Architectures (continued) Modicon Premium automation platform Hot Standby system Unity Pro software Architectures (continued) SCADA architecture on Modbus and shared I/O on Ethernet Modbus/TCP 1 As in the typical architecture on page 4/54, the Premium Hot Standby system I/O are shared on an Ethernet Modbus/TCP network (with a bus topology as in the example below). However, the SCADA interface is connected to the standby system via a Modbus serial link. The Ethernet Modbus/TCP network modules no. 4 - M are configured as “monitored” so that they trigger the Hot Standby changeover in the event of a failure (of the Ethernet module or the electrical connection and its switch) (see page 4/54). 2 SCADA Vijeo Citect Monitor Pro 31 31 34 Modbus 3 Modbus master 33 Primary Premium 2 3 4-M Standby Premium 8 2 3 4 5 6 7 8 9 8 4-M 1 Redundant components: 1 Non-expandable rack with 6, 8 or 12 positions TSX RKY pp (single-rack configuration) or expandable with 4, 6, 8 or 12 positions TSX RKY ppEX (multi-rack configuration) 2 Power supply module TSX PSY pppM 3 Hot Standby processor TSX H57 24M/44M 4-M “Monitored” Ethernet Modbus/TCP network module TSX ETY 4103/5103 (version u sv 4.0) 8 Serial link communication module TSX SCY 21601 on which the integrated channel cannot be used in this type of architecture 9 Isolated RS 485 PCMCIA card TSX SCP 114 used in Modbus slave protocol Shared components on the Ethernet Modbus/TCP network: 15 Modicon M340 automation platform with processor with integrated Ethernet port BMXP34 2020/2030 16 Modicon STB modular distributed I/O with network interface module STB NIP 2212 17 Altivar 61/71 variable speed drive with communication card VW3 A3 310 18 Optimum Modicon OTB distributed I/O, with interface module OTB 1E0 DM9LP 19 Magelis XBT GT graphic display terminal with embedded Ethernet port XBT GT pp30/40 Other possible shared components: (see page 4/54) Ethernet cabling components: 10 ConneXium unmanaged switch with 5 ports 10BASE-T/100BASE-TX 499 NES 251 00 11 CPU Sync link, copper crossover cable 490 NTC 000 ppp 12 Copper straight-through cable 490 NTW 000 ppp 13 Copper crossover cable 490 NTC 000 ppp 9 Slave 9 Slave 11 CPU Sync link 12 13 Ethernet Modbus/TCP 10 10 19 17 16 15 Modicon M340 18 Modicon STB 4/56 Modicon OTB SCADA supervision system A failure triggers the changeover so that the Standby PLC becomes the Primary PLC and automatically switches the Modbus addresses, the address of the new Primary PLC becoming “n” and that of the old Primary PLC becoming “n+1”. 10 Description: page 4/53 Altivar 61 Magelis XBT GT In this type of architecture, redundancy of the SCADA station, based on the Vijeo Citect or Monitor Pro supervision software, is provided by a Modbus serial link on which the SCADA station is master. The Primary and Standby Premium PLCs via their TSX SCY 21601 communication module equipped with the TSX SCP 114 RS 485 PCMCIA card have the slave addresses “n” and n+1 respectively. Modbus cabling components: 31 Passive T-junction box, connection on screw terminals with line terminator TSX SCA 50 33 Drop cable for PCMCIA card with flying leads at at one end TSX SCP CM 4030 (3 m long) 34 RS 485 double shielded twisted pair trunk cable TSX CSA 100/200/500 (100, 200 or 500 m long) Presentation: page 4/52 12 12 Functions: pages 4/58 ... References: pages 4/60 ...