Download Release 1.3 - Instrumentation Projects

Transcript
®
LinMot ASCII protocol
Reference table: position increment
LinMot ®
System error codes (syserr)
Code
Description
‘2’
Supply voltage too low for power part.
‘3’
Supply voltage too high for power part.
‘4’
Supply voltage too low for signal part.
‘5’
Supply voltage too high for signal part.
‘6’
Servo controller overheated.
Motor fault codes (driveerr)
Code
Description
‘1’
Motor overloaded.
‘2’
Motor overheated.
‘3’
A following error has occurred.
‘4’
The motor slider is missing.
‘6’
An error has occurred during initialization.
‘7’
Wrong motor type configured or motor defective.
‘8’
No motion profile for the motor, or a motion profile selected is incompatible with
the motor type.
8.8 Reference table: position increment
The following table lists the values signaled back when the PI command is
used. They may, however, alter with a future ASCII protocol version. Whenever possible therefore, the position increment should be queried with the PI
command.
Motor type
Increment
LinMot®
19.53125 µm
Stepper
1/8 Step
Solenoid
23.438mA
8.9 Reference table: speed increment
The table below lists the values signaled back when the VI command is given.
They may, however, alter with a future ASCII protocol version. Whenever
possible, therefore, the speed increment should be queried with the VI command.
User Manual Release 1.3
Motor type
Increment
LinMot®
190.735 µm/s
Stepper
0.081469 Steps/s
Solenoid
0
147