Download Reference Manual - Krypto Security
Transcript
Special Opening: A Special Opening Reporting Code will be transmitted if the Partition(s) is disarmed using any of the following methods: • Disarming using the Maintenance Code • Disarming via the DLS Software • Disarming via keyswitch [345] - Maintenance Alarm Reporting Codes Battery Trouble Alarm: the panel will transmit a Battery Trouble Alarm Reporting Code when the backup battery drops below 11.5 VDC. AC Failure Trouble Alarm: the panel will transmit an AC Failure Trouble Alarm Reporting Code when the AC to the panel is lost and the AC Failure Communication Delay timer expires. Bell Circuit Trouble Alarm: a Bell Circuit Trouble Alarm Reporting Code will be transmitted immediately if an open condition is measured on the Bell Output of the main panel. Fire Trouble Alarm: a Fire Trouble Alarm Reporting Code will be transmitted immediately when an open condition is measured on any Fire type zone. Auxiliary Power Supply Trouble Alarm: the Auxiliary Power Supply Trouble Alarm Reporting Code will be transmitted if the AUX output is shorted. TLM Trouble: a TLM Trouble Reporting Code can only be transmitted if an alternate communicator is being used. The panel will only transmit the signal after the time programmed for the TLM Trouble Delay. General System Trouble: a General System Trouble Reporting Code will be transmitted if the panel detects any of the following: • AC Power Failure • Low Battery • AUX Output Trouble • Output #1 on the PC5200/PC5204 Power Supply/Output Module. • T-Link Troubles General System Supervisory Trouble: a General System Supervisory Trouble Reporting Code will be transmitted if any module goes missing from the Keybus. If the module is a zone expander the panel will also transmit the Zone Expander Supervisory Alarm Trouble Reporting Code. [346] - Maintenance Alarm Reporting Codes Battery Trouble Restoral: the Battery Trouble Restoral Reporting Code will not be transmitted until the battery has been charged over 12.5 VDC. AC Failure Trouble Restoral: the AC Failure Trouble Restoral Reporting Code will be transmitted once AC power has been restored for the amount of time programmed for AC Failure Communication delays. Bell Circuit Trouble Restoral: the Bell Circuit Trouble Restoral Reporting Code will be transmitted as soon as the open condition on the bell output is corrected. Fire Trouble Restoral: the Fire Trouble Restoral Reporting Code will be transmitted when the correct resistance value is measured on any Fire type zone. Auxiliary Power Supply Trouble Restoral: the panel constantly checks the AUX output, when the excessive current draw is removed the panel will reset the output and transmit an Auxiliary Power Supply Trouble Restoral Reporting Code. TLM Restoral: the TLM Restoral Reporting Code will be transmitted immediately after the trouble is restored. General System Trouble Restoral: a General System Trouble Restoral Reporting Code will be transmitted when the panel detects none of the following: • AC Power Failure • Low Battery • AUX Output Trouble zone. A different reporting code can be programmed for each zone for identification. [334]-[337] - Tamper Reporting Codes, Zones 1 to 64 The Zone Tamper Restoral Reporting Code will be transmitted immediately when the tamper condition is restored. [338] - Miscellaneous Tamper Reporting Codes General System Tamper: a General System Tamper Reporting Code will be transmitted when the tamper zone on any module is violated. General System Tamper Restoral: the General System Tamper Restoral Reporting Code will be transmitted when the tamper zone on the module is restored. Keypad Lockout: the panel will transmit the Keypad Lockout Reporting Code if the lockout is activated. [339]-[340] - Closing (Arming) Reporting Codes, Zones 1-32 The panel will transmit a Closing Reporting Code to indicate a Partition(s) is armed. A different reporting code can be transmitted for each User Code, Partition Master Code and System Master Code to identify who armed the partition(s). [341] - Miscellaneous Closing (Arming) Reporting Codes Closing by Duress Code 33/34: a closing by Duress Code Reporting Code will be transmitted in addition to the Duress reporting code if a Partition(s) is armed using a Duress Code Closing by Master or Supervisory Code: the panel will transmit a Closing Reporting Code to indicate a Partition(s) is armed. A different reporting code can be transmitted for each User Code, Supervisory Code and System Master Code to identify who armed the Partition(s). Partial Closing: a Partial Closing Reporting Code will be transmitted if a Partition is armed with zones manually bypassed. The code will also be transmitted if a Partition Auto Arms with zone(s) in violation. Special Closing: a Special Closing Reporting Code will be transmitted if the Partition(s) is armed using any of the following methods: • Quick Arm • Auto Arm • Arming via the DLS Software • Arming via Keyswitch • Away Function Key Arming • Arming with the Maintenance Code • Stay Function Key arming Late to Close: a Late to Close Reporting Code will be transmitted if a partition isn't armed before the Auto-arm start time when the late to close option, (Section 017, option 5) is enabled. [342]-[343] - Opening (Disarming) Reporting Codes Access Codes 1 to 32 The panel will transmit an Opening Reporting Code to indicate partition(s) is disarmed. A different reporting code can be transmitted for each user code, partition master code and system master code to identify who armed the partition(s). [344] - Miscellaneous Opening (Disarming) Reporting Codes Opening by Duress Code 33/34: This Reporting Code will be transmitted in addition to the duress reporting code if a Partition(s) is disarmed using a Duress Code Opening by Master or Supervisory Code: The panel will transmit this reporting code to indicate a Partition(s) is armed. A different reporting code can be transmitted for each User Code, Supervisory Code and System Master Code to identify who armed the Partition(s). Auto Arm Cancellation: This reporting code is transmitted when the Auto Arming sequence is canceled or Postponed 37