Download connect

Transcript
EVENT
STARTS WHEN...
0959 Tamper keypads ...the Keypad Tamper microswitch 75 or
Seize microswitch 79 trips, or there are at
least two Keypads with the same BPI bus
Address
0960 keypadTamper ...the Keypad Tamper microswitch 75 or
LED Seize microswitch 79 trips, or there are at
least two Keypads with the same BPI bus
Address
0961 Tamper output ...the Output Expander Tamper microswitch
expanders 101 or Seize microswitch 96 trips, or there
are at least two Output Expanders with the
same BPI bus Address
0962
Tamper power ...the Tamper microswitch or Sieze Tamper
stations Microswitch switch of a Power Supply Station is tripped
0963 Tamper wireless ...the Tamper switch or Snatch switch of a
device VectorRX Receiver is tripped
ENDS WHEN...
...the Tamper and Seize microswitches of
all Keypads restore, and NO two Keypads
have the same BPI bus Address12
...the Tamper and Seize microswitches of
all Keypads restore, and NO two Keypads
have the same BPI bus Address12
...the Tamper and Seize microswitches of
all Output Expanders restore, and NO two
Output Expanders have the same BPI bus
Address 12
...the Tamper and Snatch switches of all
Power Supply Stations are closed
...the Tamper and Snatch switches of all
VectorRX Receivers are closed
Table 7 Control panel events
Ø if the Partition is Armed in Stay mode, the Control Panel
will send the respective Digital Communicator call but
WILL NOT activate the Output associated with the Event;
Ø if the Partition is Armed in Away mode, the Control
Panel will send the respective Digital Communicator
call; if the Digital Communicator call is unsuccessful,
the Control Panel WILL activate the Output associated with the Event.
Dialler Actions CANNOT be associated with
+ The
the Tamper alarm on partition (VDS) no.Customized Event Settings
... low
BATTERY
... charge
... onset
Monostable
OUTPUT
... on standby
ON time
... onset
Low battery
EVENT
... end
OFF
time
OFF
time
ON time
Figure 43 Operations of Generic Events associated with Monostable Outputs
EVENT
STARTS WHEN...
0964 Warning readers ...an enrolled Reader does not respond to
the Control Panel
0965 Warning BPI
...an enrolled Input Expander does not reinput expander spond to the Control Panel
0966 Warning
...an enrolled Keypad does not respond to
keypads
the Control Panel
0967
Missing LED .an enrolled LED Keypad does not respond
Keypad to the Control Panel
0968 Warning output ...an enrolled Output Expander does not reexpanders
spond to the Control Panel
0969 Warning power ...an enrolled Power Supply Station does
stations
not respond to the Control Panel
ENDS WHEN...
...ALL Readers respond to the Control
Panel
...ALL Input Expanders respond to the Control Panel
...ALL Keypads respond to the Control
Panel
ALL LED Keypads respond to the Control
Panel
...ALL Output Expanders respond to the
Control Panel
....ALL Power Supply Stations respond to
the Control Panel
Table 8 Generic Events (continued on next page) —
KYO320
PROGRAMMING
61