Download EPS ZF System
Transcript
Regulations In the opinion of the BBA, the Brillux EPS ZF System, if used in accordance with the provisions of this Certificate, will meet or contribute to meeting the relevant requirements of the following Building Regulations: The Building Regulations 2010 (England and Wales) Requirement: A1 Loading Comment: Requirement: B4(1) External fire spread The system can sustain and transmit wind loads to the substrate wall. See section 6.4 of this Certificate. Comment: The system is designated Class 0 and can, therefore, meet this Requirement. See sections 7.1 to 7.3 and 7.5 of this Certificate. Requirement: C2(b)(c) Resistance to moisture Comment: Requirement: L1(a)(i) Conservation of fuel and power Walls incorporating the system can meet this Requirement. See section 9.3 of this Certificate. Comment: The system can enable, or contribute to enabling, a construction to meet the Target Emission Rate. See sections 5.1 and 5.3 of this Certificate. Requirement: Regulation 7 Materials and workmanship Comment: The system is acceptable. See section 12.1 and the Installation part of this Certificate. The Building (Scotland) Regulations 2004 (as amended) Regulation: 8(1)(2) Fitness and durability of materials and workmanship The use of the system satisfies the requirements of this Regulation. See sections 11.1 and 12.1 and the Installation part of this Certificate. Comment: Regulation: Standard: 9 1.1 Building standards — construction Structure Comment: Standard: 2.6 Spread to neighbouring buildings The system can sustain and transmit wind loads to the substrate wall. See section 6.4 of this Certificate. The system has a ‘low risk’ surface classification but incorporates materials which would not be classed as ‘non-combustible’. Completed walls, therefore, would be regarded as unprotected areas as defined in this Standard, with reference to clauses 2.6.1(1)(2), 2.6.2(1)(2), 2.6.4 (1)(2), 2.6.5(1) and 2.6.6(2). See sections 7.1 to 7.3 and 7.5 of this Certificate. Comment: Standard: 2.7 Standard: 3.10 3.15 Condensation Walls insulated with the system can satisfy the requirements of this Standard, with reference to clauses 3.15.1(1), 3.15.4(1) and 3.15.5(1). See sections 10.6 and 10.7 of this Certificate. Comment: Standards: Precipitation Walls insulated with the system can satisfy this Standard, with reference to clauses 3.10.1(1)(2) and 3.10.6(1)(2). See section 9.3 of this Certificate. Comment: Standard: Spread on external walls The system incorporates materials which would not be classed as ‘non-combustible’ as defined in this Standard under clauses 2.7.1(1)(2) and 2.7.2(2) and should not, therefore, be used on walls one metre or less from a boundary. See sections 7.1 to 7.3 and 7.5 of this Certificate. Comment: 6.1(b) 6.2 Carbon dioxide emissions Building insulation envelope The system can contribute to satisfying these Standards, with reference to all or parts of clauses 6.1.1(1), 6.1.2(1)(2), 6.1.3(2), 6.1.5(2), 6.1.6(1), 6.2.1(1), 6.2.3(1), 6.2.4(1), 6.2.5(1)(2) and 6.2.10(2). See sections 5.1 and 5.3 of this Certificate. Comment: (1) Technical Handbook (Domestic). (2) Technical Handbook (Non-Domestic). The Building Regulations (Northern Ireland) 2000 (as amended) Regulation: B2 Fitness of materials and workmanship Comment: Regulation: B3(2) Suitability of certain materials Comment: Regulation: C4(b) Resistance to ground moisture and weather Comment: Regulation: C5 Condensation The system is acceptable. See section 12.1 and the Installation part of this Certificate. The system is acceptable. See section 11.1 of this Certificate. Walls insulated with the system can satisfy this Regulation. See section 9.3 of this Certificate. Walls insulated with the system can satisfy the requirements of this Regulation. See sections 10.6 and 10.7 of this Certificate. Comment: Regulation: D1 Stability Comment: Regulation: E5(a) External fire spread Comment: The system can sustain and transmit wind loads to the substrate wall. See section 6.4 of this Certificate. The system has a Class 0 classification surface and can satisfy this Regulation. See sections 7.1 to 7.3 and 7.5 of this Certificate. Page 2 of 16