Download USER`S GUIDE
Transcript
User's Guide A.9 More about program editors This chapter contains useful information about editing features, which are common to all the ISaGRAF program editors. This mainly concerns links with other ISaGRAF tools and common ISaGRAF dialog boxes. A.9.1 Calling other ISaGRAF tools Verify (compile) the program The "File / Verify" command runs the ISaGRAF code generator to verify the programming syntax of the currently edited program. In case of SFC language, both level 1 and 2 are checked. When syntax verification is complete, the code generator window must be closed to continue work on the program. If there is only one program in the application (the edited one) the application code is generated if no syntax error is detected. The "Options / Compiling options" command is used to set compiling and optimising parameters. Refer to chapter "Using the code generator" in this document for further information about compiling and code generation. Simulate or debug the application The "File / Simulate" and "File / Debug" commands run the ISaGRAF graphic debugger either in simulation or real connected mode, and re-opens the edited SFC program in debug mode. Used in debug mode, no modification can be entered in the program. Editing the dictionary of variables The "File / Dictionary" command is used to edit the dictionary of variables for the current application and the current program. It also contains the entry points to edit the user-defined words. The local declarations or defined words relate to the currently edited program. A.9.2 Parameters of the program When the edited program is a function, a function block or a sub-program, the "File / Parameters" command is used to define its calling and return parameters. This command has no effect if the edited program is a SFC or top level program from section Begin or End. Sub-programs, functions or function blocks may have up to 32 parameters (input or output). A function or sub-program always has one (and only one) return parameter, which must have the same name as the function, in order to conform to ST language writing conventions. The following dialog box is used to describe the parameters of the sub program: ICS Triplex ISaGRAF Inc. A-75
Related documents
5 - Alugas
Programmable Logic Controller PLC300
User`s Manual - BCM Advanced Research
PDF - Motion Control für Einsteiger
Cartão PLC1
User's Manual of ISaGRAF Embedded Controllers
User`s Manual of ISaGRAF Embedded Controllers
SCADAPack E Configurator User Manual
DS800 Development Suite Software
March 1995 - The Quick Answer
User`s Manual of ISaGRAF Embedded Controllers
User`s Manual of ISaGRAF Embedded Controllers