1.5 Power Supply
Specifications
300 watt redundant power supply
Output rating: 300 W maximum
Input voltage: 90/180 ~ 132/264 VAC @ 47 ~ 63 Hz
Output voltage: +5 V @ 30 A, +12 V @ 12 A, -5 V @ 0.5 A, -12 V @ 1 A
Min. load: +5 V @ 2 A, +12 V @ 1 A
MTBF: 100 K hours
Safety: UL/CSA/TUV/CE
EMI: FCC Part 15 Class B, CISPR 22 Class B, VCCI Class 2
400 watt single power supply
Output rating: 400 W maximum
Input voltage: 100/200 ~ 130/260 VAC @ 47 ~ 63 Hz
Output voltage: +5 V @ 40 A, +12 V @ 20 A, -5 V @ 0.5 A, -12 V @ 1 A
Min. load: +5 V @ 3 A, +12 V @ 0.5 A
MTBF: 150 K hours
Safety: UL 1950, CSA E.B. 1420C
EMI: FCC Part 15, CISPR 22 Class A
Installation Notes
The IPC-623 is designed to permit the connection of the earthed conductor of the DC supply circuit to
the earthing conductor of the IPC-623's chassis.
If this connection is made, make sure that:
1. The IPC-623 is connected directly to the DC supply system earthing electrode conductor, or to a
bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode conductor is connected.
2. The IPC-623 is located not only in the same immediate area (such as adjacent cabinets) as any other
equipment that has a connection between the earthed conductor of the same DC supply circuit.and
the earthing conductor, but also in the same immediate area as the point of earthing of the DC
system. The DC system must not be earthed elsewhere.
3. The DC supply source is located within the same premises as the IPC-623.
4. No switching or disconnecting device is installed in the earthed circuit conductor between the DC
source and the point of connection of the earthing electrode conductor.
Warning:
Due to the high wattage of the IPC-623, users must not remove the top
cover of the chassis. If users need to install or remove any device in the
IPC-623, they should consult qualified technical personnel.
IPC-623 User's Manual