Download ERZ 2000 Operating Instructions
Transcript
ANNEX ............................................................................................................................................................................................................... Temperature correction for orifice and pipe GA10 Substance orifice GA11 Substance pipe Coefficients Options A B off - - Linear - - GOST - - Steel I 12,60 0,0043 Steel II3 12,42 0,0034 Steel III 12,05 0,0035 Steel IV 10,52 0,0031 Steel V 17,00 0,0038 Steel VI 16,30 0,0116 Bronze SnBz4 17,01 0,0040 Copper E-Cu 16,13 0.0038 Gunmetal Rg9 16,13 0,0038 Brass Ms63 17,52 0,0089 Nickel 14,08 0,0028 Hastelloy C 10,87 0,0033 179 off The relevant temperature correction is deactivated. linear The correction factors GA03 T-crr fact orifice and GA04 T-crr fact pipe are calculated using the linear heat expansion coefficients GA05 Lin.expanse orifice and GA06 Lin.expanse pipe. T Ber . fakt 1 A.lin (Temp 20) Material selection The correction factors GA03 T-crr fact orifice and GA04 T-crr fact pipe are calculated using an approximation equation and the coefficients A and B. T Ber. fakt 1 ( A (Temp 20) B (Temp 20) 2 ) 106 Coefficients are assigned automatically when a material is selected. The permitted temperature range for the materials listed extends from -200°C to 600°C, with the exception of copper, nickel and brass, which have an upper limit of 500°C. ...............................................................................................................................................................................................................