Download connect
Transcript
EVENT STARTS WHEN... 0959 Tamper keypads ...the Keypad Tamper microswitch 75 or Seize microswitch 79 trips, or there are at least two Keypads with the same BPI bus Address 0960 keypadTamper ...the Keypad Tamper microswitch 75 or LED Seize microswitch 79 trips, or there are at least two Keypads with the same BPI bus Address 0961 Tamper output ...the Output Expander Tamper microswitch expanders 101 or Seize microswitch 96 trips, or there are at least two Output Expanders with the same BPI bus Address 0962 Tamper power ...the Tamper microswitch or Sieze Tamper stations Microswitch switch of a Power Supply Station is tripped 0963 Tamper wireless ...the Tamper switch or Snatch switch of a device VectorRX Receiver is tripped ENDS WHEN... ...the Tamper and Seize microswitches of all Keypads restore, and NO two Keypads have the same BPI bus Address12 ...the Tamper and Seize microswitches of all Keypads restore, and NO two Keypads have the same BPI bus Address12 ...the Tamper and Seize microswitches of all Output Expanders restore, and NO two Output Expanders have the same BPI bus Address 12 ...the Tamper and Snatch switches of all Power Supply Stations are closed ...the Tamper and Snatch switches of all VectorRX Receivers are closed Table 7 Control panel events Ø if the Partition is Armed in Stay mode, the Control Panel will send the respective Digital Communicator call but WILL NOT activate the Output associated with the Event; Ø if the Partition is Armed in Away mode, the Control Panel will send the respective Digital Communicator call; if the Digital Communicator call is unsuccessful, the Control Panel WILL activate the Output associated with the Event. Dialler Actions CANNOT be associated with + The the Tamper alarm on partition (VDS) no.Customized Event Settings ... low BATTERY ... charge ... onset Monostable OUTPUT ... on standby ON time ... onset Low battery EVENT ... end OFF time OFF time ON time Figure 43 Operations of Generic Events associated with Monostable Outputs EVENT STARTS WHEN... 0964 Warning readers ...an enrolled Reader does not respond to the Control Panel 0965 Warning BPI ...an enrolled Input Expander does not reinput expander spond to the Control Panel 0966 Warning ...an enrolled Keypad does not respond to keypads the Control Panel 0967 Missing LED .an enrolled LED Keypad does not respond Keypad to the Control Panel 0968 Warning output ...an enrolled Output Expander does not reexpanders spond to the Control Panel 0969 Warning power ...an enrolled Power Supply Station does stations not respond to the Control Panel ENDS WHEN... ...ALL Readers respond to the Control Panel ...ALL Input Expanders respond to the Control Panel ...ALL Keypads respond to the Control Panel ALL LED Keypads respond to the Control Panel ...ALL Output Expanders respond to the Control Panel ....ALL Power Supply Stations respond to the Control Panel Table 8 Generic Events (continued on next page) — KYO320 PROGRAMMING 61