Download Panasonic KW Series Eco Power Meters
Transcript
Compact Power Meter Eco-POWER METER KW SERIES Conforming to EMC Directive (Excluding KW1M-R) Recognition (KW4M only) Certified (Some models only) Get In-depth Support for Saving Energy by Visualizing Each Power Consumption Inverter air-conditioning power consumption visualization STO RE Refrigerating power consumption and temperature* visualization * When analog input is used NEW NEW Lighting power consumption and illumination* visualization KW2G Eco-POWER METER Standard type KW2G-H Eco-POWER METER SD memory card type KW2G / KW2G-H * When analog input is used Eco-POWER METER Expansion unit (Power measurement and Pulse output) IP66 KW1M Eco-POWER METER Standard type KW1M-H Eco-POWER METER SD memory card type (Master unit) (Slave unit) KW1M-R Eco-POWER METER Built-in wireless type KW7M Eco-POWER METER DIN rail KW4M Eco-POWER METER DIN□48 KW8M Eco-POWER METER DIN48×96 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] Visualizing energy consumption is the first step toward energy savings. Install Eco-POWER METERs in lighting equipment, air conditioners, and production equipment to measure power consumption and check the current status. Then, with specific targets in place, the implementation and management of an energy savings plan is quick and simple. Visualizing target achievments improves the energy usage cycle and allows for changes to be made to maximize efficiency. Inverter air-conditioning power consumption visualization Refrigerating power consumption and temperature* STO RE visualization * When analog input is used Lighting power consumption and illumination* visualization BEFORE * When analog input is used AFTER 1 Measurement 2 Use condition analysis Energy saving cycle 4 Implementation and management of an energy saving plan 3 Energy saving target setting 3 year warranty Factory Automation Devices Products Market Trend Company direction To reduce the usage of earth's resources, Pursue and supply high quality standard demand for a longer product lifecycle increases. products which can be safely used in long term. * Please refer to our website for warranted products and extent of 3 year warranty. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] Steps KW SERIES TYPICAL APPLICATIONS S Schools and supermarkets, etc. Small retailers e.g. convenience stores STORE Convenience stores Lighting 100 V CT CT CT CT CT RS485 KW8M DLL or DLU 3F CT Air-conditioning CT Air-conditioning Lighting Plants Schools and supermarkets Display cases for freezers and refrigerator 200 V Plants with large equipment CT RS485 KW2G KW1M-R KW1M-R RS232C CT Manufacturing equipment DLL or DLU RS485 KW2G KW2G CT CT 2F CT CT Lighting KW4M KW7M RS485 KW2G CT CT CT KW1M LAN CT LAN DLL or DLU CT CT RS485 DLL or DLU PC 1F RS485 KW2G RS232C KW2G RS232C CT KW1M-R LAN PC You can add only the required number of units in a small switchboard. Ideal for small stores. Connector-expandable type KW2G Eco-POWER METER Display cases for freezers and refrigerator DLL or DLU Wiring work not required. Ideal if the layout is frequently changed. (Master unit) Built-in wireless type KW1M-R Eco-POWER METER PC Mountable on a panel surface. Applicable to 400 V equipment. Panel surface mount type KW8M Eco-POWER METER Mountable on a panel. Waterproof (IP66). Waterproof type (Slave unit) KW4M Eco-POWER METER You can add only the required number of units, preventing waste. Designed for DIN rail mounting, ideal for installation in a panel. Panel-mount DIN rail type Connector-expandable type KW7M Eco-POWER METER KW2G Eco-POWER METER Expandable for large equipment with multiple power supplies. Connector-expandable type KW2G Eco-POWER METER Easy when you want small-scale visualization or for trial runs Easy to measure. You can immediately check data on a PC. Easily measure multiple circuits, immediately view results on a PC screen. SD memory card type SD memory card type KW1M-H Eco-POWER METER KW2G-H Eco-POWER METER Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] Selection Guide KW SERIES Eco-POWER METER SELECTION GUIDE Needs ■ Need to measure power of general- purpose CT installed at facility ■ Need to measure high current circuits ■ Need to measure multiple points ■ Need to measure micro-power such as standby power ■ Need to measure existing equipment without line stoppage ■ Need to load analog data or pulse data Recommended model KW8M 1 A / 5 A CT input type • Capable of direct input from 1 A / 5 A CT in the secondary side and up to 4,000 A CT in the primary side without using a dedicated CT KW2G Series • Expandable, as needed, to up to 7 expansion units. • Able to measure micro-power. • Simple measurement function enables measuring CT power only. • The environmental conditions and power can be monitored by using expansion units. (Analog input and pulse input types) ■ Need to simply visualize data on Eco-POWER METER ■ Need to reduce initial costs ■ Need to use the Eco-POWER METER for trials ■ Need alternative cable communications (RS485 and LAN) ■ Need to measure three-phase four-wire systems ■ Need to collect data wirelessly ■ Need to reduce installation costs and man-hour of data collection ■ Need to flexibly alter equipment layout ■ Need to bypass cabling difficulties ■ Need waterproofing for use of water ■ Need to monitor demand ■ Need low-cost power meter ■ Need capability to measure 200 V three-phase three-wire system, etc. KW1M-H / KW2G-H • Main unit has built-in memory. • Transfer of data to SD memory card allows visualization on PC screens, and with the KW2G-H, no wiring needed except for operating power supply. KW1M Series (except AKW1110) and KW8M Series • Direct measurement even of three-phase, four-wire 400 V AC system can be done without VT. KW1M-R • Installation costs reduced because no wires are needed for communications. • Auto routing system for easy wireless set up • RS485 connection enables other Eco-POWER METERs to be ready for wireless communications. KW4M • IEC IP66 certified protective structure KW1M-H / KW8M High performance type • Built-in simple demand function • Alarm outputs when demand target value is exceeded. * Demand function of Eco-POWER METER is that of Japanese specifications. KW1M (AKW1110), KW4M and KW7M • Space-saving design at a reasonable price achieve visualization. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] KW SERIES USEFUL FUNCTIONS 1 A / 5 A CT input type When you want to use a general-purpose CT Without using a dedicated CT, direct input from up to 4,000 A CT in the primary side, 1 A or 5A CT in the secondary side is possible. KW8M 1 A / 5 A CT input type You can measure with a direct connection to an already-installed large-capacity general-purpose CT. Other Eco-POWER METER Series KW8M 1 A / 5 A CT input type When taking dedicated CT measurements of more than 600 A When taking large-capacity general-purpose CT measurements of more than 600 A Breaker Breaker Power source K Secondary side current Power source Short circuit or less than 0.1 Ω resistance CT (Secondary side current: 5 A) K Secondary side current AKW4801C CT (Secondary side current: 1 A / 5 A) L L L Production equipment K K CT is not required. L AKW8115 Production equipment AKW8111 Eco-POWER METER Series accuracy does not include CT error. For dedicated CT measurements of more than 600 A, two CTs are necessary, but since the 1 A / 5 A CT input type KW8M, direct input from a single CT is possible, and you can carry out measurement with higher accuracy than provided by other Eco-POWER METER Series models. For measurements of less than 600 A, measurement from a single CT, whether dedicated or general-purpose, is possible. Inverter (primary side) measurement function For measurement of inverter power supply equipment introduced for saving energy Owing to general susceptibility to high frequency interference, it is said to be difficult to accurately measure power supplied by inverters. Entire Eco-POWER METER Series *Only Eco-POWER METERs with power measurement function Our customers expressed strong demand for a line-up of Eco-POWER METERs that would enable measurement of inverter power supplies (primary side). Ideal for measuring inverter power for large equipment, lighting, etc. Compressor Molding machine Application example Lighting Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] USEFUL FUNCTIONS Unit expansion possible function Up to 8 units! expandable to suit conditions of use without waste! No.1 No.2 Main unit ( No.3 Expansion Expansion unit unit Power Power measurement measurement and Pulse output ) ( No.4 ) Expansion unit (Pulse input) No.5 No.6 Expansion unit (Analog input) No.7 You can get pulse output from each measurement circuit No.8 Application example Expansion unit (AKW2160G) can be used to monitor integrated electric power value according to measured power or to issue alarms from pulse output, and can be controlled by PLC or other host system. Using pulse output it is easy to connect to other companies’ equipment with pulse input functions. Pulse output Pulse input equipment Pulse output Air-conditioning such as PLC, etc. Display cases for freezers and refrigerator Alarm output can be used to trigger warning light flashes. Main unit CT CT Power measurement Power measurement Expansion unit Power measurement and Pulse output Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] KW SERIES Easy wire-saving expandability brings diversity of measurement KW2G KW2G-H Eliminate excess wiring by using up to seven expansion units to add-on the required number of CT inputs for your application. 8 units in total Connector for easy expansion! Up to 7 expansion units can be added Main unit Expansion unit Wiresaving Up to 16 circuits ( Wiresaving! Power supply Space saving ) Single-phase two-wire system Measurement data CT CT CT CT CT CT CT CT CT CT CT CT CT CT CT CT Maxi- 16 circuits (single-phase two-wire system) mum 8 circuits (single-phase three-wire system and three-phase three-wire system) Connectable to various sensors as well as electric power Application example Air/water consumption, temperature, humidity, illumination and other environmental conditions along with power can be monitored by using expansion units for pulse/analog input. ■ Power measurement • Main unit (AKW2010G) • Main unit (AKW2020G) • Expansion unit (AKW2110G) • Expansion unit (AKW2160G) ■ Pulse input ■ Analog input • Main unit (AKW2010G) = one input • Expansion unit (AKW2182G) = two inputs • Main unit (AKW2020G) = one input • Expansion unit (AKW2152G) = two inputs Air Flow Monitor EWA1 Office area Light sensor Air Flow Monitor EWA1 Factory area 28°C Thermometer Motion sensor 28°C Distribution board Motion sensor × 2 Power measurement: 1 point Pulse input: 2 points Temperature × 1 Illumination × 1 Analog input: 2 points Air Flow Monitor EWA1 Compressor × 2 Power measurement: 2 points Integrated flow data × 2 Instantaneous flow data × 2 Pulse input: 2 points Analog input: 2 points Main unit Main unit Expansion unit Expansion unit Pulse input Analog input Power measurement Pulse input Analog input USEFUL FUNCTIONS SD memory card function Easy to implement, visualization of energy usage made easy! KW1M-H KW2G-H Measurement data is automatically saved to an SD memory card. Data collection is possible without a network. • Data can be saved at intervals of 1, 5, 10, 15, 30, or 60 minutes. • Previous power usage is displayed on screen (For KW1M-H: up to 1.5 years worth, for KW2G-H: up to 8 days worth). • Lithium battery backup eliminates worries during power outage. • Data is stored to memory of main unit when an SD memory card is not inserted. Measurement data that is saved to the SD card can be easily displayed in graph form using the free KW View software tool. • No complicated settings are required. Data from multiple Eco-POWER METERs can be compared in a single graph. • In addition to electrical power, create comparison graphs for pulse data or analog data loaded by KW2G-H expansion unit (pulse input type and analog input type). Ideal for switchboards or embedded devices Application example SD memory card compatibility enables economical implementation without the need to set up an external data loggers and a LAN or other network connection for measuring and storing the data. Takes only a small space in an electrical switchboard or embedded device and is ideal for small-scale measurement. For a small space KW1M-H CT KW View For measurements at remote locations Production equipment Application example Using the free KW Watcher software, you can simultaneously graph data stored in the Data logger as well as on the SD memory card. LAN RS485 Analog CT Pulse KW2G-H DLL KW1M Air Flow Monitor EWA1 KW Watcher Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] KW SERIES Wireless capability Easy wire-saving in existing facilities where wiring is difficult KW1M-R Going wireless reduces the labor and installation cost for implementation 10% Cost of power meter 90% Labor and installation cost About half! Cost of wiring materials and labor 15% Cost of power meter 20 to 30% Labor and installation cost * Based on internal research Actual costs depend on site conditions. Wireless auto routing allows easy communications setting via the built-in screen. Using RS485 connection also enables wireless communications other Eco-POWER METERs besides the KW1M-R Master unit Wired devices can also be integrated into the network Slave unit KW8M Automatically build a wireless network You can connect to up to 99 MEWTOCOL devices, 247 MODBUS (RTU) devices (incl. slave units). RS485 Ideal for installation where wiring is difficult or where equipment layout flexibility is required Application example DLL Storing data (logging) RS485 Wirelessly surveillance in-store electric power KW1M-R Eco-POWER METER (Built-in wireless type) Master unit RS485 CT Wall-mounted type KW1M display cases for RS485 Eco-POWER METER freezers and refrigerator (Standard type) KW Watcher CT KW1M-R Eco-POWER METER (Built-in wireless type) Slave unit CT RS485 LAN In-place type display cases for freezers and refrigerator CT * Up to 99 Eco-POWER METERs can be connected. Remote surveillance reduces man-hour *Please contact our sales offices for more information about which areas this product can be used. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] USEFUL FUNCTIONS Micro-power measurement function You can even visualize standby power Standby power is a key to saving energy By understanding both operating power and standby power, you can reduce non-operational energy wastage and initiate power-saving activities that go beyond what was formerly possible. KW2G KW2G-H KW2G and KW2G-H can also measure fine currents. When the load current declines, micro-power measurement mode is automatically activated (auto range switching function). Before With improvement Measurement of standby power Wastage eliminated Integrated electric power (kWh) Integrated electric power (kWh) Standby power Operating power Operating power Measured load Measured load Simple measurement function For existing equipment that must stay switched on and sequential measurement KW2G Ideal for existing facilities where it is better not to switch off equipment and for sequential measurement KW2G-H Application example No power supply wiring needed for the measuring the load! Because connection to the CT is possible, electric power measurement can be done without powering down the equipment. STEP1 Phase and wire system setting (for each unit) STEP2 Set simple measurement mode STEP3 Voltage and power factor setting (common to each unit) 100 V AC CT STEP4 Set simple measurement mode Power source for main unit Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] KW SERIES Simple demand function Affordable peak demand control! Estimate power consumption peak demand and get support for power management and cost-efficiency. KW1M-H KW8M High performance type Operation overview of simple demand control Alarm output and display Estimated demand (kW) Demand value (kW) Demand target value (kW) The simple demand function averages electric power during 30-minute periods and estimates demand on a per-minute basis. Present demand (kW) P t Remaining time (T - t) t Start Demand period T (minute) 0 minute 15 minutes Finish * Not compatible with pulse input. 30 minutes Only works with CT input (power measurement). * The demand function of Eco-POWER METER is that of Japanese specifications. Demand control for cost-efficiency Application example If demand exceeds present demand or estimated demand target values, an alarm alerts the customer. For onsite surveillance • Light up an alarm lamp • When demand exceeds limit value, alarm signals by a buzzer, graded flashing lights, etc. On-screen display and more intense flashing Power measurement Switchboard CT Alarm output (Pulse output) For remote surveillance RS485 Customer • Able to control power load within demand target value • ON/OFF demand status is informed through RS485 communication *Simple demand should be treated as a rough guide. Power-use scheduling is set by the Eco-POWER METER. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] Performance PERFORMANCE COMPARISON Main unit Product name KW2G : Available ○ — : Not available Expansion unit KW2G-H KW1M Standard type KW2G / KW2G-H Standard type SD memory card type Power measurement Power measurement and Pulse output Pulse input Analog input KW1M-H SD memory card type Appearance Model No. Mounting method Dimensions (mm inch) (W × H × D) DIN rail (sold separately) Screw installation Mounting frame (sold separately) In panel mounting On panel mounting DIN DIN DIN DIN DIN DIN AKW2010G AKW2020G AKW2110G AKW2160G AKW2152G AKW2182G 50×95×65 1.97×3.74×2.56 ○ ○ — ○ — — — Phase and wire system Input measured voltage (Select with setting mode) Single-phase two-wire system Single-phase three-wire system Three-phase three-wire system Three-phase four-wire system — Communication ○ — — 100 to 240 V AC 100/200 V AC system ○ ○ ○ ○ ○ ○ — Load measurement for 400 V AC system (Note 1) Current transformer (CT) — ○ Operating power supply — ○ ○ ○ — ○ ○ ○ — — External voltage transformer (VT) required. Dedicated type: 5 A, 50 A, 100 A, 250 A, 400 A and 600 A Interface ○ ○ ○ ○ — — ○ — — — — — — — — — — — — — — — Screw AKW1110 ○ — — ○ — ○ — — ○ — ○ — — ○ 25×95×65 0.98×3.74×2.56 DIN Frame AKW1111 75×90×50 2.95×3.54×1.97 ○ ○ ○ ○ DIN Screw Frame AKW1121 ○ ○ ○ ○ ○[Mounting frame (sold separately) is required.] 100/200 V AC system ○ ○ ○ — External voltage transformer (VT) required. 100/200/400 V AC system ○ ○ ○ ○ ○ ○ ○ ○ Transformer not required Direct input possible Dedicated type: 5 A, 50 A, 100 A, 250 A, 400 A and 600 A Conforming to RS485 Communication protocol MEWTOCOL/MODBUS (Selectable with setting mode) Restrictions apply. Please check communication specifications column. Number of connected units 99 (max.) 1 point 1 point — — 2 points — — 1 point 1 point Number of pulse output point 1 point 1 point — 1 point — — 1 point 1 point 1 point Number of analog input point (Note 3) — — — — — 2 points — — — — Excess alarm output Number of pulse input point (Note 2) Instantaneous active electric power Current value Stand-by electric power Preset value Demand (Note 4) ○ ○ ○ ○ — Main unit memory function — External memory function — Calendar timer function — Simple measurement Integrated electric power Instantaneous electric power Measuring items Current Voltage Electricity charge (Note 5) Conversion carbon dioxide value Power factor Frequency Hour meter Pulse count value Tool and software (free of charge) Simultaneous power and pulse measurement KW Monitor KW Watcher KW View KW Network monitor Standard ○ ○ ○ ○ ○ — — — — — — — — — — — — — — — — — — ○ (Active) ○ ○ ○ ○ — — CE and S-MARK — ○ ○ ○ ○ ○ — — ○ ○ ○ ○ — — — — — — — — — — — — — — ○ ○ ○ (Active, Reactive, Apparent, Regenerative) ○ (R, N/S, and T) ○ (RS, RT, and TS) ○ ○ ○ ○ Displayed on Displayed on the main unit the main unit ○ ○ ○ ○ — ○ ○ — — — ○ ○ ○ ○ ○ ○ ○ — — — — — — — ○ ○ — — — — — — — — — — — — — — — — — — — — — CE CE and S-MARK — — ○ ○ (Note 6) — ○ ○ ○ ○ ○ ○ ○ ○ — — — — CE CE and S-MARK — ○ When connected to AKW2020G — — ○ (Active) ○ (Active) ○ (R and T) ○ (R and T) ○ ○ — Notes: 1) A VT (secondary side rated voltage: 110 V) is needed to measure loads that exceed rated input voltage. 2) Input method: contact/non-voltage contact (open collector) 3) To set input range of analog input unit using setting mode and select voltage 0 to 5 V/1 to 5 V, current 0 to 20 mA/4 to 20 mA. 4) The demand function of Eco-POWER METER is that of Japanese function. 5) Eco-POWER METER is primarily designed for managing energy saving. It is not intended to be used for billing. 6) Displayed on the main unit — — — — — ○ ○ ○ ○ ○ ○ ○ ○ — ○ (Active) ○ (Active) ○ (Active) ○ (Active) ○ (R, S, and T) ○ (R, S, and T) ○ (R, S, and T) ○ (RS, RT, and TS) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ — ○ — CE and S-MARK — KW SERIES : Available ○ — : Not available Product name KW1M-R Built-in wireless type (Note 1) KW4M DIN□48 KW7M DIN rail MEWTOCOL type KW8M DIN48×96 MODBUS type High performance type 1A/5A CT input type Frame Frame AKW8111H AKW8115 Appearance DIN * Screw DIN Model No. Mounting method Dimensions (mm inch) (W × H × D) Master unit Slave unit AKW1000 AKW1131 75×90×50 2.95×3.54×1.97 (Excluding the antenna) ○ ○ DIN rail (sold separately) Screw installation Mounting frame (sold separately) — On panel mounting ○ Phase and wire system — — Three-phase three-wire system — Three-phase four-wire system — — Current transformer (CT) — Communication Load measurement for 400 V AC system (Note 2) Number of connected units AKW8111 48×96×98.5 1.89×3.78×3.88 — ○ ○ [Terminal socket (sold separately) is required.] ○ — — 100/200/400 V AC system — Single-phase three-wire system Communication protocol AKW5112 AKW5212 ○ ○ ○ ○ — — — — — — ○ ○ ○ ○ ○ ○ — 100 to 240 V AC Single-phase two-wire system Interface Frame ○ Operating power supply Input measured voltage (Select with setting mode) Screw 22.5×75×100 Screw terminal type: 48×48×81.9 1.89×1.89×3.22 0.89×2.95×3.94 11-pin type: 48×48×87.5 1.89×1.89×3.44 ○ — Frame AKW5111 AKW5211 AKW7111 — ○ In panel mounting DIN *Terminal socket (sold separately) is required. 100/200 V AC system ○ ○ ○ ○ ○ ○ ○ — External voltage transformer (VT) required. ○ ○ ○ ○ ○ ○ ○ ○ Transformer not required. Direct input possible. Dedicated type: 5 A, 50 A, 100 A, 250 A and 400 A Conforming to RS485/RS232C — 100/200/400 V AC system ○ ○ ○ — Transformer not required. Direct input possible. Dedicated type: 5 A, 50 A, 100 A, 250 A, 400 A and 600 A — Dedicated type: 5 A, 50 A, 100 A, 250 A, 400 A and 600 A (Note 4) Conforming to RS485 MEWTOCOL/MODBUS (Selectable with setting mode) Restrictions apply. Please check communication specifications column. MEWTOCOL/MODBUS (Selectable with setting mode) MEWTOCOL MODBUS MEWTOCOL/MODBUS (Selectable with setting mode) Restrictions apply. Please check communication specifications column. MEWTOCOL: Up to 99 units MODBUS: Up to 247 units 99 (max.) — 1 point — 1 point 1 point 1 point 1 point 1 point Number of pulse output point — 1 point 1 point 1 point 1 point 1 point 1 point 1 point Number of analog input point — — — — — — — Instantaneous active electric power — Current value — Stand-by electric power — Preset value — Demand (Note 5) — Excess alarm output Number of pulse input point (Note 3) ○ ○ ○ ○ ○ ○ ○ — — — — — — — ○ — — ○ ○ ○ — — Main unit memory function — — — — — — External memory function — — — — — — — — — — — — — — — — Calendar timer function Measuring items Simple measurement — Integrated electric power — Instantaneous electric power — Current — Voltage — Electricity charge (Note 6) — Conversion carbon dioxide value — Power factor — Frequency — Hour meter — Pulse count value — Simultaneous power and pulse measurement Tool and software (free of charge) ○ — KW Monitor — KW Watcher — KW View — KW Network monitor Standard ○ — — — ○ ○ ○ ○ ○ ○ — ○ — — ○ ○ ○ ○ — — — — — ○ (Active) ○ (Active) ○ (Active) ○ (Active) ○ (Active, Reactive, Apparent) ○ (Active) ○ (Active) ○ (Active) ○ (Active) ○ (Active, Reactive, Apparent) (R, S, and T) (CT1 and CT2) (CT1 and CT2) (CT1 and CT2) ○ ○ ○ ○ ○ (CT1, CT2, and CT3) (between 1 and 2, ○ (between 1 and 2, ○ (between 1 and 2, (between P1 and P0, between P2 and P0, between P3 and P0) ○ (RS, RT, and TS) ○between ○ 2 and 3) between 2 and 3) between 2 and 3) ○ ○ ○ ○ ○ ○ ○ — — — — ○ ○ ○ — — — ○ ○ ○ ○ — — — ○ ○ ○ ○ — ○ ○ ○ ○ ○ ○ — ○ ○ ○ ○ ○ ○ — — — ○ ○ ○ ○ — ○ ○ ○ ○ ○ ○ — ○ ○ ○ ○ ○ ○ — — (Note 1) ○ — — — — — — — — — — — — CE and S-MARK CE, UL, and S-MARK Notes: 1) Please contact our sales offices for more information about which areas this product can be used. 2) A VT (secondary side rated voltage: 110 V) is needed to measure loads that exceed rated input voltage. 3) Input method: contact/non-voltage contact (open collector) 4) Commercially available current transformer (CT) (When using secondary current 1 A or 5 A and when primary current is 4,000 A or less) 5) The demand function of Eco-POWER METER is that of Japanese function. 6) Eco-POWER METER is primarily designed for managing energy saving. It is not intended to be used for billing. CE and S-MARK Tool & Software SOFTWARE TOOL KW View For KW1M-H / KW2G-H For easy visualization of measurement data collected by an SD memory card Verification Display tool Power CO2 Charge Pulse Analog ■ Simply load the measurement data (CSV file) collected in an SD/SDHC memory card into your PC. You can then display the data as a graph by month, day and hour, and print it out. ■ Using easy operation, you can manage Eco-POWER METER data for up to 99 units. ■ KW1M-H graph shows display is in 60 minutes units (fixed). KW2G-H graph shows display is in 15, 30 or 60 minutes units (fixed). ■ Data for integrated electric power, pulse data (count values), analog data (converted to digital values) can now be displayed graphically. ■ Automatic device recognition. KW1M-H SD memory card type Before and after chart of integrated electric power KW View KW2G-H SD memory card type PC * Analog data (converted digital values) are only displayed on the graph for each hour. KW Watcher Graph comparing integrated electric power KW View and temperature (analog) Compatible with all products (if data is stored by DLL or DLU) For easy “visualization” of data collected in DLL and DLU* Measurement monitoring software Management ■ Collected files stored according to unit of time on the Data Power CO2 Charge Analog Primary unit Time set OK logger, are downloaded as required to a PC and graphs and numerical data can be displayed for simple electric power, water amount, temperature, primary unit and air flow amount measurement values. ■ Measurement is in 15 min, 30 min, and 60 min units. ■ KW1M-H / KW2G-H data stored on SD memory cards can also be displayed. (Requires change of KW Watcher settings) Pulse Before and after chart of integrated electric power KW Watcher LAN RS485 KW2G *DLL is the abbreviation for Data Logger Light. DLU is the abbreviation for Web Datalogger Unit. DLL PC Electric power use broken down by facility KW Watcher KW1M KW4M Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] KW SERIES All software tool can be downloaded*, free of charge, from our website. You can also check the required operating environments. *Customer registration is required before you download. KW Monitor For easy visualization of real-time Eco-POWER METER data Software for centralized control by PC Analysis and Eco-POWER METER setting ■ You can directly access the Eco-POWER METER via your PC. Data can be constantly collected and easily displayed numerically or in graph form. ■ Logging can be selected among 1 sec, 5 sec, 10 sec, 15 sec, 30 sec, 60 sec, 1 min, 5 min, 10 min, 15 min, 30 min, and 60 min units. (Depending on communication conditions and number of connections, data may not be acquired for the collection period.) ■ Electrical power can be measured either integrated or instantaneous. ■ With simple demand functions both logging and demand estimation can be performed simultaneously. Display of warning messages according to target value settings is useful for energy management. ■ Data for integrated electric power, pulse data (count values), analog data (converted to digital values) can now be displayed graphically. ■ Communication protocol compatibility only with MEWTOCOL Eco-POWER METER setting Integrated / Instantaneous power CO2 Charge Pulse Analog Current Voltage Weld time Power factor Frequency Counter Demand Time set OK Terminal setting Graph showing hour integrated value and total integrated value KW Monitor LAN RS485 KW2G KS1 Signal Converter KW7M PC * KW2G series units are also able to directly connect one-to-one with a PC via USB port. KW8M ■ For each Eco-POWER METER, settings can all be set, changed, or stored on a PC. (Storage of setting values is possible only, via USB transfer, with the KW2G series.) ■ Since changes can be made to multiple Eco-POWER METERs at the same time, the labor of setting units one at a time is saved. Setting screen KW Monitor KW Network Monitor For wireless network tree check Built-in wireless type For KW1M-R Software for wireless network check Verification ■ This software is useful for making the “visualization” of network at the time of installation or occurrence of a problem. ■ You can check the connection status of the wireless network and the terminal devices by connecting your PC to the master unit and carrying out simple operations, which will help you to quickly resolve problems. ■ This software can read out an error log stored in KW1M-R (master unit). Wireless network confirmation screen KW Network Monitor Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] Specifications KW2G / KW2G-H Main unit * AKW2020G and AKW2160G have only CE certification marking. Expansion unit AKW2010G AKW2020G KW2G KW2G-H KW2G / KW2G-H COMMON FEATURES ●Up to 7 expansion units can be added as required without need for power or other wiring. Up to 16 circuits (single-phase two-wire) or 8 circuits (single-phase threewire; three-phase three-wire) ●If an expansion unit (pulse input and analog input type) is used, flow, temperature, humidity and other environmental conditions can be monitored. ●By using an expansion unit (power measurement and pulse output), pulse output is possible for each measuring circuit. ●Capable of various types of measurement. Simultaneous measurement of regenerative power (instantaneous), micro-power, inverter power (primary side), electrical power and pulse (flow, etc.) AKW2110G AKW2160G AKW2152G AKW2182G FEATURES OF KW2G-H ●Simple measurement function enables measurement of electric power of only the CT. ●Via USB connection with a PC, using KW Monitor, you can easily check initial settings and operating status. ●Quick installation: The units fit DIN rails. ●Pulse output width can be freely set in the range of 1 to 100 ms; finer power values can be output to an external counter. ●Because pulse input status is displayed, the operational status of external connected devices can be monitored. ●Internal memory Automatic logging function (read by SD memory card). Automatic logging of measurement data on expansion units. ●Built-in battery (clock and log data backup). ORDER GUIDE Product name Phase and wire system Operating power supply Input measured voltage Current transformer (sold separately) Main unit (Standard type) KW2G / KW2G-H EcoPOWER METER Single-phase two-wire system Dedicated type 100 to 240 V AC 100 / 200 V AC Single-phase three-wire 5 A, 50 A, 100 A, system 50 / 60 Hz system Power measurement 250 A, 400 A, 600 A Three-phase three-wire Power measurement and system Pulse output (Note 1) Expansion Pulse input Number of input points Input method unit 2 channels Contact / No contact (open collector) (Note 2) Analog input Number of input points Input range Voltage: 0 to 5 V / 1 to 5 V (Note 3) Current: 0 to 20 mA / 4 to 20 mA (Note 3) 2 channels (Note 2) Main unit (SD memory card type) Model No. AKW2010G AKW2020G AKW2110G AKW2160G AKW2152G AKW2182G Notes: 1) Use a main unit (standard type) of Ver. 1.04 or later and a main unit (SD memory card type) of Ver.1.01 or later. 2) Use a main unit (standard type) of Ver. 1.02 or later. 3) Select with setting mode MEASUREMENT ITEMS Power measurement (for AKW2010G, AKW2020G, AKW2110G and AKW2160G) Item Unit Data display range Integrated electric power kWh/MWh (Active) (Note 1) Active (Note 2) kW Instantaneous Reactive (Note 2) kvar electric power Apparent kVA R-current A N/S-current A Current T-current A R (RS)-voltage V S (RT)-voltage V Voltage T (TS)-voltage V Electricity charge (Note 3) Conversion carbon dioxide value kg-CO2 Power factor (Note 2) Displayed on the main unit Frequency Hz Pulse count value (Note 4) 0.00 to 9999.99 kWh to 9999.99 MWh, 0.00 to 9999999.99 kWh (when 9-digit display) −9999.99 to 0.000 to 9999.99 −9999.99 to 0.00 to 9999.99 0.00 to 9999.99 0.000 to 6000.00 0.000 to 6000.00 (calculated value) 0.000 to 6000.00 0.0 to 9999.9 0.0 to 9999.9 (calculated value) 0.0 to 9999.9 0.00 to 999999 0.00 to 999999 −1.00 to 1.00 (without identify leading phase and lagging phase) 47.5 to 63.0 0 to 999999 Pulse input (for AKW2152G) Item Pulse count value (Note) Data display range 0 to 999999 Note: The number of displayed digit of pulse count value differs according to the prescale set by pre-scale setting mode. Analog input (for AKW2182G) Item Converted digital value (Note) Data display range −999999 to 999999 Note: The number of displayed digits of the converted digital values differs according to the preset decimal point position. Notes: 1) KW2G / KW2G-H can measure regeneration electric power. Integrated electrical power is not integrated (not subtracted) when detecting regeneration electric power. 2) While detecting regeneration electric power, minus is displayed on instantaneous active electric power and power factor. 3) Eco-POWER METER is designed chiefly to manage saving energy. It is neither intended nor can it be legally used for billing. 4) Displayed digit of pulse counter differs according to the pre-scale set by pre-scale setting mode. SPECIFICATIONS For details, please refer to the Eco-POWER METER user’s manual. Main unit specifications Item Specifications Rated operating voltage Rated frequency Rated power consumption Allowable operating voltage range Allowable momentary power-off time Ambient temperature Ambient humidity Display method Number of connectable expansion units Power failure memory method Weight 100 to 240 V AC (Add to main unit) 50 / 60 Hz common Main unit: 6 VA, Expansion unit (Power measurement, Power measurement and Pulse output, and Analog input): 0.5 VA / unit, Expansion unit (Pulse input): 1.0 VA /unit (240 V AC at 25 °C 77 °F) 85 to 264 V AC (85 % to 110 % of rated operating voltage) 10 ms -10 to +50 °C +14 to +122 °F (-25 to +70 °C -13 to +158 °F) at storage 30 to 85 % RH (at 20 °C 68 °F), non-condensing LCD with backlight (green), Upper: 5-digit (7-segment 1-digit + 16-segment 4-digit), Lower: 6-digit (7-segment) Max. 7 units EEPROM (more than 1,000,000 overwrite), Memory items: setting value and integral measuring value Main unit (Standard type): 180 g, Main unit (SD memory card type): 185 g, Expansion unit (Power measurement): 80 g, Expansion unit (Power measurement and Pulse output, Pulse input and Analog input): 85 g Electric power input specifications (for AKW2010G, AKW2020G, AKW2110G and AKW2160G) Item Specifications Integrated electric power and Instantaneous electric power Accuracy Current without Voltage error in CT Temperature characteristics and VT Frequency characteristics Within ± (2.0 % F.S. + 1 digit) (at 20 °C 68 °F, rated input, rated frequency, power factor 1) *Accuracy coverage: 10 to 100 % of rated current Within ± (1.0 % F.S. + 1 digit) (at 20 °C 68 °F, rated input, rated frequency, power factor 1) *Accuracy coverage: 10 to 100 % of rated current Within ± (1.0 % F.S. + 1 digit) (at 20 °C 68 °F, rated input, rated frequency, power factor 1) Within ± (1.0 % F.S. + 1 digit) (Range of -10 to +50 °C 14 to 122 °F, rated input, power factor 1) Within ± (1.0 % F.S. + 1 digit) (Frequency change ± 5 % based on rated frequency, rated input, power factor 1) ( ) KW SERIES Memory specifications of main unit (for AKW2020G) Item Specifications 15 min (00 hr. 00 min 00 sec after the day) (fixed) (Instantaneous value) Integrated electric power (1) (2), Instantaneous active electric power (1) (2), Instantaneous reactive electric power (1) (2), Instantaneous File type 1 apparent electric power (1) (2), R-current (1), R (T)-current (2), S (N)-current, R/RS-voltage (1), R (T/TS)-voltage (2), RT-voltage, Power factor (1) (2), (instantaneous Save data Frequency, Count value, Converted digital value for CH0, Converted digital value for CH1, Pulse count value for CH0 and Pulse count value for CH1 value) (Note 1) Save data amount 96 records per file (max. approx. 8 days worth of data) Save cycle 15 min (00 hr. 00 min 00 sec after the day) (fixed) File type 2 Save data (Difference value) Integrated electric power (1) (2), Count value, Pulse count value for CH0 and Pulse count value for CH1 (difference value) (Note 1) Save data amount 96 records per file (max. approx. 8 days worth of data) Select among 1 min, 5 min, 10 min, 15 min, 30 min, or 60 min (Saved timing) When 1 min is selected: 00 sec after the minute When 5 min is selected: 00, 05, 10, 15, 20, 25, 30... min after the hour Save cycle When 10 min is selected: 00, 10, 20, 30, 40, 50 min after the hour When 15 min is selected: 00, 15, 30, 45 min after the hour File type 3 When 60 min is selected: 00 min after the hour (instantaneous value detail) Integrated electric power (1) (2), Instantaneous active electric power (1) (2), Instantaneous reactive electric power (1) (2), Instantaneous apparent (Note 1) Save data electric power (1) (2), R-current (1), R (T)-current (2), S (N)-current, R/RS-voltage (1), R (T/TS)-voltage (2), RT-voltage, Power factor (1) (2), Frequency, Count value, Converted digital value for CH0, Converted digital value for CH1, Pulse count value for CH0 and Pulse count value for CH1 Save data amount Max. 720 records, 12 hours approx. worth of data (when the save cycle is set to one minute) Main unit display Integrated electric power by day (latest data covering 8 days period) / Integrated electric power by hour (latest data covering 12 hours period) Calendar timer function Time accuracy Monthly accuracy: ±30 sec (at 25 °C 77 °F) Content of battery backup Time measurement and Log data Battery life (Note 2) 2 years approx. (at 25 °C 77 °F, in power-off state) Logging functions Save cycle Notes: 1) Using the setting mode, you can select whether or not to write to the SD memory card for each of file types 1, 2, and 3. Files can be created for each unit. 2) When the battery gets low, the BATT display will start flashing. Please replace the battery in accordance with the battery replacing procedure. Also, battery life will be shortened if the main unit is used in a high temperature environment. * While measuring, data is collected in the memory of main unit. If, while measuring, the memory capacity of main unit is reached, data will be overwritten in succession starting from the oldest data. Initialization of the main unit memory is possible. External memory specifications (for AKW2020G) • SD memory card slot Item Specifications Support media Supported format standards SD memory card (Note 1) Compliant with SD and SDHC standards (Note 2) Notes: 1) Operation verified SD memory card: Panasonic Corporation SD/SDHC memory card 2 GB and 4 GB class 4 and over 2) To format SD memory cards, please download and use the formatting software available on the Panasonic website. The file system on a SD memory card that was formatted using standard PC software does not comply with the SD memory card standard. Communication specifications Specifications RS485 communication Item Protocol Transmission function Isolation status Number of connected units Transmission distance Transmission speed Transmission format Communication method Synchronous system Ending resistance <SD memory card handling precautions> Data saved on an SD memory card may be lost in the following cases. Please note that Panasonic Industrial Devices SUNX is not responsible for any losses of recorded data and other direct and indirect damages. 1) When a customer or a third party incorrectly uses the SD memory card 2) When the SD memory card is affected by static electricity or electrical noise 3) When the SD memory card is taken out or the power is turned off while the SD memory card access LED of the unit is flashing (during data writing) * It is recommended that you constantly back up important data to another medium. MEWTOCOL / MODBUS (RTU) (selectable with setting mode) Isolated with the internal circuit 99 units max. (Note 1) (Note 2) 1,200 m 3,937 ft max. (Note 3) 38,400 / 19,200 / 9,600 / 4,800 / 2,400 bps (selectable with setting mode) Data length: 8-bit / 7-bit (selectable with setting mode) (Note 4) Parity: Not available / Odd number / Even number (selectable with setting mode) Stop bit: 1-bit / 2-bit (selectable with setting mode) Half-duplex Synchronous communication method 120 Ω approx. (built-in) USB communication (Note 5) Computer link (MEWTOCOL) Isolated with the internal circuit 12 Mbps (Full-speed) - Notes: 1) For RS485 converter on the computer side, we recommend SI-35 and SI-35USB (from LINE EYE Co.,Ltd.). 2) When using SI-35, SI-35USB or PLC from our company (which can be connected up to 99 units), up to 99 Eco-POWER METER can be connected. [When using C-NET adapter, up to 32 Eco-POWER METER (max.)] In case using this system with the other devices, up to 31 Eco-POWER METER can be connected. 3) Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line. 4) With MODBUS (RTU) protocol, it works only with 8-bit. 5) When using the USB port, install the dedicated USB driver. Pulse input specifications (for AKW2010G, AKW2020G and AKW2152G) Item Input mode Max. counting speed Pulse input (Min. input signal width) Input signal Output mode Decimal point Prescale Range Item Specifications Addition (Fixed) 50 kHz / 30 Hz (Select with setting mode) 0.01 ms (When 50 kHz selected) / 16.7 ms (When 30 Hz selected), ON : OFF ratio = 1 : 1 Contact / No contact (open collector) • Impedance when shorted: Max. 1 kΩ • Residual voltage when shorted: Max. 2 V • Impedance when open: Min. 100 kΩ HOLD (Over count) Setting possible up to under 3-digit 0.001 to 100.000 (Set with setting mode) Number of output point Insulation method Output type / Output capacity Pulse width (when pulse output with integrated active electric power selected) ON state voltage drop OFF state leakage current 1 point Optical coupler Open collector / 100 mA 30 V DC 1 to 100 ms (selectable with setting mode) (Note 1) 1.5 V or less 100 μA or less 0.001 kWh, 0.01 kWh, 0.1 kWh, 1 kWh, 10 kWh, 100 kWh / Power alarm (AL-P) / Current alarm (AL-C) / Stand-by power alarm (AL-S) / Counter (Cnt) (Note 2, 3) Analog input specifications (for AKW2182G) Item Number of input points Input range (Select Voltage with setting mode) Current Converted digital value Resolution Overall precision Voltage Input impedance Current Voltage Absolute maximum input Current Input protection Pulse output (Transistor output) specifications (for AKW2010G, AKW2020G and AKW2160G) Specifications Specifications 2 channels 0 to 5 V / 1 to 5 V (selectable with setting mode) 0 to 20 mA / 4 to 20 mA (selectable with setting mode) 0 to 4000 (decimal number) (Note) 1/4000 (12 bits) ±1 % F.S. or less (-10 to +55 °C +14 to 131 °F) 440 kΩ 125 Ω - 0.3 to +10 V - 2 to + 30 mA Diode Pulse output unit (selectable with setting mode) Notes: 1) Pulse width setting is possible using main unit software AKW2010G Ver. 1.04 or later and AKW2020G Ver. 1.01 and later. 2) For normal operation of other functions, to switch on minimal pulse width of 1 to 10 ms, the maximum pulse output interval is 25 ms. Consequently, a minimum measurable pulse unit output setting of 40 pulses or less per 1 second is recommended. How to calculate Unit for pulse output: PL-P > Max. measurement power (kW) / 3,600 sec × 4 pulse/sec When the pulse output unit is 0.001, the maximum power that can be properly measured by pulse output is 144 kW (3600 sec × 40 pulse/sec × 0.001). Cautions: (1) Count errors may occur if the pulse output is set to 40 pulses or more per 1 second. (2) If the pulse output OFF time is set too short, count errors by connected counters, PLCs (Programmable Logic Controllers) may occur. 3) These count output specifications are only for the main unit. Note: Digital conversion value differs according to the scaling conversion value set by setting mode. If the analog input value exceeds the upper or lower limit, the digital value will preserve the upper or lower limit. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] Feature & Specifications KW1M / KW1M-H / KW1M-R Master unit AKW1111 AKW1110 AKW1121 KW1M AKW1000 KW1M-H KW1M COMMON FEATURES AKW1131 KW1M-R FEATURES OF KW1M-H ● Internal memory (Read by SD memory card) ● Built-in battery (for clock and log data backup) ● Calendar timer function. ● Simple demand function. ● Output of alarm signal is possible using the “alarm setting”. ● 50 mm 1.97 inch thickness makes it perfect for control panel installations. ● Selectable screw, DIN rail and panel installation. ● Display switchable between electrical power and electricity charge usage. ● Display of calculated CO2 value possible ● Measurement of inverter power supplies (primary side) is available. Slave unit FEATURES OF KW1M-R ● Wireless capabilities eliminate need for LAN installation. ● Auto routing system for easy setup of a wireless network. ● Compatible with a wide range of AC power supply and directly installable in a distribution board. ● RS485 connection enables Eco-POWER METERs other than KW1M-R to be ready for wireless communications. ● Calendar timer function. ● Wired/Wireless selection function (AKW1131 only) ● Please contact our sales offices for more information about which areas this product can be used. ORDER GUIDE Product name KW1M (Standard type) KW1M-H (SD memory card type) KW1M-R Built-in wireless type Phase and wire system Single-phase two-wire system Single-phase three-wire system Three-phase three-wire system Three-phase four-wire system (Note 1) - Master unit (Note 2, 3) Slave unit Single-phase two-wire system Single-phase three-wire system Three-phase three-wire system Three-phase four-wire system Operating power supply Input measured voltage 100 / 200 V AC system 100 to 240 V AC 50 / 60 Hz 100 / 200 / 400 V AC system (Select with setting mode) Current transformer (sold separately) Dedicated type 5 A, 50 A, 100 A, 250 A, 400 A and 600 A Model No. AKW1110 AKW1111 AKW1121 - - AKW1000 100 / 200 / 400 V AC system (Select with setting mode) Dedicated type 5 A, 50 A, 100 A, 250 A, 400 A and 600 A AKW1131 Notes: 1) For a three-phase four-wire system, exclude AKW1110 from the selection. 2) AKW1000 can serve as either a “master unit” or a “slave unit (as a repeater)” by being selected in the master unit/slave unit setting mode (MODE 1). 3) AKW1000 does not have a power measurement function. MEASUREMENT ITEMS (Not applicable for AKW1000) Item Instantaneous electric power (Active) Unit kW Data display range 0.00 to 9999.99 0.00 to 9999.99 MWh Integrated electric power (Active) kWh/MWh R-current A 0.0 to 6000.0 S-current (Note 1) A 0.0 to 6000.0 T-current A 0.0 to 6000.0 R (RS)-voltage V 0.0 to 9999.9 S (RT)-voltage (Note 1) V 0.0 to 9999.9 T (TS)-voltage V 0.0 to 9999.9 Electricity charge (Note 2) - 0.00 to 999999 kg-CO2 0.00 to 999999 Current Voltage Conversion carbon dioxide value 0.00 to 9999999.99 kWh (when 9-digit display) Power factor (Note 1) - Frequency (Note 1) - 47.5 to 63.0 Hz ON-time h (Hour) 0.0 to 99999.9 OFF-time h (Hour) 0.0 to 99999.9 Hour meter Pulse count value (Note 1) - 0.00 to 1.00 [Identify leading phase (–) or lagging phase] (Only in range of phase angle θ = –90° to +90°) 0 to 999999 Notes: 1) Excluding AKW1110 2) Eco-POWER METER is designed chiefly to manage saving energy. It is neither intended nor can it be legally used for billing. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] KW SERIES SPECIFICATIONS For details, please refer to the Eco-POWER METER user’s manual. Main unit specifications Item Rated operating voltage Rated frequency Rated power consumption Allowable operating voltage range Allowable momentary power-off time Ambient temperature Ambient humidity Wireless specifications (for AKW1000 and AKW1131) Item Direct sequence spread spectrum (DS-SS) 100 m 328 ft (Obstacle-free straight-line distance) 1 mW 2,405 to 2,480 MHz 16 channels (The auto-scanning function can Number of channels automatically select an unassigned channel.) Wireless transmission speed 250 kbps 1 : N communication, Auto routing system (N: Up to 247 units) Communication style Number of repeaters: 8 repeaters (between the Repeater function master unit and the target slave unit) (Note) Note: Since the unit does not have a repeater setting function, use the dedicated tool “KW Network Monitor” to check the actual number of repeaters. Pulse input specifications (for AKW1111, AKW1121 and AKW1131) Input mode Max. counting speed Pulse input (Min. input signal width) Input signal (at 20 °C 68 °F) Mode Decimal point Range Prescale Specifications Addition (Fixed) 2 kHz / 30 Hz (Select with setting mode) 0.25 ms (When 2 kHz selected) / 16.7 ms (When 30 Hz selected), ON : OFF ratio = 1 : 1 Contact / No voltage contact (open collector) • Impedance when shorted: Max. 1 kΩ • Residual voltage when shorted: Max. 2 V • Impedance when open: Min. 100 kΩ HOLD (Over count) Setting possible up to under 3-digit 0.001 to 100.000 (Set with setting mode) Communication specifications Item Power failure memory method AKW1000 FROM (more than 100,000 overwrite) AKW1110, AKW1111, EEPROM (more than 100,000 overwrite) AKW1112 and AKW1131 170 g approx. (AKW1110 and AKW1111), 180 g approx. (AKW1121), 160 g approx. (AKW1000), 170 g approx. (AKW1131) * Excluding the antenna and battery Weight Electric power input specifications Improved measurement accuracy Item Specifications Integrated electric power and Instantaneous electric power Within ± (2.0 % F.S. + 1 digit) (at 20 °C 68 °F, rated input, rated frequency, power factor 1) Accuracy coverage: 5 to 100 % of rated current Within ± (1.0 % F.S. + 1 digit) (at 20 °C 68 °F rated input, rated frequency, power factor 1) Accuracy coverage: 5 to 100 % of rated current Current Accuracy without error in CT and VT ( ) Voltage Within ± (1.0 % F.S. + 1 digit) (at 20 °C 68 °F rated input, rated frequency, power factor 1) Hour meter Within ± (0.01 % +1 digit) (at 20 °C 68 °F) [In case power on start or current energizing: within ± (0.01 % + 1 sec + 1 digit) (at 20 °C 68 °F)] Temperature characteristics Within ± (1.0 % F.S. + 1 digit) (Range of -10 to 50 °C 14 to 122 °F, rated input, power factor 1) Frequency characteristics Within ± (1.0 % F.S. + 1 digit) (Frequency change ± 5 % based on rated frequency, rated input, power factor 1) Specifications of the pulse output (transistor output) of integrated electric active power Item Number of output point Insulation method Output type Output capacity Pulse width ON state voltage drop OFF state leakage current Pulse output unit (selectable with setting mode) (Note 3) Specifications 1 point Optical coupler Open collector 100 mA 30 V DC 100 ms approx. 1.5 V or less 100 μA or less 0.001 kWh, 0.01 kWh, 0.1 kWh, 1 kWh, 10 kWh, 100 kWh / Power alarm (AL-P) / Current alarm (AL-C) / Stand-by power alarm (AL-S) (Note 1) / Counter output (Cnt) (Note 1) / Demand alarm (OEM) (Note 2) Notes: 1) For AKW1111, AKW1121, and AKW1131 2) For AKW1121 only 3) We recommend the setting of minimum unit for pulse output for measurement shown as below. Output pulse: 4 pulses or less per 1sec Count errors may occur if pulse output unit is set so that 4 or more pulses are output per 1 second. - How to calculate Unit for pulse output: PL-P > Max. measurement power (kW) / 3,600 sec × 4 pulse/sec RS232C communication (for AKW1000 only) Protocol Specifications LCD with backlight Upper: green, 4-digit, 16-segment Lower: amber, 6-digit, 7-segment Display method Specifications Wireless system type Communication distance Radio wave output Frequency band Item Item Specifications 100 to 240V AC 50 / 60 Hz common 6 VA (AKW1110), 8 VA (AKW1111, AKW1121 and AKW1131), 5 VA (AKW1000) (240 V AC at 25 °C 77 °F) 85 to 264 V AC (85 % to 110 % of rated operating voltage) 10 ms -10 to +50 °C 14 to 122 °F (-25 to +70 °C -13 to +158 °F) at storage 30 to 85 % RH (at 20 °C 68 °F), non-condensing Specifications RS485 communication MEWTOCOL and MODBUS (RTU) (Note 5) (Note 6) (selectable with setting mode) Isolated with the internal circuit Max. 99 units (Note 2, 3) 1,200 m 3,937 ft (Note 1) / 38,400, 19,200, 9,600, 4,800 or 2,400 bps 15 m 49 ft / 115,200, 57,600, 38,400, 19,200, 9,600, 4,800, For AKW1000: 115,200, 57,600, 38,400, 19,200, 9,600, 4,800, 2,400 or 2,400 or 1,200 bps (selectable with setting mode) 1,200 bps (selectable with setting mode) Data length: 8-bit / 7-bit (selectable with setting mode) (Note 4), Parity: Not available / Odd number / Even number (selectable with setting mode), Stop bit: 1 bit (fixed) Half-duplex / Synchronous communication method Enable / Disable (selectable with setting mode) (If you enable the flow control function, the counterpart equipment must also be compatible with flow control.) 120 Ω approx. (built-in) MEWTOCOL: 2,048 bytes, MODBUS (RTU): 256 bytes MEWTOCOL: 2,048 bytes (Note 7), MODBUS (RTU): 256 bytes (Note 7) MEWTOCOL and MODBUS (RTU) (Note 5) Isolation status Number of connected units Transmission distance / Transmission speed Transmission format Communication method / Synchronous system Flow control Ending resistance Data buffer (Max. data byte size for send and receive one time) Notes: 1) Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, transmission speed may be different according to using devices or transmission line. 2) For RS485 converter on the computer side, we recommend SI-35 and SI-35USB (from LINE EYE Co., Ltd.). 3) When using SI-35,SI-35USB or our PLC (which can be connected up to 99 units), up to 99 Eco-POWER METER units can be connected. (However, 32 units max. using connection with C-NET adapter) In case using this system with the other devices, up to 31 Eco-POWER METER units can be connected. 4) With MODBUS (RTU) protocol for RS485 communication, it works only with data length 8-bit. 5) You don’t have to select a protocol for the 1:1 communications of AKW1000 (only if both units are AKW1000). 6) AKW1131 cannot be used for data communications via RS485. It may result in malfunction. 7) Command sending to/receiving from an AKW1131 station: Max. reading: 26 points (57 bytes), Max. writing: 23 points (55 bytes) * Modbus Protocol is a communications protocol developed for PLCs by Modicon Inc. Memory specifications of main unit (for AKW1121) Item File type 1 instantaneous value ( File type 2 difference value ( ) File type 3 instantaneous value detail ( ) Save cycle Save data Save data amount Save cycle Save data Save data amount Save cycle ) Save data Save data amount Main unit display Specifications 60 min (on the hour) (fixed) (Instantaneous value) Integrated electric power, Instantaneous electric power, Current, Voltage, Power factor, Frequency, and Count value 24 records per file (max. approx. 1.5 years worth of data) 60 min (on the hour) (fixed) (Difference value) Integrated electric power and Count value 24 records per file (max. approx. 1.5 years worth of data) Select among 1 min, 5 min, 10 min, 15 min, 30 min, or 60 min (Saved timing) When 1 min is selected: 00 sec after the minute When 5 min is selected: 00, 05, 10, 15, 20, 25, 30... min after the hour When 10 min is selected: 00, 10, 20, 30, 40, 50 min after the hour When 15 min is selected: 00, 15, 30, 45 min after the hour When 60 min is selected: 00 min after the hour Integrated electric power, Instantaneous electric power, Current, Voltage, Power factor, Frequency, and Count value Max. 5,760 records, 4 days approx. period (when the save cycle is set to one minute) Integrated electric power by month (latest data covering 1.5 year period) / Integrated electric power by day (latest data covering 1 month period) / Integrated electric power by hour (latest data covering 24 hours period) External memory specifications <SD memory card slot> (for AKW1121 only) Item Support media Supported format standards Specifications SD memory card (Note 1) Compliant with SD and SDHC standards (Note 2) Notes: 1) Operation verified maker: Panasonic Corporation SD/SDHC memory card 2 GB, 4 GB and 8 GB 2) To format SD memory cards, please download and use the formatting software available on the Panasonic website. The file system on a SD memory card that was formatted using standard PC software does not comply with the SD memory card standard. Calendar timer specifications (for AKW1000 and AKW1121) Item Time accuracy Content of battery backup Battery life Specifications Monthly accuracy: ± 240 sec (at –10 °C 14 °F) Monthly accuracy: ± 70 sec (at 25 °C 77 °F) Monthly accuracy: ± 240 sec (at 50 °C 122 °F) Time measurement and log data (for AKW1121) 2 years approx. (at ambient temperature 25 °C 77 °F) (in power-off state) < SD memory card handling precautions > Data saved on an SD memory card may be lost in the following cases. Please note that Panasonic Industrial Devices SUNX is not responsible for any losses of recorded data and other direct and indirect damages. 1) When a user or a third party incorrectly uses the SD memory card 2) When the SD memory card is affected by static electricity or electrical noise 3) When the SD memory card is taken out or the power is turned off while the SD memory card access LED of the unit is flashing (during data writing) * It is recommended that you constantly back up important data to another medium. Feature & Specifications KW4M / KW7M / KW8M KW4M FEATURES Features of KW4M ● Easy on-panel mounting with included mounting frame. ● Protective structure: IEC IP66 (Only the panel front with rubber gasket). ● UL-compliant. ● Measurement of inverter power supplies (primary side) is available. Common Features of KW8M KW7M KW8M KW8M High performance type ● Log data is stored to memory of main unit. ● Built-in battery (for clock and log data backup). ● Simple demand function. ● Compatible with systems of up to threephase four-wire. ● Easy on-panel mounting with included mounting frame. ● Measurement of inverter power supplies (primary side) is available. KW8M 1 A / 5 A CT input type ● Capable of direct input from 1 A / 5 A CT in the secondary side without using dedicated CT. ● High current circuit measurement. Features of KW7M ● DIN rail type ideal for installation in a panel. ● Slim, 22.5 mm 0.89 in wide: easily mounts anywhere. ● Measurement of inverter power supplies (primary side) is available. ORDER GUIDE Product name KW4M Eco-POWER METER DIN □48 type Protocol Phase and wire system Input measured voltage Current transformer (sold separately) Terminal type MEWTOCOL MODBUS (RTU) MEWTOCOL MODBUS (RTU) KW7M Eco-POWER METER DIN rail type KW8M Eco-POWER METER DIN 48 × 96 type Screw terminal Single-phase two-wire system Single-phase three-wire system 100 / 200 V AC system Three-phase three-wire system Dedicated type 5 A, 50 A, 100 A, 250 A and 400 A Single-phase two-wire system Single-phase three-wire system 100 / 200 V AC system Three-phase three-wire system Single-phase two-wire system High performance type Single-phase three-wire system Three-phase three-wire system 1 A / 5 A CT input type Three-phase four-wire system 11-pin Dedicated type 5 A, 50 A, 100 A, 250 A, 400 A and 600 A 100 / 200 / 400 V AC system (Select with setting mode) Model No. AKW5111 AKW5112 AKW5211 AKW5212 Screw terminal (M3 / M2 screw) AKW7111 Screw terminal (M3 “+ / –” screw) AKW8111H AKW8111 U.R.D., Ltd. CTL-CL series separate CT recommended (Check the specifications before use.) AKW8115 (Note) Note: Since a dedicated CT is not used, please use a 4,000 A or less type (secondary current: 1 A or 5 A). MEASUREMENT ITEMS KW4M KW8M Item Instantaneous electric power Integrated electric power L1 (CT1) - phase current L2 (CT2) - phase current Voltage between 1-2 Voltage Voltage between 2-3 Yen Electricity Dollars charge Euros (Note) Yuan No currency Conversion carbon dioxide value ON-time Hour meter OFF-time Pulse count value Current Unit Data display range kW 0.00 to 9999.99 0.00 to 9999.99 kWh and after kWh 10.00 MWh to 9999.99 MWh MWh When 9-digit display: 0.00 to 9999999.99 kWh A 0.0 to 6000.0 A 0.0 to 6000.0 V 0.0 to 9999.9 V 0.0 to 9999.9 JPY 0 to 999999 $ 0.0 to 99999.9 EUR 0.0 to 99999.9 CNY 0 to 999999 CHG 0 to 999999 kg-CO2 0.0 to 999999 h (Hour) 0.0 to 99999.9 h (Hour) 0.0 to 99999.9 Count 0 to 999999 KW7M Item Unit Instantaneous electric power Integrated electric power L1 (CT1) - phase current Current L2 (CT2) - phase current Voltage between 1-2 Voltage Voltage between 2-3 Electricity charge (Note) kW kWh A A V V Data display range 0.00 to 999999.99 0.00 to 9999999.9 0.0 to 6000 0.0 to 6000 0.0 to 9999 0.0 to 9999 0.00 to 99999999 Item Unit Data display range Integrated Active electric Reactive power Apparent Active Instantaneous Reactive electric power Apparent CT1 - phase current CT2 - phase Current current CT3 - phase current Voltage between P1 and P0 Voltage between Voltage P2 and P0 Voltage between P3 and P0 Electricity charge (Note) kWh kvarh kVAh kW kvar kVA 0.00 to 9999999.9 0.00 to 9999999.9 0.00 to 9999999.9 0.00 to 9999999.99 -99999.99 to 0.00 to 999999.99 0.00 to 9999999.99 Power factor Frequency ON-time OFF-time Pulse count value Hour meter A 0.0 to 6000 A 0.0 to 6000 A 0.0 to 6000 V 0.0 to 9999 V 0.0 to 9999 V 0.0 to 9999 0.0 to 99999999 Displayed on 0.00 to 1.00 [with identify leading phase the main unit (LEAD) or lagging phase (LAG)] -1.00 to 0.00 to 1.00 Communication Only in range of phase angle θ = –90° to 0 to +90° Hz 47.5 to 63.0 ( Time - ) 0.0 to 99999.9 0.0 to 99999999 Note: Eco-POWER METER is primarily designed to manage saving energy. It is neither intended nor can it be legally used for billing. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] KW SERIES SPECIFICATIONS For details, please refer to the Eco-POWER METER user’s manual. KW4M Main unit specifications Item Specifications Rated operating voltage Rated frequency Rated power consumption Allowable operating voltage range Allowable momentary power-off time Ambient temperature Ambient humidity Vibration resistance Shock resistance Display method Power failure memory method Protection Weight 100 to 120 V AC / 200 to 240 V AC 50 / 60 Hz common 8 VA (240 V AC at 25 °C 77 °F) 85 to 132 V AC / 170 to 264 V AC (85 % to 110 % of rated operating voltage) 10 ms -10 to +50 °C 14 to 122 °F (-25 to +70 °C -13 to +158 °F) at storage 30 to 85 % RH (at 20 °C 68 °F), non-condensing 10 to 55 Hz (1cycle / min), single amplitude: 0.75 mm 0.03 in (1 hour on 3 axes) Min. 294 m/s2 (5 times on 3 axes) 6-digit, 7-segment (set value) with backlight and 4-digit, 16-segment (mode), LCD upper section: green, lower section: amber EEPROM (more than 100,000 overwrite) IEC standard IP66 (only front panel with rubber gasket) * Mounted in a row, waterproofing property will be lost. 140 g approx. (screw terminal type), 130 g approx. (11-pin type) KW7M Main unit specifications Item Specifications Rated operating voltage Rated frequency Rated power consumption Allowable operating voltage range Allowable momentary power-off time Ambient temperature Ambient humidity Vibration resistance Shock resistance Display method Power failure memory method Weight 100 to 120 V AC / 200 to 240 V AC 50 / 60 Hz common 6 VA (240 V AC at 25 °C 77 °F) 85 to 132 V AC / 170 to 264 V AC (85 % to 110 % of rated operating voltage) 10 ms -10 to +50 °C 14 to 122 °F (-25 to +70 °C -13 to +158 °F) at storage 30 to 85 % RH (at 20 °C 68 °F), non-condensing 10 to 55 Hz (1cycle / min), single amplitude: 0.375 mm 0.01 in (1 hour on 3 axes) Min. 294 m/s2 (5 times on 3 axes) 8-digit, 7-segment LED EEPROM (more than 100,000 overwrite) 100 g approx. KW8M Main unit specifications Item Specifications Rated operating voltage Rated frequency Rated power consumption Allowable operating voltage range Allowable momentary power-off time Ambient temperature Ambient humidity Vibration resistance Shock resistance Display method Power failure memory method Weight (without mounting bracket) 100 to 240 V AC 50 / 60 Hz common 8 VA (240 V AC at 25 °C 77 °F) 85 to 264 V AC (85 % to 110 % of rated operating voltage) 10 ms -10 to +50 °C 14 to 122 °F (-25 to +70 °C -13 to +158 °F) at storage 30 to 85 % RH (at 20 °C 68 °F), non-condensing 10 to 55 Hz (1cycle / min), single amplitude: 0.375 mm 0.01 in (1 hour on 3 axes) Min. 294 m/s2 (5 times on 3 axes) 8-digit, 7-segment LED EEPROM (more than 100,000 overwrite) 235 g approx. (AKW8111), 250 g approx. (AKW8111H high performance type), 265 g approx. (AKW8115 1 A / 5 A CT input type) Note: Analog input terminals: No. 11 to 20 / Pulse input terminals: No. 4 and 5 KW4M / KW7M / KW8M Electric power input specifications Item Improved measurement accuracy Specifications Integrated electric power and Within ± (2.0 % F.S. + 1 digit) (at 20 °C 68 °F, rated input, rated frequency, power factor 1) (Note 1) Instantaneous electric power Accuracy coverage: 5 to 100 % of rated current Within ± (1.0 % F.S. + 1 digit) (at 20 °C 68 °F rated input, rated frequency, power factor 1) Current Accuracy coverage: 5 to 100 % of rated current Accuracy without error in Voltage Within ± (1.0 % F.S. + 1 digit) (at 20 °C 68 °F rated input, rated frequency, power factor 1) CT and VT Within ± (0.01 % +1 digit) (at 20 °C 68 °F) Hour meter (Note 2) [In case power on start or current energizing: Within ± (0.01 % + 1 sec + 1 digit) (at 20 °C 68 °F)] Temperature characteristics Within ± (1.0 % F.S. + 1 digit) (Range of -10 to +50 °C 14 to 122 °F, rated input, power factor 1) Frequency characteristics Within ± (1.0 % F.S. + 1 digit) (Frequency change ± 5 % based on rated frequency, rated input, power factor 1) Notes: 1) Integrated electric power (active/apparent) and instantaneous electric power (active/apparent) of AKW8115: within ± (1.0 % F.S. + 1 digit) (at 20 °C 68 °F, rated input, rated frequency, power factor 1) Accuracy coverage: 5 to 100 % of rated current 2) Excluding KW7M ( ) Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] Option DEDICATED CURRENT TRANSFORMER (CT) AND OPTIONS DEDICATED CURRENT TRANSFORMER (CT) ORDER GUIDE (Dedicated CT cannot be used with the AKW8115.) Primary side rated current AKW4801C 100 A AKW4802C 250 A AKW4803C 400 A AKW4804C 50 A/100 A AKW4506C Clamp-on type Through type Model No. 5 A/50 A 250 A/400 A AKW4507C 600 A AKW4508C (Note 2) Notes: 1) For except AKW8115, please order in accordance with the type of power distribution system you will be measuring. (Even if you will be using a secondary side 5 A CT, you will need an AKW4801C.) 2) AKW4508C can be used with an Eco-POWER METER compatible with 600 A type CT. AKW4801C AKW4802C AKW4506C AKW4803C AKW4804C AKW4507C AKW4508C Specifications Type Model No. Item Primary side rated current Secondary side rated current Winding (Turn) Ratio error Through hole Clamp-on type AKW4802C AKW4803C AKW4801C AKW4804C AKW4506C Through type AKW4507C AKW4508C 5 A/50 A 1.67 mA/16.7 mA 3,000 100 A 250 A 400 A 50 A/100 A 250 A/400 A 600 A 33.3 mA 125 mA 200 mA 16.7 mA/33.3 mA 125 mA/200 mA 200 mA 3,000 2,000 2,000 3,000 2,000 3,000 ± 2.0% F.S. ± 1.0% F.S. ø10 mm ø0.39 in ø16 mm ø0.63 in ø24 mm ø0.94 in ø36 mm ø1.42 in ø17 mm ø0.67 in ø36 mm ø1.42 in Breakdown voltage (initial) 1,000 V AC / 1 min (Between 2,000 V AC / 1 min (Between 2,000 V AC / 1 min (Between 1,000 V AC / 1 min (Between through hole and output lead wire) through hole and output lead wire) through hole and output lead wire) through hole and output lead wire) Insulation resistance (initial) Functional vibration resistance Vibration resistance Functional shock resistance Shock resistance Output protection level Permissible clamping frequency Ambient temperature range Storage temperature Ambient humidity Weight (Trunk cable included) Min. 100 MΩ (at 500 V DC megger) (Between through hole and output lead wire) 10 to 55 Hz (1 cycle / min), single amplitude: 0.15 mm 0.01 in (10 min on 3 axes) 10 to 55 Hz (1 cycle / min), single amplitude: 0.375 mm 0.01 in (1 hour on 3 axes) Min. 98 m/s2 (4 times on 3 axes) Min. 294 m/s2 (5 times on 3 axes) ± 7.5 V with clamp element ± 3.0 V with clamp element ± 7.5 V with clamp element ± 3.0 V with clamp element 100 times approx. ― –10 to +50 °C +14 to +122 °F (without frost and non-condensing) –20 to +60 °C –4 to +140 °F (without frost and non-condensing) 35 to 85 % RH (at 20 °C 68 °F non-condensing) 60 g approx. 90 g approx. 200 g approx. 295 g approx. 70 g approx. 200 g approx. 215 g approx. Notes: 1) Dedicated CT are dedicated for low voltage under 440 V AC system. They can not be used for high voltage circuit. 2) In each type of Eco-POWER METER excluding AKW8115, a combination of commercially secondary side 5 A CTs and dedicated CTs for 5 A (AKW4801C) is used for measuring high voltage circuits; therefore, AKW4801C is definitely necessary. For details, confirm with each respective user’s manual. 3) Since dedicated CTs cannot be used when measuring with AKW8115, please be careful and do not purchase a dedicated CT by mistake. 4) For the AKW8115 CT, current transformers manufactured by U.R.D. Co., Ltd. (clamp-on type CT CTL-CL series) are recommended. Please confirm the specification beforehand. 5) Dedicated CT are not included with Eco-POWER METERs. 6) Each dedicated CT includes a 1 m 3.3 ft trunk cable, respectively. OPTIONS Trunk cable Intermediate power cable Product name Trunk cable for CT Option of EcoPOWER METER dedicated CT Model No. 3 m 9.8 ft 5 m 16.4 ft 10 m 32.8 ft (special order) AKW4703 Product name Model No. AKW4705 Intermediate power cable AKE2811 AKW4710 Note: For any type of trunk cable, please connect no more than one. Antenna with cable: For KW1M-R 200 ± 10 7.87 ± 0.39 Pencil type antenna: For KW1M-R Note: We recommend using an intermediate power cable when attaching the dedicated CT to a non-“Y” split power cable. Antenna extension cable: For KW1M-R (Note) RS232C cable: For KW1M-R (master unit) Cable length: 2 m 6.6 ft One unit * Packed with AKW1000 and AKW1131 Model No.: AKW1803 One unit Model No.: AKW1802 Cable length: 2 m 6.6 ft One unit Model No.: AKW1804 Model No.: AKR1801 Note: When an antenna extension cable is used, radio wavel attenuation occurs. With a single extension cable, the communications distance is reduced by about 30 %: use only after prior confirmation that the system is functioning KW SERIES Required for installation inside switchboard Mounting rails (applicable for DIN and IEC standards): For KW4M pin type (AKW5211 and AKW5212), KW7M, KW2G / KW2G-H, and KW1M / -H / -R Fastening plate: For KW4M pin type (AKW5211 and AKW5212), KW7M, KW2G / KW2G-H, and KW1M / -H / -R 1,000 ± 1 39.37 ± 0.04 5.5 0.22 0.20 0.59 0.39 0.59 0.11R 0.59 0.39 0.59 0.20 5 15 10 15 2.75R 15 10 15 5 Length: 1 m 3.3 ft Aluminum 50 1.97 12 0.47 M4 M0.16 10 0.39 40−5.5×15 0.22×0.59 Oval hole 35 24 1.38 0.94 DIN rail terminal socket: For KW4M 11-pin type (AKW5211 and AKW5212) 1.5 0.06 27 1.06 Model No.: ATA4806 ATA4806 10 0.39 UP Model No.: AT8-DLA1 * For holding DIN rails 7.5 0.30 30.5 1.20 70 2.76 Model No.: ATC180041 50 1.97 Required for installation on control panel 45 1.77 * Sold separately 34.6 1.36 21 0.83 ø31.4 ø1.24 43.4 1.71 Mounting frame: For KW1M and KW1M-H 75.4 2.97 2-19 2-0.75 ø30 ø1.18 2-1.2 2-0.05 85.4 3.36 Model No.: AT78051 Model No.: AT8-DP11 86.2 3.39 Model No.: AKW1822 4 0.16 60 2.36 79.4 3.13 Convenient when installation is on control panel. Protective cover for DIN 48 size (flexible type) : For KW4M Terminal protective cover: For KW4M screw terminal type (AKW5111 and AKW5112) 47.5 1.87 50 1.97 11.5 0.45 50 1.97 04 0. 0 .2 R R1 R0 Model No.: AKW4823 R5 Model No.: AQM4803 38 1.50 11.5 0.45 30 1.18 11 0.43 4-R0.5 4-R0.02 60.4 60.4 81.4 81.4 11-pin cap: For KW4M 11-pin type (AKW5211 and AKW5212) 4- 4-R R 1. 0. 2 05 Rear terminal socket: For KW4M 11-pin type (AKW5211 and AKW5212) 80 3.15 R2 8 .0 R0 Model No.: AKW8822 88 3.46 92 3.62 0.88 22.3 24.5 0.96 75 2.95 45 + 00.4 1.77 + 0.02 0 6 0.24 Model No.: AKW4822 45 +− 0.6 0 1.77 +− 0.02 0 19 0.75 20 0.79 9 × 8.4 = 75.6 9 × 0.33 = 2.97 1.6 R2 .08 0.06 1.77 +− 0.02 0 2 × × R0 2 4.2 0.17 (R Terminal cover: For all types KW8M 30 8 1.18 8 R2 .0 14.2 R2 0.0 × R0 19 0.56 × 2 × 2 ×R 0.75 2 2 (R ) 110 ± 0.2 4.33 ± 0.01 45 + 0.6 −0 125 4.92 16.5 0.65 92 + 00.4 3.62 + 0.02 0 2.1 (R 4.2 0.17 24 0.94 4.2 0.17 R2 8 .0 R0 1.6 0.06 Mounting frame: For all types KW8M * For fixing 5 70 ± 0.2 2.76 ± 0.01 2 × R2 2 × R0.08 0.20 12.2 ) 0.48 2.1 ) 80 3.15 40 1.57 12.2 0.48 Mounting frame: For KW4M Model No.: AKT8801 Others Screwdriver for terminal socket: For KW7M Backup battery: For KW1M-H, KW1M-R (master unit) and KW2G-H main unit * Packaged with AKW1000, AKW1121 and AKW2020G Model No.: AFP0806 Model No.: AFPG804 Backup battery: For high performance type KW8M (AKW8111H) only * Packaged with the main unit Model No.: AFC8801 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] Dimensions DIMENSIONS Unit: mm in, Tolerance: ± 1.0 ± 0.04 KW2G (Standard type) and KW2G-H (SD memory card type) / AKW2020G Terminal arrangement (for AKW2010G / AKW2020G) Terminal protection cover 60 2.36 Terminal protection cover Connector for current transformer (CT) 25 0.98 14 0.55 35.4 1.39 90 3.54 Connector label Remove when connecting an expansion unit. (69) (2.72) (With a DIN rail) Two hooks Use these hooks when connecting an expansion unit. 65 2.56 60 2.36 16.4 0.65 25 0.98 35.4 1.39 90 3.54 95 3.74 62.2 2.45 49.4 1.94 DIN rail sold separately Input terminal (M3) 23 0.91 (Without cover) Two hooks Use these hooks when connecting an expansion unit. (69) (2.72) (With a DIN rail) 5 0.20 3 0.12 Connector for current transformer (CT)* Output terminal (M3) 14 0.55 Pulse input Phase and wire system Single-phase two-wire system Measured Single-phase voltage three-wire system input Three-phase three-wire system Between terminals (1)−(2) (P1-P0) (1)−(2)−(3) (P1-P0-P2) (1)−(2)−(3) (P1-P0-P2) Terminal Input voltage 100 to 240 V AC (100 to 240 V and after) (Line voltage) 100 to 120 V AC (100 to 120 V and after: 3W) (Phase voltage) 100 to 240 V AC (100 to 240 V 3 and after) (Line voltage) Connector label Remove when connecting an expansion unit. *AKW2110G and AKW2160G only Function + − Terminal type M3 Terminal arrangement (for AKW2152G) Terminal No. (1) (2) (3) (4) Function Terminal type + − + − CH0 CH1 M3 * The “-“ terminals are connected internal. (Between channels: non-isolated) Terminal arrangement (for AKW2182G) Terminal No. (1) (2) (3) (4) Function V/I Voltage/Current COM Common V/I Voltage/Current COM Common CH0 CH1 Terminal type M3 * The “COM” (common) terminals are connected internal. (Between channels: non-isolated) <Wiring diagrams> Single-phase two-wire system * One dedicated CT is required for one load. DIN hook Use these hooks when connecting on the DIN rail 1 2 Main breaker When measuring two circuits, connect the P1 and P2 terminals in series. Eco-POWER METER protection breaker P1 P0 1 P2 2 P. IN − 6 9 + 4 − 8 + 7 10 − 11 E L K CT2 Load protection breaker Main unit L K Load protection CT1 breaker L K CT2 Load protection breaker Expansion unit RS485 (Without cover) L K Load protection CT1 breaker N.C. 3 P. OUT + 5 (AKW2160G) M3 “+ / −” screw RS485 Terminal No. (1) (2) (Expansion unit) AKW2110G / AKW2160G / AKW2152G / AKW2182G AKW2152G and AKW2182G Pulse output Terminal arrangement (for AKW2160G) 5 3 0.20 0.12 DIN hook Use these hooks when connecting on the DIN rail Function Terminal type Measured voltage input P1 and P0 also serve as the terminals M3.5 “+ / −” screw for the operating power supply. No connection P1 P0 P2 NC + − + − + − E The input voltage to each terminal is as follows. 6.9 0.27 USB 2.0 port MiniB (□47.6) (□1.87) 62.2 2.45 M3-7P Fastening torque: 0.5 to 0.6 N•m DIN rail sold separately (□49.4) (□1.94) 95 3.74 SD memory card slot* *SD memory card slot only applies to AKW2020G. Terminal No. (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) Load (4) Load (3) Load (2) Load (1) Load side 50 1.97 16.4 0.65 M3.5-4P Fastening torque: 0.8 to 1.0 N•m Power supply side (Main unit) AKW2010G When an expansion unit is connected Single-phase three-wire system / Three-phase three-wire system Eco-POWER METER protection breaker P1 P0 1 P2 2 9 + L L Main unit 3 4 P. IN − 6 K CT2 N.C. P. OUT + 5 L Load (1) K Load CT1 protection breaker Load side R R1 Main N S 2 breaker T T3 Load (2) Power supply side * Two dedicated CT are required for one load. − 8 + 7 10 − RS485 11 E K Load CT1 protection breaker L K CT2 Expansion unit When an expansion unit is connected Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected] KW SERIES ● Be sure to wire correctly according to the terminal arrangement and wiring diagrams. ● For details, please refer to the Eco-POWER METER user’s manual. Unit: mm in, Tolerance: ± 1.0 ± 0.04 KW1M-R Built-in wireless type (Master unit) AKW1000 Mounting hole dimensions Terminal arrangement 67 ± 0.5 2.64 ± 0.20 0.04 ± 0.02 82 ± 0.5 3.23 ± 0.20 2 × M4 1 ± 0.5 0.04 ± 0.02 50 1.97 47 1.85 25.1 0.99 8 0.31 R1 R0 .04 × 2 No connection RS CS RS232C E N.C. N.C. RS CS 9 10 11 12 13 − 8 + 7 35.4 1.39 90 3.54 82 3.23 RS485 1 2 3 N.C. 4 SD 5 RD 6 SG RS232C * Use a straight cable for RS232C connections. P=8.7 P=0.34 (Slave unit) AKW1131 (54*) (2.13*) (55*) (2.17*) * When installing DIN rail Mounting hole dimensions Terminal arrangement 67 ± 0.5 2.64 ± 0.20 M3 (Fastening torque: 0.5 to 0.6 N•m) ) le ho g in (M 1 ± 0.5 0.04 ± 0.02 2 × ø5 ø0 .2 0 1 ± 0.5 0.04 ± 0.02 (1) (2) (3) (4) (5) (6) R1 R0 (7) (8) (9) M3.5 (10) “+ / −” screw (11) (12) (13) Function + RS485 − E + Pulse output − + Pulse input − * Because the RS485(E) terminal does not have an SG (signal ground) terminal, the ground wire of the shielded cable should not be connected. 50 1.97 47 1.85 25.1 0.99 8 0.31 .04 The input voltage to each terminal is as follows. Phase Between and wire Input voltage terminals system Operating power Single-phase 100 to 240 V AC (100 to 240 V and after) (1)−(2) supply input two-wire (Line voltage) Single-phase 0 to 440 V AC (0 to 440 V and after) (3)−(4) two-wire (Line voltage) Single-phase (3) (4) (5) 0 to 220 V AC (0 to 220 V to: 3W) − − Measured three-wire (Phase voltage) 0 to 440 V AC (0 to 440 V 3 and after) voltage input Three-phase (3) (4) (5) − − three-wire (Line voltage) Three-phase (3) (4) (5) (6) 0 to 254 V AC (0 to 254 V 3N and after) − − − four-wire (Phase voltage) 0.24 1.1 ±0.5 0.04 ± 0.02 71 2.80 60 2.36 58 2.28 35.4 1.39 Terminal 82 3.23 6 Terminal type Terminal No. Terminal type L N P1 M3.5 Measured P0 “+ / −” screw voltage P2 input P3 2 × M4 ou 0.04 ± 0.02 nt 18.2 0.72 Function Operating power supply 82 ± 0.5 3.23 ± 0.20 39.1 1.54 11 11 1 ± 0.5 0.43 0.43 67.8 2.67 M3 (Fastening torque: 0.5 to 0.6 N•m) 75 2.95 P=7.62 67 2.64 P=0.30 90 3.54 Function + − E RS232C RS485 M3.5 (Fastening torque: 0.8 to 1.0 N•m) Connector for current transformer (CT) (7) (8) (9) M3 (10) “+ / −” screw (11) (12) (13) Phase and Between Terminal Input voltage wire system terminals Operating power Single-phase (1) (2) 100 to 240 V AC (100 to 240 V and after) − two-wire (Note) (Line voltage) supply input Operating power supply 100 to 240 V AC 50 / 60 Hz Terminal cover (transparent) (1) (2) (3) (4) (5) (6) The input voltage to each terminal is as follows. 0.24 1.1 ± 0.5 0.04 ± 0.02 71 2.80 60 2.36 58 2.28 6 1 ± 0.5 0.04 ± 0.02 ø5 ø0 .2 0 M3 (Fastening torque: 0.5 to 0.6 N•m) 75 2.95 67 2.64 P=7.62 P=0.30 Terminal type Terminal No. Terminal type L N No connection M3.5 SD “+ / −” screw RS232C RD SG (M ou nt in g 1 ± 0.5 ho le ) Terminal cover (transparent) 67.8 2.67 Function Operating power supply P=8.7 P=0.34 (54*) (2.13*) M3.5 (Fastening torque: 0.8 to 1.0 N•m) (55*) (2.17*) * When installing DIN rail <Wiring diagrams> AKW1131 When measuring load with rated input voltage (100 to 200 V AC system and 400 V AC system) Single-phase two-wire system *One dedicated CT is required. Single-phase three-wire system / Three-phase three-wire system * Two dedicated CT are required. E 9 − 11 + 10 + 12 + Power supply side 0.1 A 30 V DC 1 2 1 2 3 4 P1 Operating power supply 100 to 240 V AC 50 / 60 Hz 5 7 CT1 Measured voltage input CT1 L Three-phase four-wire system * Three dedicated CT are required. Pulse output Pulse input E 9 − 11 + 10 + 12 − 13 Power supply side 1 R1 S2 T3 N4 2 Operating power supply 100 to 240 V AC 50 / 60 Hz 3 4 P1 5 P0 6 P2 P3 Measured voltage input − + 9 10 11 + 12 − 13 CT1 CT2 CT3 K L Direction of CT 1 R R1 NS2 T T3 2 3 Operating power supply 100 to 240 V AC 50 / 60 Hz 4 P1 5 P0 CT1 CT2 6 (Note 2) P2 * Leave CT3 open. Measured voltage input CT1 CT2 K L Direction of CT Notes: 1) Do not wire to (5), (6) terminal. They are connected internal. 2) Do not wire to (6) terminal. They are connected internal. CT1 CT2 CT3 0.1 A 30 V DC Load side − 8 8 E 0.1 A 30 V DC * Leave CT2 and CT3 open. K + 7 − 6 (Note 1) (Note 1) P0 Direction of CT RS485 Pulse output Pulse input RS485 − 13 Power supply side − 8 Load side + 7 Load side RS485 Pulse output Pulse input Dimensions DIMENSIONS Unit: mm in, Tolerance: ± 1.0 ± 0.04 KW1M (Standard type) and KW1M-H (SD memory card type) AKW1110/AKW1111/AKW1121 2 × ø 1 ± 0.5 ø 5 0.04 ± 0.02 0. (Mo 20 u nt in g ho le ) • For mounting hole dimensions, please refer to the KW1M-R "Mounting hole dimensions" on page 25. Terminal arrangement (for AKW1110) 75 2.95 39.1 1.54 67 2.64 1 ± 0.5 11 11 0.04 ± 0.02 0.43 0.43 67.8 2.67 M3 (Fastening torque: 0.5 to 0.6 N•m) 18.2 0.72 90 3.54 82 3.23 6 1.1 ± 0.5 0.24 0.04 ± 0.02 SD memory card slot* 39.1 1.54 Terminal cover (transparent) Connector for current transformer (CT) Terminal No. (1) (2) (3) (4) (5) (6) (7) (Note 1) (8) (9) (10) (Note 2) (11) (12) (13) (Note 1) (14) (Note 1) Terminal cover (transparent) AKW1110/AKW1121 Connector for current transformer (CT) P1 P0 P2 Terminal type Measured voltage input No connection + – E + – M3 “+ / −” screw RS485 Pulse output No connection Notes: 1) The (7), (13) and (14) terminals are connected internal to analog input terminal. Cannot use extending wiring. 2) Because the RS485(E) terminal does not have an SG (signal ground) terminal, the ground wire of the shielded cable should not be connected. The input voltage to each terminal is as follows. (for AKW1110) 1 ± 0.5 11 0.43 67.8 0.04 ± 0.02 2.67 18.2 0.72 *SD memory card slot only applies to SD memory card type KW1M-H. Function Operating power supply No connection L N Terminal Phase and wire system Between terminals (1)−(2) Operating power supply input Single-phase two-wire Single-phase two-wire (4)−(5) Measured voltage input Single-phase three-wire (4)−(5)−(6) Three-phase three-wire (4)−(5)−(6) AKW1111 <Wiring diagrams> Input voltage 100 to 240 V AC (100 to 240 V and after) (Line voltage) 0 to 220 V AC (0 to 220 V and after) (Line voltage) 0 to 110 V AC (0 to 110 V to: 3W) (Phase voltage) 0 to 220 V AC (0 to 220 V 3 and after) (Line voltage) AKW1110 When measuring load with rated input voltage (100 to 200 V AC system) Single-phase three-wire system / Three-phase three-wire system Single-phase two-wire system *One dedicated CT is required. * Two dedicated CT are required. 13 14 2 3 4 5 6 CT1 + 8 − 9 E 10 + 11 − 12 13 14 1 2 3 4 5 6 7 (Note) 0.1 A 30 V DC 7 N.C. (Note) (Note) (Note) P1 P0 Operating power supply Measured 100 to 240 V AC voltage input 50 / 60 Hz 1 2 * Leave CT2 and CT3 open. CT1 L K Direction of CT Power supply side Power supply side (Note) (Note) 0.1 A 30 V DC 1 P.OUT RS485 − 12 + 11 Load side E 10 − 9 Note: Do not wire to (3), (6), (7), (13), (14) terminal. They are connected internal. (Note) CT1 CT2 N.C. (Note) (Note) P1 P0 P2 Operating power supply Measured 100 to 240 V AC voltage input 50 / 60 Hz RR1 NS2 TT3 * Leave CT3 open. CT1 Load side RS485 Pulse output + 8 CT2 L K Direction of CT Note: Do not wire to (3), (7), (13), (14) terminal. They are connected internal. AKW1111 When measuring load with rated input voltage (100 to 200 V AC system and 400 V AC system) Single-phase two-wire system *One dedicated CT is required. Single-phase three-wire system / Three-phase three-wire system * Two dedicated CT are required. + Power supply side 1 1 2 2 3 4 P1 7 CT1 0.1 A 30 V DC Operating power supply 100 to 240 V AC 50 / 60 Hz 5 CT1 L Direction of CT + 12 − 13 0.1 A 30 V DC Power supply side 1 R1 S2 T3 N4 2 3 Operating power supply 100 to 240 V AC 50 / 60 Hz 4 P1 P0 CT2 CT2 CT3 6 5 P2 P3 Measured voltage input CT1 CT2 CT3 K L Load side − 11 + 10 9 − + 10 11 − + 12 13 1 RR1 NS2 TT3 2 3 Operating power supply 100 to 240 V AC 50 / 60 Hz 4 P1 5 P0 CT1 CT2 6 (Note) P2 Measured voltage input * Leave CT3 open. CT1 CT2 L K Direction of CT Terminal arrangement (for AKW1111) Pulse output Pulse input E 9 8 Note: Do not wire to (6) terminal. They are connected internal. Three-phase four-wire system * Three dedicated CT are required. − 8 E 0.1 A 30 V DC * Leave CT2 and CT3 open. Note: Do not wire to (5), (6) terminal. They are connected internal. RS485 − 6 (Note) (Note) P0 Measured voltage input K + 7 Pulse output Pulse input RS485 − 13 + 12 Power supply side − 11 + 10 Load side E 9 − 8 Load side RS485 Pulse output Pulse input + 7 Direction of CT Terminal No. (1) (2) (3) (4) (5) (6) L N P1 P0 P2 P3 (7) (8) (9) (10) (11) (12) (13) + E + + - Function Terminal type Operating power supply Measured voltage input M3.5 “+ / −” screw RS485 Pulse output M3 “+ / −” screw Pulse input * Because the RS485(E) terminal does not have an SG (signal ground) terminal, the ground wire of the shielded cable should not be connected. The input voltage to each terminal is as follows. Terminal Operating power supply input Phase and wire system Between terminals Input voltage Single-phase two-wire (1)−(2) 100 to 240 V AC (100 to 240 V and after) (Line voltage) (3)−(4) (3)−(4)−(5) 0 to 440 V AC (0 to 440 V and after) (Line voltage) 0 to 220 V AC (0 to 220 V to: 3W) (Phase voltage) Single-phase two-wire Measured voltage Single-phase three-wire KW SERIES AKW1121 When measuring load with rated input voltage (100 to 200 V AC system and 400 V AC system) Single-phase two-wire system Single-phase three-wire system / Three-phase three-wire system * Two dedicated CT are required. 1 2 − 12 + 11 E 10 − 14 + 13 Power supply side 3 4 N.C. 5 6 1 2 − 9 1 2 E 10 + 11 − 12 − 14 + 13 CT1 CT2 0.1 A 30 V DC 7 (Note) (Note) P1 P0 Measured voltage input Operating power supply 100 to 240 V AC 50 / 60 Hz + 8 CT1 0.1 A 30 V DC Power supply side − 9 * Leave CT2 and CT3 open. Load side + 8 P.OUT Pulse input RS485 RS485 Pulse output Pulse input CT1 L K Direction of CT 3 N.C. 4 5 6 7 (Note) P1 P0 P2 Operating power supply Measured 100 to 240 V AC voltage input 50 / 60 Hz R R1 * Leave CT3 open. CT1 NS2 TT 3 CT2 L K Note: Do not wire to (7) terminal. They are connected internal. Note: Do not wire to (6), (7) terminal. They are connected internal. Load side *One dedicated CT is required. Direction of CT Terminal arrangement (for AKW1121) No. (1) (2) (3) (4) (5) (6) (7) Three-phase four-wire system * Three dedicated CT are required. − 9 1 2 E 10 − 12 + 11 Pulse input − 14 + 13 0.1 A 30 V DC 3 4 N.C. 5 CT1 CT2 CT3 6 7 Power supply side P1 P0 P2 P3 Operating power supply Measured 100 to 240 V AC voltage input CT1 50 / 60 Hz R1 CT2 S2 CT3 T3 N4 K L 5.5 0.22 (□44.5) (□1.75) V Pulse input Terminal type 11-pin type Screw terminal type 1 1, R, R RS485 (–) 2 2, N, S CT1 (k)/IN 3 3, T, T CT1 (ℓ), CT2 (ℓ) 4 RS485 (+) CT2 (k) 5 RS485 (–) 0V M3.5 6 Pulse output (+) Pulse output (+) “+ / −” screw 7 Pulse output (–) Pulse output (–) 8 CT1 (k)/IN 1, R, R 9 CT1 (ℓ), CT2 (ℓ) 2, N, S 10 CT2 (k) 3, T, T 11 0V RS485 (+) kW/kWh A 14.5 0.57 EcoPOWER METER Panasonic MODE Lock 1 2 OP CT1 3 4 CT2 CHARGE M3 “+ / −” screw Pulse output No. MODE Lock 1 2 OP CT1 3 4 CT2 MODE SET TIME COUNT V CHARGE (□44.5) (□1.75) EcoPOWER METER TIME RS485 Terminal arrangement 11-pin type (AKW5211/AKW5212) 5.5 0.22 COUNT Terminal type Unit: mm in, Tolerance: ± 1.0 ± 0.04 87.5 3.44 SET Function Terminal Phase and wire system Between terminals Input voltage Operating power supply input Single-phase two-wire (1)−(2) 100 to 240 V AC (100 to 240 V and after) (Line voltage) Single-phase two-wire (4)−(5) 0 to 440 V AC (0 to 440 V and after) (Line voltage) Single-phase three-wire (4)−(5)−(6) 0 to 220 V AC (0 to 220 V to: 3W) (Phase voltage) Measured voltage input Three-phase three-wire (4)−(5)−(6) 0 to 440 V AC (0 to 440 V 3 and after) (Line voltage) Three-phase four-wire (4)−(5)−(6)−(7) 0 to 254 V AC (0 to 254 V 3N and after) (Phase voltage) Direction of CT Screw terminal type (AKW5111/AKW5112) MODE + – E + – + – The input voltage to each terminal is as follows. KW4M Panasonic No. (8) (9) (10) (11) (12) (13) (14) * Because the RS485(E) terminal does not have an SG (signal ground) terminal, the ground wire of the shielded cable should not be connected. Load side P.OUT RS485 + 8 Function Terminal type L Operating N power supply No connection M3 P1 “+ / −” screw P0 Measured P2 voltage input P3 kW/kWh A KW4M KW4M □48 □1.89 81.9 3.22 □48 □1.89 73 2.87 Note: A DIN rail terminal socket (ATC180041) should be used for 11-pin type KW4M Eco-POWER METER. Unit: mm in, Tolerance: ± 1.0 ± 0.04 KW7M M3 Phoenix terminal Terminal arrangement A V kW No. 1 2 3 4 5 6 7 8 9 DIN rail KW M kWh Lock T/R MODE M2 Phoenix terminal OUT 75 2.95 CHARGE ITEM SHIFT SET Eco-POWER METER 97 3.82 22.5 0.89 (4) (0.16) 100 3.94 8.1 0.32 CT1 CT2 11 0.43 AKW8111/AKW8111H Screw-type bracket (included) 24.1 0.95 MODE OPTION SET 48 1.89 SHIFT Terminal cover (sold separately) 91 3.58 106.2 4.18 96 3.78 96 3.78 Gasket (included) ITEM START STOP 48 1.89 11.5 0.45 98.5 3.88 104.5 4.11* * With the terminal M3 + / – cover attached Fastening torque: 0.6 to 1.0 N•m Terminal type Phoenix terminal M3 “−” screw Phoenix terminal M2 “−” screw * Because the RS485(E) terminal does not have an SG (signal ground) terminal, the ground wire of the shielded cable should not be connected. KW8M, KW8M (High performance type) and KW8M (1 A / 5 A CT input type) AKW8115 Function 1, R, R 2, N, S 3, T, T No connection Pulse output (+) Pulse output (–) RS485 (+) RS485 (–) RS485 (E) Unit: mm in, Tolerance: ± 1.0 ± 0.04 Terminal arrangement No. Function 1 No connection 2 Operating power supply 3 4 Pulse input 5 6 Pulse output 7 8 RS485 9 10 L N + – + – + – E No. 11 12 13 14 15 16 17 18 19 20 Function Terminal type P1 P0 Measured voltage input P2 P3 CT1 (+) M3 Measured CT input “+ / −” screw CT1 (−) for AKW8111 and CT2 (+) AKW8111H CT2 (−) Measured current CT3 (+) input (for AKW8115) CT3 (−) ( ) * Because the RS485(E) terminal does not have an SG (signal ground) terminal, the ground wire of the shielded cable should not be connected. CE Marking KW SERIES CE MARKING ■ Acquisition of CE marking When using in the application conforming to EN61010-1/IEC61010-1, make sure to satisfy the following conditions. [Environmental conditions] • Overvoltage category II, Pollution degree 2 • Indoor use • An ambient temperature of -10 to 50°C 14 to 122°F • An ambient non-condensing humidity of 35 to 85%RH (at 20°C 68°F) • Altitude of 2,000 m 6,562 ft or less [Mount the product in a place with] • A minimum of dust, and an absence of corrosive gases • No flammable, explosive gasses • Few mechanical vibrations or shocks • No exposure to direct sunlight • No large capacity electromagnetic switches or cables through which large current is flowing ■ Applicable standard Safety EN61010-1 standard EMI Radiation interference field strength EN61326-1 Noise terminal voltage Static discharge immunity RF electromagnetic field immunity EFT/B immunity EMC Surge immunity EMS Conductivity noise immunity EN61326-1 Power frequency magnetic field immunity Voltage dip / Instantaneous stop / Voltage fluctuation immunity Others CISPR11 class A CISPR11 class A EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 KW SERIES ENERGY EFFICIENCY SUPPORT EQUIPMENT LINEUP Visualize Air Consumption Data collection and storage Monitoring by LAN (Ethernet) DLL KS1 Signal Converter Air Flow Monitor EWA1 • Ultrasonic type resistant to oil mist • No need to use dedicated filters • Pipe size: 25A (1B) to 200A (8B) (Data Logger Light) • Collecting and storing power, pulse and analog data of Eco-POWER METER • Provided with a USB port and an SD/SDHC memory card slot • Equipped with an AC/DC power supply • Provided with a RS232C/RS485 communication port [MEWTOCOL / MODBUS (RTU)] • Converting RS232C/RS485 power data for communications by LAN For cases where wired connection is difficult KR20 Wireless Unit Wireless Sensor EWR1 Master unit Slave unit • Wireless communications of RS232C/RS485 power data • 2.4 GHz band wireless communications • Compliant with wireless standards of Europe and Japan • Wireless communications of illuminance data/temperature and humidity data • Radially connect slave units with the master unit at the center • 2.4 GHz band wireless communications * Please contact our sales offices for more information about which areas this product can be used. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]