Download My Document - LMI Technologies
Transcript
Field Type Offset Description 0 – Ready 1 – Running role 32s 48 Sensor role 0 – Main 1 – Buddy buddyId 32s 52 Serial number of paired device (main or buddy). 0 if unpaired. Get States The Get System Info command a list of useful system states. Command Field Type Offset Description length 32u 0 Command size including this field, in bytes. id 16u 4 Command identifier (0x4525) Field Type Offset Description length 32u 0 Reply size including this field, in bytes. id 16u 4 Reply identifier (0x4525). status 32s 6 Reply status. count 32u 10 Number of state variables. sensorState 32s 14 Sensor state Reply -1 – Conflict 0 – Ready 1 – Running loginState 32s 18 Device login state 0 – No user 1 – Administrator 2 – Technician alignmentReference 32s 22 Alignment reference 0 – Fixed 1 – Dynamic alignmentState 32s 26 Alignment state 0 – Unaligned 1 – Aligned recordingEnabled 32s 30 Whether or not recording is enabled 0 – Disabled 1 – Enabled playbackSource 32s 34 Playback source 0 – Live data Gocator 2300 & 2880 Series Protocols • Gocator Protocol • 247
Related documents
Manual Gocator 3100 Series
Gocator 1300 Series User Manual - Downloads
Gocator 3100 Series User Manual - Downloads
Gocator 3100 Series
Gocator 2000 & 2300 Series
Gocator 2000 & 2300 Series
MAPCOMP Map Specification Language (R20)
HexSight 5.0 Quick Start Guide - Downloads
Using Gocator laser profiling sensor with HALCON
2-CHANNEL MODULE of LOGIC or COUNTER INPUTS SM3 TYPE
Quickstart Gocator 2000 Series
Quick Start Guide - Downloads