13 Station Measurement
13 Station Measurement
License required
The results of this measurement are saved as an binary file and are also available after restarting the appli cation.
Correct assignment of the measured signal levels to the individual stations requires correct setting of the
bus system used (CAN type).
The "Station Measurement" realizes the most important measuring function of CANtouch® - the station-related physical measurement of the physical bus characteristics. For a detailed description, refer to Section
16 " Meas. the Physical Bus Characteristics per Station".
13.1
List of stations
The station scan determines automatically, depending on the bus system selected (CAN type), all transmitting stations or IDs transmitted on the bus and enters them in a list. This list is the basis for further station-related measurements. Tap "Station Scan" to create a list of stations to be measured. Station already
existing in the list will not be deleted.
Tap a station and subsequently
to move the station within the list. Tapping
from the list. To delete the complete list, tap and hold your finger on
removes the station
.
13.2 “All Stations” measurement
This measurement provides a quick overview of the signal conditions of all stations at the bus. The measured quality value is displayed clearly in a bar diagram for each station. Any minimum and maximum values are also marked
graphically so that variations can be recognized easily. This view also displays
minimum and maximum values for the quality level, together with a time stamp.
Tap "Start" to start a new measurement.
Tap a bar in the diagram to select a station. If more than 8 stations are contained in the list, you may also switch to further stations by wiping to the left or
right over the bars.
Document: 22580-HB-1-0-E-CANtouch
15