PID MODULE MAIN FUNCTIONS Action after Power Is Restored When the power is restored, every bit of the operation parameter excluding the program hold bit stored in the data register is maintained. If the power is failed and restored while the PID module performs the program control, the PID module starts its operation in accordance with the original PID module status before the power failure as shown in the table below. Program End Action PID Module Status before the Power Failure Program Program Control is Program Control is Control is suspended (Hold) Terminated. Performing. Standby Status (*1) Terminate Program Control Continue Program Control (Repeat) The program control is started from the Step 0. The program control is continued. *2, *3 Standby status is maintained. Hold Program Control The program hold is canceled, and the program control is continued. *2, *3 The program hold is maintained. Fixed value control is performed with the set point (SP) at the time that the power is turned off. *1: The PID module is in standby status when the control enable bit is on but the program control bit is off. While in standby status, the PID module performs no control. *2: While the program control is running, the PID module saves the program control status every 6 minutes after the program control is started (after the program control bit is turned on). The program control status is also saved at the start of each step. If the power to the PID module is turned off while the program control is running, the PID module resumes the program control from the latest saved point. Step Number 0 1 2 3 10 min 15 min 3 min 6 min 4 Step Time (1) Program Control Status Saved Point Elapsed Time from Program Control Start 0 min (2) 6 min 12 min 18 min 10 min (3) 25 min 24 min 30 min 34 min 28 min For example, if the power to the PID module is turned off in 7 minutes after the program control is started at step 0, the PID module resumes the program control at the status (1) when the power is restored. If the power to the PID module is turned off in 4 minutes after the program control enters step 1, the PID module resumes the program control at the status (2) when the power is restored. If the power to the PID module is turned off in 2 minutes after the program control enters step 2, the PID module resumes the program control at the status (3), which is the start of step 2, when the power is restored. *3: To restart the program control from the start of step 0, turn off and on the program control bit (operation parameter Bit3). 4-12 FC5A MicroSmart PID Module User’s Manual FC9Y-B1283