Download DataSuite User Guide
Transcript
13.4. Unit Serial Number and Comment Every MicroLogPRO II data logger unit is embedded with a unique serial number. The data logger only can be loaded with a descriptive comment to identify its task and location. You may add or edit the logger comment via the DataSuite software. Every time data is transferred to the computer it is labeled both with the logger’s serial number and comment and is displayed in the graph or data table view. The unit serial number is also marked on a sticker on the back of the product. 13.5. Power Supply The MicroLogPRO II data loggers run from one internal, replaceable 2/3 AA 3.6 V lithium battery. Depending on the logger configuration and operating conditions, from a new battery, the data logger can run for up to 2 years. Note: When connected to the PC via USB, the logger will draw its power via the USB port and not via the internal battery. 13.5.1. Battery Level Indication The MicroLogPRO II battery level indication is viewed as follows: On the logger LCD * In the DataSuite logger Setup dialog and logger icon tooltip in Map View * EC800/EC850 Rev B, firmware v2.00 or higher only Battery Level on Logger LCD 4-segment battery icon is displayed on the logger LCD (it is always displayed) The definition of each segment is: 3 segments: 100% 2 segments: 50 > 99% 1 segment: 25 > 49% 0 segments: 0 > 24% Measurement of Battery Voltage The battery voltage is measured as follows: Each time the device is removed from the USB and is updated in the software upon reconnection to PC. When the logger is in Run mode and not connected to the USB, it is measured every hour and recorded to the logger memory. When reconnected to USB, DataSuite takes the last battery reading recorded to memory. 132