ms The time of transmit second frequency Function: The time of transmit second tone of 2tone Option: 0~1000 ms Default: 600 ms The time between 2 frequencies Function: The time between first tone and second tone of the 2tone. Option: 0~1000 ms Default: 600 ms www.portalpmr.com Decoding Decoding(There are the same of Decoding 1、Decoding 2、Decoding 3、Decoding 4) The way make up of 2tone: There has twelve methods to make up of 2tone: A-B/ A-C/ A-D/ B-A/ B-C/ B-D/ C-A/ C-B/C-D/ D-A/ D-B/ D-C/ The way of respond to decoding 2tone: When you have succeed of decoding Prompt/Revert/Prompt and revert. A tone[Hz]: Select range: 300~3000 Hz B tone [Hz]: Select range: 300~3000 Hz C tone [Hz]: Select range: 300~3000 Hz D tone [Hz]: Select range: 300~3000 Hz Reset time [ms]: 100~8000ms 2tone, there has 4 ways to respond: Nothing/ www.portalpmr.com Standard Standard frequency of 5tone (5-TONE) This transceiver has fifteen 5tone international standard can be selectable: CCIR1、CCIR2、PCCIR、 ZVEI1、ZVEI2、ZVEI3、 PZVEI、DZVEI、PDZVEI、EEA、EIA、EURO、CCITT、NATEL、MODAT Standard name You can view the corresponding tone of fifteen 5 tone international standard, as show in following chart www.portalpmr.com Encoding Information code Function: Edit serial number of transmit ID code. Option: 1~15 First frame encoding(there are the same encoding of first frame, second frame and third frame) Function: Edit transmitting ID code Option: 0~9 Using standard Each information code has sixteen standard encoding can be selectable. Option: ZVEI1, ZVEI2, ZVEI3, PZVEI, DZVEI, PDZVEI, CCIR1, CCIR2, PCCIR, EEA, EUROSIGNAL, NATEL, EIA, MODAT, CCITT, USER DEFINED Default: CCIR1 NOTE: The standard of encoding and decoding, information code and information encoding should be the same, then you can decode. Delay time before transmit first code: The delay time of transmit first frame 5tone, during this time it only allows carrier wave signaling. Option: 0-1000 ms Default: 400 ms Delay time before transmit second code: The delay time of transmit second frame 5tone, during this time it only allows carrier wave signaling www.portalpmr.com Option: 0-1000 ms Default: 200 ms Delay time before transmit third code: The delay time of transmit third frame 5tone, during this time it only allows carrier wave signaling Option: 0-1000 ms Default: 200 ms Expand time of first tone in each group code: The time of transmit first tone of each frame. Option: 0-1000 ms Decoding Information code Function: Edit serial number of transmit ID code Option: 1~15 Using standard Each information code has sixteen standard decoding can be selectable. Option: ZVEI1, ZVEI2, ZVEI3, PZVEI, DZVEI, PDZVEI, CCIR1, CCIR2, PCCIR, EEA, EUROSIGNAL, NATEL, EIA, MODAT, CCITT, USER DEFINED Default: CCIR1 First frame decoding(there are the same of first frame, second frame and third frame) Function: Edit transmitting ID code www.portalpmr.com Option: 0~9 Function: Option: 1. 2. 3. 4. 5. 6. 7. Call: Receiving matching 5tone, turn on squelch to communicate Monitor: Receiving matching 5tone, auto transmitting. Inspection: Receiving matching 5tone, reply transmitter. Emergency: Receiving matching 5tone, turn on alarm function. Stun: Receiving matching 5tone, couldn’t transmit. Kill: Receiving matching 5tone, could not receive and transmit. Revise: Receiving matching 5tone, revive the stunned or killed transceiver.