Transient and Steady State Responses
When the desired input signal (r) changes suddenly, the system will react in two
phases, as shown in Figure A-3. The initial reaction to a change in the input
signal is called the transient response. The second part of the reaction is known as
the steady state response. Once the input signal (r) has remained constant for
some time, and the error between the input and output signals has stabilized, the
system is said to be in steady state. The transition from transient to steady state is
not a cleanly defined break.
Figure A-3: Transient and Steady States
This constant error, known as the steady state error, should be reduced as much as
possible by the control system.
Increasing the amplitude of the controller output signal (that is, increasing the
controller gain) can reduce the steady state error and enable a more rapid
approach to the steady state value. The greater the controller gain, the faster the
system reacts.
However, excessive gain may lead to a phenomenon called overshoot—a rise in
the controlled value to a point above the desired value, followed by a drop below
the desired value, repeated several times before stabilization. This, in effect,
causes the actual value to oscillate around the desired value. Further increase of
the controller gain may lead to instability of the entire system— that is,
uncontrollable oscillation.
A control system is damped when it reaches steady state without overshoot. A
critically damped response is the fastest approach to steady state without
overshooting; an overdamped response is a slow approach to steady state.
Figure A-4 shows different transient responses.