Chapter 4 4.1 Multi-Drop Link Mode Control Procedure Multi-Drop Link Mode 4.1.1. Controlling multi-drop link mode Multi-drop link mode can control up to thirty-one BL series units through a host computer. Since the complex communication (RS-485 communication) between each BL series unit and the N-400 is controlled by the N-400, the host computer controls the communication with the N-400 only, and consequently can be operated with a simple program. (The ID number assigned to the header of the transmitted data allows you to identify the BL series unit that sent the data.) Therefore, multi-drop link mode provides a system configuration that allows use of a simpler program on the host computer. The procedures for controlling the N-400 through a host computer are classified into the following three methods: 4 • Data communication: Used to send bar code data read by the BL series to the host computer. • Command communication to the BL series: Used to send commands to the BL series. • Command communication to the N-400: Used to control the N-400 directly or change the settings of the N-400. * All of the above communication is performed using ASCII codes. Details on these control methods are described on the following pages. 58