Download AG-Star User Manual
Transcript
B.3 FRESET Clear Selected Data from NVM and Reset The OEMStar freset command is extended to include AG-Star features. An additional target field, userdata (value = 10), resets only the AG-Star user data NVM, thereby resetting all parameters indicated in this document as “Stored in NVM” to factory defaults. Issuing the freset command with the “target” field set to standard, resets the userdata NVM as well as OEMStar parameters as indicated in the OEMStar Firmware Reference Manual. If you issue the FRESET command without any parameters, it is the same as issuing a FRESET STANDARD command. Field Type Field ASCII Value Binary Value 1 FRESET header - - 2 target See Table 11, FRESET Target on page 53 Description Binary Format Binary Bytes Binary Offset This field contains the command name or the message header depending on whether the command is abbreviated ASCII, ASCII or binary. H 0 Data to be reset by the receiver 4 H Enum Table 11: FRESET Target Binary ASCII Description 0 STANDARD Resets commands, ephemeris, and almanac (default). 1 COMMAND Resets the stored commands (saved configuration) 2 GPSALMANAC Resets the stored GPS almanac 3 GPSEPHEM Resets the stored GPS ephemeris 4 GLOEPHEM Resets the stored GLONASS ephemeris 5 MODEL Resets the currently selected model 10 USERDATA Reset AG-Star only commands 11 CLKCALIBRATION Resets the parameters entered using the CLOCKCALIBRATE command 20 SBASALMANAC Resets the stored SBAS almanac 21 LAST_POSITION Resets the position using the last stored position 31 GLOALMANAC Resets the stored GLONASS almanac AG-Star User Manual Rev 4 53