Download Manual - Amazon Web Services

Transcript
File Mode
Start: starting condition of the acquisition
-Manual: by the key “Force the triggering”
- Triggering: on combination od analogical and logical channels, see chapter Triggering
- Waiting: after a period or a precise date and hour
- Automatic: immediate; automatic stop when the block is full
Pre triggering: definition of the position of the starting trigger in the acquisition
- Acquisition pre triggering and post triggering (before or after the start), see chapter Memory Mode
Caliber channels: selection of the channels to compare with the caliber (by pressing on “caliber channels”; access to the definition of the caliber)
“Impossible” is displayed when the possibilities of back up are not possible anymore: reduce the sampling speed or the number of channels
See chapter File Mode to know the limits of the recording on a file.
Rest of acquisition: actions after the end of the acquisition
- Back up in a file: back up the acquisition in a file if the Real Time back up is not validated (or is impossible)
- Sending an email: this option will appear if you added a mail address before in “additional options” in the Config. Menu;
- Drawing: drawing of the simultaneous acquisition in memory
- Stop: no action
- Rearmament: launch the drawing again; waiting for the starting condition again
- Change setup: loading of a configuration and waiting of the triggering
9.2. Creation of the caliber
Set the parameter “caliber channels” in the page “triggering” selecting a channel and a logical operator (AND or OR)
Do a normal acquisition or observe a file previously saved by the “memory output” function.
The appliance displays the current caliber, shown with 2 curves (one min, and one max) aroung the selected channel as reference for the caliber.
Page 9.2